Eradicator II AIF Systems
Installation, Operation,and
Maintenance Manual
Location Data
Sizing Information:
Hardness ______ grains per gallon
Iron ______ parts per million
pH _______
Chlorine ______ parts per million
Inlet Water Line Size ______
No. in Family _______
No. Baths _________
Bypassed Hard Water Lines:
Outside Spigots ___________
Swimming Pool Fill Line ________
Kitchen Cold _________________
Irrigation Systems_____________
Pre Install Review
Requirements for Proper Operation:
Tips:
Water Pressure:
The system requires a minimum of 20 psi
to be sustained with flowing water of 5 gallons per minute or
greater. Maximum is 125 psi.
Flow Rate:
A minimum of 5 gallons per minute is required
for proper operation. If less than 5 gallons per minute is
available, consult with your dealer for possible custom
configurations.
Water Temperature:
The range of water temperature for
these systems is 40˚ F to 110˚ F.
Drain:
A drain within 20’ of the system can be run with
1/2
” tubing. Drains running over 20’ should use
3/4
” tubing.
Maximum overhead rise should be ≤ 8’. Consult your dealer
for any drain > 30’ in length.
Special Drain Note:
The drain must be a legal connection
with a code compliant air gap. It is critical that the drain be
secured tightly at each end, and anchored throughout the run.
The AIF systems will jolt the drain line during the release of
air. Be sure to protect the immediate area from any spray
that may occur at the air gap. The drain connections should
be thoroughly tested before completing the installation.
Electricity:
An uninterrupted 110volt A.C. source is required
to operate AIF systems.
Special Electrical
Note:
You must make sure that the
power
outlet is not connected to a timer, or a switch.
Source water pH:
If the pH of the source water
is < 7, you must consult with your dealer. The
pH adjustment option must be added if pH is
below this specification.
Freezing:
The AIF system, drain, plumbing
and all other water fixtures, must be protected
from freezing temperatures. Be sure that the
installation site is not exposed to temperatures
below 32˚ F.
Positioning:
Be sure to position the AIF
system so it can be removed or accessed for
future servicing.
Outside Faucets:
Outside faucets must be
bypassed from any AIF system. These systems
are not designed for watering lawns, filling
pools, or any other outdoor use.
Sand:
If sand or sediment is present you must
install a sand separator, or sediment filter ahead
of the AIF system.
Chlorine:
AIF systems will not work on chlo-
rinated water supplies. Chlorine, and other
strong oxidizers will damage the media bed in
AIF iron filters.