background image

TM Reverse Osmosis Water Filtration System

 

Product Code: SYS-RO924TM5 

Page 

6

 of 

15

 

 

INSTALLATION PROCEDURE

 

Important Note: Do not cut the BLACK tube when installing this system.  

1.

 

Find a convenient location:  The System dimensions are 360W x 430 H x 320 D (mm), and the tank dimensions are 244 D x 
366 H  (mm). The tank can go laying down as well as the system.  

2.

 

Shut Off the water supply:  Locate the connection between the kitchen tap & cold-water line (Usually a flex line). Shut off the 
incoming water and open the tap (cold water) to release the pressure. 

3.

 

Disconnect the cold water braided hose:  If you do not know which one is the hot or cold, run the hot water for a while and 
feel the hoses. 

FEEDING THE SYSTEM WITH HOT WATER, WILL DAMAGE THE SYSTEM 

4.

 

Install the mains adaptor: From the cold-water inlet, install the valve adaptor/mains connector in 
between. DO NOT apply thread tape to these connections as they are designed to use the 
washers only. (Fig 2) 

5.

 

Check for leaks: With the blue handle facing in line with the cold-water line (As pictured) 
the valve is in the off position. During this point, you can turn the water back on to check 
for leaks in the valve installation. 

6.

 

Select location on kitchen sink to install faucet. Make sure there is adequate access under 

the  bench  top  for  the  hoses. The  faucet  supplied with  the system requires  a  ½”  (12  mm) 

hole. Use a centre punch to locate the position to drill.  

7.

 

Drill a pilot hole and gradually enlarge until you have the correct size hole.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

8.

 

To install faucet, insert the faucet into the hole in sink or bench. The faucet may be installed on any flat surface over 50mm 

(2”) in diameter. (Remember: check the underside of the location for interference). Make a small indent using a centre punch 

to mark the desired drilling location. Drill a pilot hole with a metal 

drill. Enlarge the hole using a 1⁄2” metal drill bit.

 

 
Once the hole has been drilled install the faucet as per Figure 4. Be sure the faucet body, chrome plate, and the black rubber 
washer are placed above the sink. Install the black locating washer, the lock washer and nut underneath, then tighten firmly 
while aligning faucet in the desired direction. 

Connect BLUE tube to faucet. (Fig 4)

 

Figure 3 

Figure 4 

Figure 2

 

Содержание SYS-RO924TM5

Страница 1: ...rse Osmosis Water Filtration System Product Code SYS RO924TM5 Page 1 of 15 WARNING For correct operation installation it is essential to observe these instructions TM REVERSE OSMOSIS WATER FILTRATION...

Страница 2: ...lation 4 Installation requirements 4 Typical Installation 5 Installation Procedure 6 Cartridge Installation Maintenance 8 Membrane Service Maintenance 9 Alkalising Inline Service Maintenance 9 Faucet...

Страница 3: ...ockist Customer Service Helpline 08 6156 0220 Australia OPERATION The AquaCo reverse osmosis systems are designed to run economically for many years dependent on the initial installation and periodica...

Страница 4: ...ded is a control valve incorporating backflow prevention anti hammer flow control and pressure limiting capabilities in full compliance with the relevant laws INSTALLATION REQUIREMENTS 1 13 mm Cold wa...

Страница 5: ...ter Hose Not included PLV Pressure Limiting Valve Housing Sump with 1st Stage Filter Sediment Pre Filter Housing Sump with 2nd Stage Filter Carbon Block Auto Shut Off Valve 1 4 Male Elbow Membrane Hou...

Страница 6: ...ith the cold water line As pictured the valve is in the off position During this point you can turn the water back on to check for leaks in the valve installation 6 Select location on kitchen sink to...

Страница 7: ...vercome the inlet water pressure and the shut off valve will activate shutting off the inlet water To check this check if water is running to drain Once tank is full no water should run to drain To fl...

Страница 8: ...ng housings place a container underneath to catch any spillage See Fig 7 Figure 7 4 Cleanse the inside of the housing using warm water Check O ring and lubricate with food grade silicone lubricant or...

Страница 9: ...then turn on the faucet letting the air out of the system and flushing the membrane Repeat the flushing process at least one time waiting at least 2 hours between each procedure ALKALISING INLINE SER...

Страница 10: ...13 2 Install battery into the battery seat positive side up discard plastic insert Figure 12 3 Reinstall battery seat assembly into the faucet lever battery side facing outwards 4 Blue light flashes d...

Страница 11: ...ing to local plumbing codes on the cold water line Replacement Cartridges See Cartridge replacement section This system requires regular replacement of the filter cartridge to maintain proper operatio...

Страница 12: ...t Stage Sediment Filter PP 925 1 2nd Stage Carbon Filter CB 925 5 3rd Stage 75 GPD Membrane MEM 75GPD 4th Stage Carbon Filter CB 925 5 5th Stage Alkalising Filter IL 1125BB ALK TO MAINTAIN THE HIGH QU...

Страница 13: ...orine Reduction 95 45 000 L 0 75 gpm Initial _P 5 0 psid 0 75 gpm Carbon Weight 0 80 lbs Carbon Type Activated Carbon NOTES CHLORINE REDUCTION CAPACITY BASED ON LABORATORY TESTING CONDUCTED USING TEST...

Страница 14: ...from date of purchase The 5 year warranty comprises 1 year in parts and labour plus 4 years in parts only To make a claim under the warranty take the product and proof of purchase to place where you...

Страница 15: ...provided in addition to other rights and remedies you have under law Our goods come with guarantees which cannot be excluded under the Australian Consumer Law You are entitled to replacement or refund...

Отзывы: