2.13 ozs per 

minute = 1 GPH

KEY's Storage

Location

c

alibrate

 

the

 f

low

 r

ate

The Flow Rate (at full open) is pre-set to 3.5 GPH

This flow rate can easily be changed to achieve customer's desired 

output. Outputs usually vary based on the treatment time. The 

most common ones are:

 

2 to 3 GPH ~ Overnight Treatments

 

up to 5 GPH ~ Time Sensitive Treatments

 

Min/Max range is .75 to 11.25 GPH (60Hz unit).

 

Min/max range is .75 to 8.25 GPH (50Hz unit).

Optional, connect an appropriately - sized metering pump to feed  

regulate chemical product.

To calibrate a New (fully open) Flow Rate

Fill the unit's tank with water. Remove the Fan Housing and Blade 

Assembly to expose the Feed Tube (See 

Fig. 3

).

Use a measuring cup and turn on the feed pump (lower switch) for 60 

second interval while catching the water from the feed tube. Multiply 

ounces of water by 60 and then divide by 128. This will give you your 

GPH rate. Use the Key on the internal valve to make changes.
 

Example: 1 minute/ (4.2 ozs. x 60 ÷ 128 = 2 GPH)

The KEY is needed to make changes

You will need the KEY located on the side of the electrical control 

box to make changes (see 

Fig. 3

). Slide this key on top of the flow 

valve's stem (see 

Fig. 4

) to make your adjustment.

Remove KEY from valve

Regular cleaning and/or maintenance inside the tank will likely 

move the setting and cause problems to your pre-set flow rate.

Fig. 3

AUTOMATIC PRIMING OF THE SYSTEM 

OCCURS THROUGH THE FLOW RATE VALVE. 

NOTICE

f

low

 r

ateS

6

M

AQU

AFOG

Flow Rate

Valve

Flow Rate

Valve KEY

Fig. 4

Capture & Measure 

Water Output

Feed Tube

LOW FLOW, Feed Tube

Colored

Insert

HIGH FLOW, Feed Tube

Low Flow Tube comes pre-installed

The low flow feed tube has higher precision calibration 

capability at low flow rates. The low flow tube can be 

identified, having a colored insert factory installed.

High Flow Tube (provided)

Is suited for high flow applications, switch the unit 

to the high flow feed tube. To install, disconnect 

power supply, and remove the housing and fan blade 

assembly to gain access to the feed tube. Maintain the 

same angle of the factory installed tube and secure.

Output Range:

@  60Hz      .75  -  3.75      GPH
@  50Hz      2.8  -  14.0      LPH

Output Range:

@  60Hz      2.0  -  11.25      GPH
@  50Hz      7.6  -  31.2         LPH

Содержание XE CRSM

Страница 1: ...derstand Retain for Future Reference XE MOBILE ATOMIZER USER S MANUAL AND OPERATING INSTRUCTIONS OPERATOR S MANUAL NOTICE Rear Feed UL and CSA Electrical Components XE CRSM MODEL 115V 60Hz 1Ph 240V 50...

Страница 2: ...INDICATES IMPORTANT INFORMATION THAT IF NOT FOLLOWED MAY CAUSE DAMAGE TO EQUIPMENT WARNING CAUTION NOTICE Notes Description Aquafog CRSM mobile units are intended to condition large volumes of air by...

Страница 3: ...EVERallowchildrenin the work area 7 Use of an extension cord for the CRSM is not recommended If necessary refer to the A W G chart in the following section or consult a certified electrician 8 Before...

Страница 4: ...G USE OF AN EXTENSION CORD IS NOT RECOMMENDED IF NECESSARY REFER TO FIG 12 NOTICE 4 EXTENSION CORD SPECIFICATIONS FOR SINGLE FAN USE ONLY AWG American Wire Gauge Voltage 25 to 50 ft 50 to 100 ft 115 2...

Страница 5: ...ds of time At the base of the plumbing is an in line strainer with a removable cap Occasionally check inside and flush any sediment from the screen The Hose Connection is used to supply fresh water to...

Страница 6: ...H The KEY is needed to make changes You will need the KEY located on the side of the electrical control box to make changes see Fig 3 Slide this key on top of the flow valve s stem see Fig 4 to make y...

Страница 7: ...ounds of chemical needed per acre B Ounces of chemical per 100 gallons of water applied by conventional spray nozzles If A Convert the pounds into ounces Divide the ounces by 4 36 43 560 sq ft per acr...

Страница 8: ...Pivot Fogging Head Up Pivot the fogging head upward into large open air space away from the foliage If greenhouse is equipped with Horizontal Airflow Fans HAF simultaneous operation of CRSM and HAFs...

Страница 9: ...ickling out of stationary blade assembly 4 In a small bucket thoroughly pre mix the chemical with some water 5 When Ready Slowly pour the pre mixed chemical into the tank s agitated water 6 Replace th...

Страница 10: ...if a film of calcium or mineral deposits is visible on the exterior of the blades Remove any build up from the blades and any debris from blade passageways While cleaning inspect for irregularities o...

Страница 11: ...y closed position the automatic priming will not occur resulting in trapped air and poor inconsistent fogging output E Consistency of fogging output greatly depends on the consistency of the cleaning...

Страница 12: ...the slot betweenthemotorshaftandthestainlesssteelfaceplate Centeredintheslotareaand aimed slightly downward free from any rotational contact B Liquid not traveling through the fan blades This can be d...

Страница 13: ...ST 8 58 5 16 flat washer SST 12 114 Drain fitting nut 1 115 Drain gasket 1 116 5 16 18 finish nut SST 4 117 1 4 20 x 5 8 HH bolt SST 4 308 XE blade tip setscrew SST 3 349 5 16 brass rod 1 391 Top pivo...

Страница 14: ...p pivot plate Rear of Housing To Feed Pump 14 16 52 600 L 117 54 20 49 58 56 32 58 57 56 57 116 349 403 391 392 56 394 395 32 479 20 600 R Motor s Junction Box 576 7 523 522 35 To Circulation Pump 434...

Страница 15: ...1 84 45 71 C 72 65 295 295 W 14 65 65 84 45 198 67 65 Tank s Wall Inside Tank CRSM Tank Exploded View 232 207 86 423 423 75 171 173 143 3 8 tube fitting provided for optional connection to metering pu...

Страница 16: ...oupling 1 111 Axle SST 1 126 1 4 lockwasher SST 4 143 1 4 NPT M x 3 8 tube fitting 1 154 1 4 20 finish nut 4 155 1 4 NPT M x 1 2 compression fitting 1 156 Circulation tube 1 157 8 32 x 3 8 Phillips RH...

Страница 17: ...on Denotes Termination Note All green wires go to ground Denotes Line Connection Denotes Termination 240 Volt 1 Phase 50 Hertz Foreign N mtr FAN mtr PUMPS SPST TGS 115 VAC LINE SPST TGS On 2 4 5 1 3 8...

Страница 18: ...ck of maintenance or unauthorized repairs or alterations which affect the machine s performance or reliability LIMITATIONS OF LIABILITY TO THE EXTENT ALLOWABLE UNDER APPLICABLE LAW JAYBIRD MANUFACTURI...

Отзывы: