2.0 TECHNICAL CHARACTERISTICS
2.1 General rules
Install the pump:
In a Vertical reinforcement (ex: Wall) or on the pump stand (optional) so that
the pump head stays always in vertical po/-15°.
Far from a hot source in dry places at maximum temperature of 45°C and
minimum 0°C.
In a ventilated place and easily accessible by an operator for periodical
maintenance.
At a suitable height above the chemical up to a maximum height of 1.5 meters.
If for xigency of the plant it’s necessary to install the pump under the level of
the chemical, you need to use an injection valve or an anti siphon valve.
Do not install the pump over the tank in presence of liquids that emanate fumes
unless it is hermetically closed.
2.2 Standard accessories supplied
1 Foot valve / Strainer.
1 Injection fitting
2 meters opaque PE delivery tubing.
2 meters PVC clear suction tubing.
2 meters PVC clear priming tubing
2.3 Electrical characteristics
Power supply: 230 VAC 50/60 HZ
Upon request (all series)
115 Volt AC 50-60 Hz
Only for series HC1
24/12 Volt DC – 24 Volt AC
2.4 Electric connection CAUTION !!!!!
Verify that the earth system is perfectly functional and complies with the applicable
regulations. Ensure the unit is connected to a circuit protected by a highly sensitive (0.03A)
RCCB circuit breaker. If unsure please consult a competent electrician. Verify that the rated
values of the pump are compatible with those of the mains. Never install the pump directly in
parallel with inductive loads (e.g. motors/solenoid valves) if necessary, use an isolating relay.
There are 2 protection devices inside the pump: a varistor and a fuse.
P- Metering Pump
R- Relay
I-
Switcher or multi-pole security device
E- Motor or generally inductive charge
A-
Supply voltage
ENGLISH
Содержание HC 100
Страница 1: ...1 OPERATING AND MAINTENANCE INSTRUCTIONS HC 100 ...
Страница 12: ...11 HC100 N 240717 NW Fig 1 HC 1 WALL MOUNTING Fig 2 HC 1 BASE MOUNTING ...
Страница 13: ...12 HC100 N 240717 NW Ball valves Lip valves Fig 3 4 PUMP HEAD TUBING CONNECTIONS Purge Valve Hose clamp ...
Страница 14: ...13 HC100 N 240717 NW Fig 5 Pump parts drawing ...
Страница 16: ...15 HC100 N 240717 NW ...
Страница 19: ...18 HC100 N 240717 NW NOTES ...