AQUALOGIC 2000™ MONITORING SYSTEM
:
The Aqualogic 2000™
has the capability to display continuously the level of irradiance
detected by the sensor in irradiance units (µW/cm
2
) or in percentage value (%). Reading
can be measured and displaced in either Absolute (0-5000µW/cm
2
) or Relative (0-100%)
by the DIPswitch SW7-8.
In addition, the Aqualogic 2000™
also reports the current temperature value of the water
either in degrees Celsius or Fahrenheit by the DIPswitch SW7-6
PROCEDURE FOR SETTING THE AQUALOGIC 2000™
1)
Gradually start the normal flow rate.
2)
Bring the unit up to normal operating pressure and temperature.
3)
Turn on the UV lamps – wait a minimum of 15 minutes.
4)
Set the “SET100% LEVEL”
See page 25.
F
IG
. A
A
QUALOGIC
2000™ S
TATUS
D
ISPLAY
B
OARD
–F
RONT
Elements to identify the Status Display Board are:
See Fig. A above.
1. Running Time LED Indicator
2. Cycle and Hour Display
3. Cycle Mode LED Indicator
4. Lamp Status Indicator-Red Lamp
“not operating”
5. Lamp Status Indicator-Green Lamp
“operating”
6. Lamp Operation Indicator
7. Low UV Intensity Indicator
8. UV Intensity and Temperature Display
9. High Temperature Indicator
10. Lamp Out Alert Indicator
1
2
3
5
6
7
8
9
4
10