background image

 

Operating manual 

AQUA S.p.A. 

ENGLISH 

Page 22 

 

Excessive gearbox or motor heating 

 

Wrong electrical connections.  

 

Check the electrical 
connections and motor 
absorption level.  

 

Real working pressure higher 
than the max admitted 
pressure.  

 

Install a manometer on delivery 
pipe and check for the real 
delivery pressure. In case, 
reduce the pressure to 
admitted value. 

 

Delivery pipe contains section 
reductions that consistently 
increase the working pressure.  

 

Reduce the working pressure 
or install a pulsation dampener 
to stabilize it and eliminate 
pressure peaks.  

 

Pipes transmit vibrations to 
pump connections  

 

Reduce the working pressure 
or install a pulsation dampener 
to stabilize it and eliminate 
pressure peaks. 

 

Obstructed delivery pipe or 
closed by interception valve.  

 

Check the delivery valve.  

 

Counter pressure valve set as 
an higher than admitted 
pressure.  

 

Check the counter pressure 
valve set.  

 

Oil level too low or chemically 
contaminated. 

 

Check and in case replace the 
oil 

DECOMMITIONING, DISPOSAL AND DEMOLITION  

DECOMMITIONING  

Before  removing  the  pump  from  the  plant,  carefully  follow  the  instructions  at  paragraph 

7.3  “PRECAUTIONS  BEFORE  MAINTENANCE

”.  Pay 

particular attention when washing the pump wetted parts: pump-head and valve groups.  

  Capillary  wash  the  liquid  end  in  contact  with  the  pumped  product  with  compatible  substances  utilizing  an  adequate  protection. 

ATTENTION!  Product  remains trapped  in  the liquid  end  when  the machine is  stopped. Therefore  for  a  good  cleaning it  is  necessary  to 

dismantle the valve groups and clean the pump head separately. Alternatively the washing flux must be directed trough the suction valve 

with the same direction of the pumped fluid when the pump works. 

DISPOSAL AND DEMOLITION 

Pumps are composed by some metallic and plastic parts, and has an electric motor. Gearbox contains oil and it is painted with a dust base paint It is 
user  responsibility  to  respect  every  local  procedure  and  regulation  for  a  correct  disposal  and  demolition  regards  all  further  waste  created  during 
machine maintenance, disposal or demolition. 

Missing observance of this rules can provide administrative or criminal penalties

Before demolishing a pump or dismount for a parts disposal:  
 

1. 

Carefully follow instructions in paragraphs  

7.3

 and 

9.1, 

 paying particular attention t the liquid end cleaning and connections. 

2. 

Completely drain the oil removing the drin plug and recover it into the supplied oil container or in an adequate alternative.  

3. 

Carefully clean the internal of the gearbox with appropriate products ensuring to remove all present oil traces. 

   

Only  if  accurately  cleaned, 

maintenance  or  demolition  waste  can  be  considered  “special  wastes”.  Otherwise  they  have  to  be 

threated like “dangerous wastes”  

  It is absolutely forbidden to mix several types of wastes!!  

  Avoid environment or sewer release of products.  

 
To preserve the enviroment AQUA reccomeds to separe all machine components, clean, ad leave them to specialized recycling consortiums and 
companies. PDM components are listed in the following chart:  

POS. 

MATERIAL 

NORMATIVE SIMBOL/CODE 

NOTE 

 

101 (Electric motor) 

Copper and other materials 

RAEE 160216 

Electric Motor 

502, 121 

Polypropylene 

 

 

126 

Polyamide 

 

Side shell 

130 

Polyamide/Aluminum 

 

Pump body (for pumps with diaphragm size 

80 and 110 mm, consider polyamide pump 

body, for 170 mm diaphragm size consider 

aluminum pump body) 

Содержание MSA Series

Страница 1: ...USE AND MAINTENANCE MANUAL FOR DIAPHRAGM ACTUATED MOTOR DRIVEN DOSING PUMPS SERIES MSA MSB MSC ...

Страница 2: ...EN USE 10 FLOWRATE ADJUSTMENT SYSTEM 10 MANUAL ADJUSTMENT WITH KNOB AND LINEAR VERNIER 10 TECHNICAL DATA 10 INSTALLATION 11 GENERAL INDICATIONS 12 CONNECTION TO PLANT PIPES 12 ELECTRIC MOTOR CONNECTION 12 HYDRAULIC PART INSTALLATION 13 SUCTION PIPE 14 PROTECTION BY IMPURITIES 16 LIQUIDS WHIT GAS EMISSIONS 16 CALIBRATION POT 16 DISCHARGE PIPE 16 SAFETY VALVE 17 PULSATION DAMPENER 18 MANOMETER 18 ST...

