When reassembling the sump, check that the O-Ring is not deteriorated (or pinched) and that it is 
positioned correctly in its seat. 
 
If the water is not used for several weeks, it is advisable to remove the cartridge from the container. 
Before reinstalling the filter cartridge, wash it thoroughly and sterilize it, or fit a new cartridge. 
 
At the end of all maintenance operations, it is advisable to let the water run for a few minutes before 
using it. 
 
To carry out maintenance, follow the steps below: 
- Divert the passage of water from the filter, by acting on the by-pass (if present) or by closing the 
water taps; 
- Act on the screw or on the vent button, in order to reduce the internal pressure of the filter; 
- Place a low container on the floor to collect the water that will drip from the filter when it is opened, 
or some rags to collect the water; 
- Disassemble the sump using the special plastic key. Be careful not to drop the sump. It is sensitive 
to shocks; 
- Be careful not to lose the O-Ring and check that it is not damaged. Otherwise, recover a new O-
Ring; 
- Remove the cartridge and eliminate any dirt present in the vessel, inside the head or on the O-
Ring. 
- Place a new cartridge or the removed cartridge (if washable) in the sump after cleaning it, taking 
care to position the gaskets correctly, if present; 
- Screw the sump onto the head (by hand); 
- Reactivate the water network by keeping the vent valve open until all the air present in the network 
has escaped, after which close the vent valve. 
- If the filter shows dripping tighten the sump with the key; 
- Regardless of the type of cartridge used, at the end of each cleaning or maintenance operation, let 
the water run for a few minutes before using it. 
 
The frequency of intervention is linked to the type of cartridges used: 
 
CARTRIDGES FOR SEDIMENTS: (wire wound, Melt Blown, pleated, RLA, etc.): 
Replace or wash the sediment cartridges within 2-5 months, or if necessary, if a significant pressure 
drop is detected. Washable cartridges (RLA) can be used multiple times. 
They must be washed and disinfected periodically, as specified below. 
1). Wash thoroughly under running water. 
2). Immerse the cartridge in disinfectant that does not alter / corrode the structure of the cartridge 
itself, for 5 (five) minutes. 
3). Remove the cartridge from the disinfectant liquid and rinse thoroughly. 
The  polypropylene  cartridges  (Melt  Blown)  must  be  thoroughly  washed  before  installation,  to 
eliminate the residues of the antistatic compound used for processing of the fibers. 
 
CARBON CARTRIDGES: 
Replace the active carbon cartridges within 3-4 months, or if necessary if you perceive a taste of 
chlorine, bad smells or tastes. 
Before installing a new cartridge, rinse thoroughly to remove any carbon dust residues. 
 
SALT POLYPHOSPHATE: 
Replace  the  polyphosphate  salt  cartridges  within  4-6  months  or,  in  any  case,  when  the 
polyphosphate salt is exhausted. 
 

Содержание FP2

Страница 1: ...FP3 filters can contain cartridges of various kinds depending on the type of treatment to be carried out on the incoming drinking water In particular AQUA spa makes available for these filters Wire wound cartridges Mod FA Melt Blown polypropylene cartridges Mod FR E FR N FR A Washable mesh cartridges Mod RLA Pleated cartridges Mod PL Ultrafiltration cartridges Mod UF Steel cartridges Mod AC Activa...

Страница 2: ......

Страница 3: ...atment on the drinking water entering the network The filters are available with transparent sumps and opaque sumps in different heights with different pipe connection sizes with and without brass inserts and in two FP2 or three FP3 pieces WHITHOUT BRASS INSERTS WITH BRASS INSERT Their typical installation scheme is as follows ...

Страница 4: ...revent boiling water from entering the filter Do not use the containers for the filtration of compressed air oil or gas even at low pressures Do not use these filters in environments exposed to freezing temperatures or high temperatures Therefore installation outdoors or in places exposed to bad weather or ultraviolet rays is not recommended This equipment requires regular periodic maintenance in ...

Страница 5: ...the wall is 80 mm The minimum distance from the floor is 25 mm The recommended distance is instead of 100 mm or more Depending on the size of the filter purchased it is possible to determine the fixing point of the bracket using the following table where the dimensions of the FP3 filter can also be deduced Similar considerations can be made for FP2 filters The relative dimensions can be found in t...

Страница 6: ...ectly to the device Pipes can be used for welding pressure or with union Use fittings with cylindrical thread with GAS or BSP pitch Do not use fittings with tapered threads When fixing the fittings to the head avoid using sealing pastes hardening liquids silicone hemp or other but only Teflon tape After fixing open the taps and check that there are no leaks or drips ...

Страница 7: ...and remove any dust or dirt present in the filter even after its assembly After these operations the filter is running regularly These operations must be repeated every time the filter cartridge is replaced or serviced CLEANING AND MAINTENANCE ATTENTION This equipment requires regular periodic maintenance in order to ensure the potability requirements of the treated drinking water and the maintena...

Страница 8: ...head by hand Reactivate the water network by keeping the vent valve open until all the air present in the network has escaped after which close the vent valve If the filter shows dripping tighten the sump with the key Regardless of the type of cartridge used at the end of each cleaning or maintenance operation let the water run for a few minutes before using it The frequency of intervention is lin...

Страница 9: ...tem is used according to the instructions given by the manufacturer Installation and maintenance are carried out following the manufacturer s instructions The replacement under warranty is made only against the return of defective material and after verifying the nature of the defect The warranty is intended limited to the replacement of the part recognized as defective and excludes any other righ...

Отзывы: