Eradicator II AIF Systems
Installation, Operation,and
Maintenance Manual
Troubleshooting
24
Problem
Possible Cause
Solution
6. Control valve stalled in
regeneration
a. Motor not operating
a. Replace motor
b. No electric power at outlet
b. Repair outlet or use working outlet
c. Defective transformer
c. Replace transformer
d. Defective PC board
d. Replace PC board
e. Broken drive gear or drive cap as
-
sembly
e. Replace drive gear or drive cap assembly
f. Broken piston retainer
f. Replace drive cap assembly
g. Broken main or regenerate piston
g. Replace main or regenerate piston
7. Control valve does not
regenerate automatically
when REGEN button is
depressed and held
a. Transformer unplugged
a. Connect transformer
b. No electric power at outlet
b. Repair outlet or use working outlet
c. Broken drive gear or drive cap as
-
sembly
c. Replace drive gear or drive cap assembly
d. Defective PC board
d. Replace PC board
8. Control valve does not
regenerate automatically
but does when REGEN
button is depressed
a. By-pass valve in bypass position
a. Put bypass valve in normal operation posi
-
tion
b. Meter connection disconnected
b. Connect meter to PC board
c. Restricted/stalled meter turbine
c. Remove meter and check for rotation or
foreign matter
d. Defective meter
d. Replace meter
e. Defective PC board
e. Replace PC board
f. Set-up error
f. Check control valve set-up procedure
9. Time of day flashes on
and off
a. Power has been out and the bat
-
tery has expired, or the NEXT and
REGEN buttons were pressed to
reset the
control.
a. Replace battery (type CR2032) if it has
expired
b. Reset the time of day