Страница 3: ...further questions consultation in case of needs In order to allow easy recognition of important indications it is recommended to maintain this manual in good conditions eventually replacing it as like the following alerts present directly on the machine Machine data sticker Arrow indicating motor rotation direction Maintenance and service stickers RESPONSABILITY LIMITATIONS Missed observance of ru...

Страница 4: ...Operating manual AQUA S p A ENGLISH Page 4 ...

Страница 5: ...o risks during normal use ATTENTION In any case PDM metering pumps ARE NOT suitable for use in zone 0 20 or 1 21 SAFETY VALVE ATTENTION Diaphragm metering pumps are volumetric pumps that MUST HAVE an external safety valve installed on the discharge pipe to protect against overpressures Working pressure can t in any case be above the max admittable pressure indicated on the pump sticker even during...

Страница 6: ...ate it with additional heat TRANSPORT MOVEMENT AND STORAGE RECEIVEMENT CHECK AQUA metering pumps are supplied packaged with materials which protect them against accidental damages during transportation In any case during the reception of the package Customer should have to verify package integrity Eventual damages must be notified to the transporter and added to the Transport Document Notes In cas...

Страница 7: ...RD PACKAGE Each AQUA pump is packed into a carton box with an appropriate protection guaranteed by a foam system which completely envelop the machine during its transport and movement DESCRIPTION PDM metering pumps are composed of A single phase or tree phase alternative current electric motor A reduction gearbox which determinate pump stroke min A liquid end chemically compatible with the pumped ...

Страница 8: ...L SS316L FPM PP B4 PP CERAMIC PVC EPDM PP B5 PP PTFE PVC EPDM PP B6 PP SS316L SS316L EPDM PP B7 PP SS316L SS316L SILICON PP B9 PP HASTELLOY INCOLOY EPDM PP FF PVDF PTFE PVDF PTFE PVDF F1 PVDF CERAMIC PVDF PTFE PVDF F5 PVDF HASTELLOY PVDF PTFE PVDF AA SS316L SS316L SS316L FPM PP A0 SS316L SS316L SS316L EPDM PP A1 SS316L SS316L SS316L PTFE PP A2 SS316L SS316L SS316L FPM SS316L A3 SS316L SS316L SS316...

Страница 9: ...the pump and depends by pump type and dimensions liquid nature and viscosity and working pressure USE RESTRICTIONS Admittable project temperature Ta for all pump types is comprehended between 10 C and 40 C Maximum temperature of pumped fluid depends by the liquid end material as well as the fluid own characteristics NOTE Periodically check the respect of temperatures limits Motor power mentioned i...

Страница 10: ...den To use the pumps without Safety devices or with the same tampered or out of order To Use STANDARD version pumps in ATEX areas To use PDM pumps in ATEX version in 0 20 1 21 explosive zones FLOWRATE ADJUSTMENT SYSTEM PDM pumps flow rate adjustment is continuous and regular and can be modified with pump working or steady However it s easier to adjust when the pump is working especially for pumps ...

Страница 11: ... AQUA S p A ENGLISH Page 11 Max flow rate data refers to test with water ambient temperature of 25 C height of 250m a s l suction height of 1mt with rigid suction pipes Values are valid for operation 50Hz INSTALLATION ...

Страница 12: ...ed before connecting the pump to the pipings with special attention to suction pipe and relevant supply tank This procedure will eliminate any solid residues which if lead into the pump head can irreparably damage the pump ELECTRIC MOTOR CONNECTION For ATEX executions refer only to ATEX specific manuals in attachment to the supply Electric motor usually supplied with PDM pumps is a three phase mot...

Страница 13: ...ill be installed independently from what mentioned in this manual Here below you can find a general installation scheme Metering Pump Safety valve Pulsation Dampener Calibration pot Manometer Foot filter valve 3PH MOTOR COLLEGAMENTO A STELLA 1PH MOTOR ROTAZIONE SENSO ORARIO 1PH MOTOR ROTAZIONE SENSO ANTIORARIO 3PH MOTOR COLLEGAMENTO A TRIANGOLO ...

Страница 14: ...uptions Take special attention to perfect seals tightening Maximum liquid velocity can t exceed 0 7 m s for viscosity until 100cPs Inner diameter of suction pipe must be chosen considering pump flow meter according to the below chart Maximum pump flow rate l h Nominal recommended Ø Qmax 15 Ø 6 mm 15 l h Qmax 30 Ø 10 mm 30 l h Qmax 125 Ø 16 mm 125 l h Qmax 155 Ø 20 mm 155 l h Qmax 260 Ø 25 mm 260 l...

Страница 15: ... OF MULTIPLE PUMPS SUCTION PIPE MUST BE OVER DIMENSIONED ALSO INSTALL A VALVE THAT ALLOWS TO DRAIN THE PLANT WHEN NEEDED PUMPS UN PRIME BEFORE REACHING THE TANK MINIMUM LEVEL INSTALL AND KEEP SUCTION PIPE UNDER THE TANK MINIMUM LEVEL PUMPS UN PRIME BEFORE REACHING THE TANK MINIMUM LEVEL TO AVOID AN OSTACLE PUMP SUCTION MUST BE CONSIDERED A PRIORITY ...

Страница 16: ...her gas escape toward tank side CALIBRATION POT Installed on suction pipe derivate between tank and pump allows the calibration of actual pump flow rate in service during the normal use DISCHARGE PIPE Piping route must be as linear as possible and independently supported to avoid that weight or thermal expansions would cause deformation or excessive stress on the pump It is recommended to install ...

Страница 17: ...conveyed in a tank to allow an immediate leaking alert Even in case of free discharge a safety valve installation is recommended to avoid high pressure excesses caused by Freezing obstruction or pumped chemical solidification Viscosity variations of the fluid e g due to temperature variations Accidentally flexible piping crushing Any other unpredictable risk which may create quick and uncontrollab...

Страница 18: ...otected against external agents like sand dust corrosive substances water vibrations tensions humidity or extreme thermic excursions STARTING SEQUENCE 1 Load the oil into the gearbox using the 250 cc container supplied with the machine through the loading cap like shown in the picture However the right level matches about with the middle of the oil level plug 2 Set the adjustment at 0 and start th...

Страница 19: ... and discharge interception valves then empty the liquid end and piping parts in communication with any parts of liquid Waiting until the pump cools down ATTENTION Electric motor surface temperature may exceed 50 C during normal use Capillary wash the liquid end in contact with the pumped product with compatible substances utilizing an adequate protection ATTENTION Products remains trapped in the ...

Страница 20: ...os 115 recovering it in the bottle supplied with the machine or in another adequate container 3 Remove O ring Pos 132 4 Set the adjustment to 0 by turning the knob A to allow the advancement of the pushing rod Pos 127 ad in this way an easy access 5 Remove the seal Pos 131 then enlarge the inner lip of the seal with a wrench and plier insert a flat screwdriver and uncap the seal rotating the screw...

Страница 21: ...quid viscosity level Replace the suction pipe with an over dimensioned Increase the external suction head Exceeding tight closing or tank without bleed Execute a hole on the top of the tank Suction pipe obstructed or close for interception Check the suction pipe Obstructed Filter Clean or replace the filter Pump valves are dirt worn or assembled in wrong way Check Cleanliness worn and correct valv...

Страница 22: ...ashing flux must be directed trough the suction valve with the same direction of the pumped fluid when the pump works DISPOSAL AND DEMOLITION Pumps are composed by some metallic and plastic parts and has an electric motor Gearbox contains oil and it is painted with a dust base paint It is user responsibility to respect every local procedure and regulation for a correct disposal and demolition rega...

Страница 23: ...for A executions 102 Galvanized iron n a 105 106 107 109 110 111 112 113 114 115 131 132 135 137 510 503 504 513 501 502 505 506 508 517 Other plastic materials Only for F executions 104 505 508 511 Glass fiber filled Polyoropylene 95 C PP 507 516 PVC Inside the gearbox Lubrificant Oil n a Attention Dangerous waste not biodegradable Can be regenerated if leaved to specialized authorizated companie...

Страница 24: ...try any dismanting or fixing n warranty covered products to avoid the warranty cover invalidation Contact pre emptively AQUA customer service to obtain informations REPAIRS TO AQUA ASSISTANCE CENTER Before sending a pump to AQUA Customer must comply with the following procedure 1 Contact AQUA to have information about the nearest assistance point to which send the pump including a short descriptio...

Страница 25: ...________________________________________________________________________ _________________________________________________________________________________________________________ _________________________________________________________________________________________________________ _________________________________________________________________________________________________________ _________...

Страница 26: ...Operating manual AQUA S p A ENGLISH Page 26 ...