***Continued on next page***
Aqua Phase
, A Division Mid-State Stainless Inc. ●
330
W.
Benson Ave. ●
PO Box 228 ●
Grantsburg, WI 54840 ●
USA
800-208-9274 ●
715-463-5851
●
FAX: 715-463-5853
● Email: [email protected] ●
DO NOT CLIMB INTO THE WASH CHAMBER
Carefully read and follow the notices and instruction labels of the de-liming solution you
will
be
using.
Drain Aqua Phase.
Remove the Rinse and Detergent hoses from the cleaning solution bottles inside the
Mechanical
Cabinet at the rear of the machine.
Set the ‘
RUN/DRAIN’
switch to “
RUN
”.
Set the mode switch to “
CLEAN
”.
Set the wash cycle time to “
7 minutes
” or the longest time cycle available.
Press the “
START
” button and allow Aqua Phase to fill.
As soon as Aqua Phase starts to spray water, press the “
STOP
” button.
•
At this point, the Aqua Phase water reservoir will be full. The Aqua Phase reservoir
holds
5.5 gallons of water.
Open the front door and pour the proper amount of deliming solution directly into the
water
that
is in the reservoir of the machine.
•
BE CERTAIN
to add the proper amount of deliming solution according to the
dilution
rate recommended by the manufacturer of the deliming solution concentrate
you are
using
(the
Aqua Phase
reservoir holds 5.5 gallons of water).
Close the front door and press the “
START
” button.
•
Allow Aqua Phase to run for no longer than 4 minutes
.
•
Press the “
STOP
” button.
Wait approximately 5 minutes.
•
Set the wash cycle time to “
7 minutes
” or to the longest time cycle available.
•
Press the “
START
” button, and allow
Aqua Phase
to run a complete cycle.
72