background image

TM Reverse Osmosis Water Filtration System

 

Product Code: SYS-RO924TM5 

Page 

3

 of 

15

 

 

INSTALLATION AND OPERATION MANUAL 

 

AQUACO CUSTOMER SERVICE

 

 

Thank you for purchasing an AquaCo reverse osmosis water filter system. Your system is a proven performer manufactured from 

only quality materials and components and will give years of ‘spring fresh’ water free of impurities if maintained properly. 

 

Caution: Do not use with water that is microbiologically unsafe or with water of unknown quality without adequate disinfection 
before or after the system.  

The system is designed for metropolitan supply water but can be used in other situations. For other types of water supply please 
contact your local AquaCo stockist or call our AquaCo Customer Service Helpline.  

The AquaCo filter systems cartridges need replacing regularly to maintain optimum performance. This is a simple procedure when 
following instructions. For cartridge replacements contact your nearest AquaCo stockist.  

Customer Service Helpline 08 6156 0220 (Australia). 

OPERATION

 

 

The AquaCo reverse osmosis systems are designed to run economically for many years, dependent on the initial installation and 
periodical maintenance.  

Flush systems for 10 minutes after any period of non-use more than 2 days. For a period of non-use of 2 weeks or more, it may be 
necessary to replace cartridges.  

This product must be installed in accordance with local plumbing regulations by a licensed plumber.  

Intstallation Note: 

A water filter system/tap, like any product, has a limited life and may eventually fail. Also sometimes failure 

happens early due to unforeseen circumstances. To avoid possible property damage, this product should be regularly examined for 
leakage and/or deterioration and replaced when necessary. A drain pan, plumbed to an appropriate drain or outfitted with a leak 
detector, should be used in those applications where any leakage could cause property damage, and/or the water supply should be 
turned off if no one is home/present. 

INSTALLATION MUST BE COMPLETED BY A LICENCED PLUMBER. FAULTY OPERATION DUE TO UNQUALIFIED PERSONS WILL 
RESULT IN VOIDED WARRANTY COVERAGE. 

 

 

 

Содержание SYS-RO924TM5

Страница 1: ...rse Osmosis Water Filtration System Product Code SYS RO924TM5 Page 1 of 15 WARNING For correct operation installation it is essential to observe these instructions TM REVERSE OSMOSIS WATER FILTRATION...

Страница 2: ...lation 4 Installation requirements 4 Typical Installation 5 Installation Procedure 6 Cartridge Installation Maintenance 8 Membrane Service Maintenance 9 Alkalising Inline Service Maintenance 9 Faucet...

Страница 3: ...ockist Customer Service Helpline 08 6156 0220 Australia OPERATION The AquaCo reverse osmosis systems are designed to run economically for many years dependent on the initial installation and periodica...

Страница 4: ...ded is a control valve incorporating backflow prevention anti hammer flow control and pressure limiting capabilities in full compliance with the relevant laws INSTALLATION REQUIREMENTS 1 13 mm Cold wa...

Страница 5: ...ter Hose Not included PLV Pressure Limiting Valve Housing Sump with 1st Stage Filter Sediment Pre Filter Housing Sump with 2nd Stage Filter Carbon Block Auto Shut Off Valve 1 4 Male Elbow Membrane Hou...

Страница 6: ...ith the cold water line As pictured the valve is in the off position During this point you can turn the water back on to check for leaks in the valve installation 6 Select location on kitchen sink to...

Страница 7: ...vercome the inlet water pressure and the shut off valve will activate shutting off the inlet water To check this check if water is running to drain Once tank is full no water should run to drain To fl...

Страница 8: ...ng housings place a container underneath to catch any spillage See Fig 7 Figure 7 4 Cleanse the inside of the housing using warm water Check O ring and lubricate with food grade silicone lubricant or...

Страница 9: ...then turn on the faucet letting the air out of the system and flushing the membrane Repeat the flushing process at least one time waiting at least 2 hours between each procedure ALKALISING INLINE SER...

Страница 10: ...13 2 Install battery into the battery seat positive side up discard plastic insert Figure 12 3 Reinstall battery seat assembly into the faucet lever battery side facing outwards 4 Blue light flashes d...

Страница 11: ...ing to local plumbing codes on the cold water line Replacement Cartridges See Cartridge replacement section This system requires regular replacement of the filter cartridge to maintain proper operatio...

Страница 12: ...t Stage Sediment Filter PP 925 1 2nd Stage Carbon Filter CB 925 5 3rd Stage 75 GPD Membrane MEM 75GPD 4th Stage Carbon Filter CB 925 5 5th Stage Alkalising Filter IL 1125BB ALK TO MAINTAIN THE HIGH QU...

Страница 13: ...orine Reduction 95 45 000 L 0 75 gpm Initial _P 5 0 psid 0 75 gpm Carbon Weight 0 80 lbs Carbon Type Activated Carbon NOTES CHLORINE REDUCTION CAPACITY BASED ON LABORATORY TESTING CONDUCTED USING TEST...

Страница 14: ...from date of purchase The 5 year warranty comprises 1 year in parts and labour plus 4 years in parts only To make a claim under the warranty take the product and proof of purchase to place where you...

Страница 15: ...provided in addition to other rights and remedies you have under law Our goods come with guarantees which cannot be excluded under the Australian Consumer Law You are entitled to replacement or refund...

Отзывы: