background image

 

 

10 

 

HC100/N/240717/NW 

 
 

 

Disclaimer 

 

The information included in these tables has been obtained from highly qualified 
sources which we deem reliable and they are provided without any guarantee, explicit 
or implicit, concerning their exactness.

 

Conditions or methods for handling, storage and use of the material are beyond our 
control and/or knowledge.

 

For this reason and for other reasons we will not be held liable thereof and we 

expressly waive obligations of claim for damages or relating to the information 
contained herein. 

 

 

WARRANTY CERTIFICATE 

 

The  pumps  are  warranted  to  be  free  from  defects  in  work  manship  and  material  for  12  months  of 
operation starting from the delivery date to the first purchaser. 
Within the above stated period the producer will supply free of charge any part that upon examination by 

the producer or by an authorised dealer, is disclosed to have been defective in work manship or material, 
or  at  its  option,  it  will  repair  the  parts  directly  or  through  authorised  workshops  It  remains  anyway 
excluded  from  whatever  responsibility  and  obligation  for  others  costs,  damages  and  direct  or  indirect 

losses that come from the use or the not use availability, either total or partial. 

The reparation or the supply in substitution will neither extend nor renew the period of guarantee.

 They 

remain  anyway  at  charge  of  the  purchaser  the  costs  of  plant  pumps  mounting  and  disassembling, 
transport cost and using materials (filters, valves, and so on).  
 

Producer’s duties, as above, are not valid when: 

 

 

The pumps are not used according to the producer instructions as in the operating manual 

and maintenance instructions; 

 

The pumps are repaired, disassembled, modified by workshop not authorised; 

 

They have used not original spare parts  

 

The injection plans are damaged buy products that are not suitable; 

 

The electric plants have been damaged because of external causes such as whatever type 

of over tensions. 

 

AT THE END OF THE TWELFTH MONTH FROM THE DELIVERY DATE, THE PRODUCER WILL BE FREE FROM 

ANY LIABILITY AND FROM ALL THE DUTIES AS ABOVE! 

 

 
 

ENGLISH

 

                                                                                                                                        ENGLISH

 

Содержание HC 100

Страница 1: ...1 OPERATING AND MAINTENANCE INSTRUCTIONS HC 100 ...

Страница 2: ... General Rules 3 2 2 Standard accessories supplied 3 2 3 Electrical characteristics 3 2 4 Electric connection 3 2 5 Hydraulic Connection 4 2 6 Operation 4 Programming 5 3 0 MAINTENANCE 3 1 General maintenance comments 6 3 2 Periodic maintenance 6 3 4 Replacing worn parts 7 3 5 Commonly reported problems 8 Chemical Compatibility Table 9 WARRANTY CERTIFICATE 10 2 8 Dimensions 7 Connections 13 ...

Страница 3: ...ashing water The equipment has to be operated by a skilled person In case of improper functioning of the panel switch off and contact our technical department for any necessary repairs For the correct functioning it is necessary to use original spare parts and original accessories The producer refuses any responsibility in reference to break down due to tampering or the use of none original spare ...

Страница 4: ...e Strainer 1 Injection fitting 2 meters opaque PE delivery tubing 2 meters PVC clear suction tubing 2 meters PVC clear priming tubing 2 3 Electrical characteristics Power supply 230 VAC 50 60 HZ Upon request all series 115 Volt AC 50 60 Hz Only for series HC1 24 12 Volt DC 24 Volt AC 2 4 Electric connection CAUTION Verify that the earth system is perfectly functional and complies with the applicab...

Страница 5: ...ight while the other end is fitted into your chemical drum tank INSTRUCTION FOR PRIMING To prime the pump in case of high injection point pressure turn the purge knob towards you until the pump head is completely full Screw down again the knob ATTENTION If it is necessary to take the pump off the plant it is important to put the white disk in again so as to avoid any exit of the liquid contained i...

Страница 6: ...ttent RED emits every time the pump pulses The HC 100 series allows you to regulate the flow in a more precise way The output volume is controlled by adjusting the number of pulses per minute which is done using the controls on the front panel You can adjust the pump between 0 100 or 0 20 of it s maximum output The operator in this way can choose a much lower number of pulses per minute PROGRAMMIN...

Страница 7: ... aggressive chemicals are being dosed Sodium Hypo chlorite is particularly difficult this period may need to be reduced and cleaning be carried out more frequently If pumps are not used for long periods scale sediment and encrustation deposits can build up causing the pump to malfunction We highly recommend careful maintenance of the valves by running them under clean water after long periods of n...

Страница 8: ...ntly remove the cartridge 2 If a ball valve cartridge is fitted remove the whole assembly and replace with a new one taking care to ensure that the arrow is pointing in the direction of flow vertically upwards 3 If lip valves are fitted these can be replaced once again ensuring that they are refitted the correct way up with their open end downwards and the lip part in the direction of flow 4 Refit...

