TRANSPORTATI ON AND RAISI NG
During transportation, pumps have to be adequately secured and packaged to protect the contents against accidental hits, falls, or exposition
to humidity. A particular attention is recommended to the pump connection.
Before than transport, oil must be drainer. Every AQUA pump is supplied with a 250 cc plastic bottle. However, after the first opening, the cap must
be sealed with adhesive tape for a perfect lightening.
Standard version (manual adjustment) of PDM metering pumps does not weight above 15kg, therefore can be moved by hand. In case of special
executions, please use an adequate device (trans pallets, forklift, tackle etcetera) according of packages dimension and weight.
ATTENTION: NEVER grab the pumps from their connections! This can damage the pump irreparably and cause leaks and
malfunctions!
STANDARD PACKAGE
Each AQUA pump is packed into a carton box with an appropriate protection guaranteed by a foam system, which completely envelop the
machine during its transport and movement.
DESCRIPTION
PDM metering pumps are composed of:
•
A single-phase or tree-phase alternative current electric motor;
•
A reduction gearbox which determinate pump stroke/min;
•
A liquid end chemically compatible with the pumped fluid;
•
A stroke adjustment knob, from 0 to 100% to requested flow rate.
DATA ST ICKER
Each pump comes with a sticker fixed on the pump body, like the one shown in the below picture:
1 =
Pump code
2 =
Max guaranteed flow rate (l/h)
3 =
Max working pressure (Bar)
4 =
Pump serial number.
5= Made in
– CE marking
ATTENTION: Keep the data sticker in good reading condition, protecting carefully.
•
Mentioned data are mandatory in case of spare parts request, maintenance informations or technical assistance.
•
Never remove the sticker by its original position .
•
Never edit or falsify the data mentioned in the sticker.
Liquid end materials are indicated as per the below chart, in case of special executions.