TM Reverse Osmosis Water Filtration System
Product Code: SYS-RO924TM5
Page
9
of
15
MEMBRANE SERVICE/MAINTENANCE
1.
Disengage tubings from the membrane housing
cap.
2.
Disengage the housing and locate your membrane
spanner and open the Membrane Housing.
Membrane housing cap can be unscrewed by
hand.
3.
Remove the cap on the membrane housing and by
using a pair of needle nose pliers remove the
membrane with a twisting motion and discard the
Membrane.
4.
To connect the new filter membrane, remove membrane packaging, only remove the outer shrink-wrap packaging, DO NOT
remove any other packaging from the membrane.
5.
When installing the new membrane, please double check that the new membrane and the old membrane have the same
specifications (part number).
6.
Check the flow arrow in the new membrane and place the new membrane in the position as the previous membrane was.
7.
Once the membrane is in the right position, INSERT THE NEW MEMBRANE
8.
To make sure the membrane housing is fully sealed, you may use plumbers’ silicone grease to lubricate the O
-ring and the
main seal. Screw in the membrane housing cap, and engage the membrane housing to the system. Then, connect the
tubing. Push the tubes as far as they can go.
9.
The process of flushing the membrane takes a bit more time. Turn on the water supply and the RO tank, allowing the
system to refill it. Wait about two hours, then turn on the faucet letting the air out of the system and flushing the
membrane. Repeat the flushing process at least one time, waiting at least 2 hours between each procedure.
ALKALISING INLINE SERVICE / MAINTENANCE
1.
Locate your isolating valve connected to your cold-water supply. Turn isolating valve OFF.
2.
Locate the tap on top of you tank. Turn the tap on top of your tank OFF. Go to your drinking faucet and open the tap to
release the pressure.
3.
Locate the filter cartridge to be replaced, and disconnect the hoses connected to that filter.
Note: Before disconnecting please check the flow arrow and specifications in the current filter to place the new filter in the correct
position.
4.
To disconnect the hose/tube, first remove the red clip. Use two fingers to push into the collet and at the same time pull out
the tube. Repeat the same process to disconnect the hose at the other end of the filter cartridge. Then, remove and dispose
the filter cartridge.
5.
To connect the new filter cartridge, remove any protection that the filter may have at the ends.
Note: When installing the new filter, please double check that the new filter and the current filter have the same specifications (part
number).
6.
Check the flow arrow in the new filter and place the new filter in the position as the previous filter was. Once the filter is in
the right position, push the tube as far as it can go and secure with a John Guest Clip.
7.
Repeat the step 6 to connect the other end of the new filter cartridge.Repeat the same process for any filter cartridge
replacement.
Figure 10