Страница 9: ... the injection valve is not closed 4 Effectuate a maintenance of the suction and delivery valves Parts showing any chemical attack should be replaced with alternative materials if necessary CHEMICAL LEAKS FROM THE DOSING HEAD Solutions 1 Check that the hose clamps are correctly fitted and tightened Caution do not overtighten these components as they can easily be broken or threads stripped 2 Check...

Страница 10: ... 1 Sulphuric acid 98 5 H2SO4 1 1 3 3 1 1 1 3 3 3 Amines R NH2 1 2 1 3 1 1 3 2 3 1 Sodium bisulphite NaHSO3 1 1 1 1 1 1 1 1 1 1 Sodium carbonate Soda Na2CO3 2 1 1 1 1 1 2 1 1 1 Iron chloride FeCl3 1 1 1 1 1 1 1 1 1 1 Calcium hydroxide Ca OH 2 1 1 1 1 1 1 1 1 1 1 Sodium hydroxide Caustic soda NaOH 2 1 1 1 1 1 2 1 2 1 Calcium hypochlorite Ca OH 2 1 1 1 1 1 1 1 1 3 1 Sodium hypochlorite 12 5 NaOCl NaC...

Страница 11: ...ion it will repair the parts directly or through authorised workshops It remains anyway excluded from whatever responsibility and obligation for others costs damages and direct or indirect losses that come from the use or the not use availability either total or partial The reparation or the supply in substitution will neither extend nor renew the period of guarantee They remain anyway at charge o...

Страница 12: ...11 HC100 N 240717 NW Fig 1 HC 1 WALL MOUNTING Fig 2 HC 1 BASE MOUNTING ...

Страница 13: ...12 HC100 N 240717 NW Ball valves Lip valves Fig 3 4 PUMP HEAD TUBING CONNECTIONS Purge Valve Hose clamp ...

Страница 14: ...13 HC100 N 240717 NW Fig 5 Pump parts drawing ...

Страница 15: ...YELLOW LABEL WITH AQUA LOGO 5 ADSP6000415 PTFE DIAPHRAGM 1L ADSP6000416 PTFE DIAPHRAGM 2 15L 6 ADSP6000421 PISTON FLANGE 2 6L ADSP6000420 PISTON FLANGE 5 15L 7 ADSP6000708 SCREW M 4 X 8 UNI 7688 10 ADSP6000441 TRIMMER KNOB 11 ADSP6020144 TRASPARENT COVER 12 ADSP6000121 CAP FOR LED GUIDE 13 ADSP6000120 LED GUIDE 14 ADSP6000310 HC100 CIRCUIT 230V ADSP6000329 HC100 CIRCUIT LEVEL 230V ADSP6000616 ADSP...

Страница 16: ...15 HC100 N 240717 NW ...

Страница 17: ...7020 OR 4312 DUTRAL 78 97X3 53 FOR 30 50L PUMP HEAD 29 ADSP6000723 M4 X 35 SCREW A2 TCEI 30 ADSP6000805 D04 X 10 X 1 A2 WASHER 31 ADSP5007011 SPACER D 3 2X6 45X5 5 SANT64A 32 ADSP5007113 ORM VITON D3 00 t2 00 ADSP5007114 ORM DUTRAL D3 00 t2 00 33 ADSP5007050 PYREX BALL D 4 76 3 16 ADSP5007051 PTFE BALL D 4 76 3 16 ADSP5007052 AISI 316 BALL D 4 76 3 16 ADSP5107007 CERAMIC BALL D 4 76 3 16 34 ADSP60...

Страница 18: ...5P BALL VALVE 3 8 RING NUT PVDF 48 ADSP5005001E LIP VALVE NIPPLE PP NERO 3 8 4X6 ADSP5005004 LIP VALVE NIPPLE PVDF 3 8 4X6 ADSP5005002 LIP VALVE NIPPLE PP 1 2 10X14 46 ADSP5001001 LIP VALVE VITON STANDARD ADSP5002001 LIP VALVE DUTRAL STANDARD ADSP5008001 LIP VALVE SILICONE STANDARD ADSP5001002 LIP VALVE VITON GP ADSP5002002 LIP VALVE DUTRAL GP ADSP5008002 LIP VALVE SILICONE GP 45 ADSP5007005 LIP V...

Страница 19: ...18 HC100 N 240717 NW NOTES ...

Страница 20: ...19 HC100 N 240717 NW AQUA WATER SYSTEMS LTD Unit 135 Oak Drive Hartlebury Trading Estate Hartlebury Worcestershire DY10 4JB Tel 44 0 1299 251050 www aquaindustrialgroup co uk e mail sales askaqu co uk ...

Отзывы: