Warning:
Wear Protective Clothing When Working With Any Chemicals.
Warning:
Consult the material safety data sheets located in the
back of this manual and your company’s
hazardous substance policy before handling any chemicals.
Key to
Aqua Phase
chemical solution hoses:
•
The
RED
hose is for
Detergent
/
Cleaning Solution.
•
The
BLUE
hose is for
R
inse-
A
id.
•
The
CLEAR
hose is for
D
isinfectant, if installed.
1.
Place Chem
i
cal Solutioins in the Chemical Tray (located inside the Chemical Cabinet at the rear of the
Aqua Phase) as the locations marked
"DETERGENT"
and
"RINSE-AID".
2.
Remove chemcial bottle caps and place the appropriate colored hoses in bottle openings
RED
hose for
Detergent/
BLUE
hose for Rinse-Aid.
Do not dilute solutions.
NOTE: If Disinfection Application System is installed, t
he disinfect
ant
injection rate is preset at
the factory for a dilution rate of 1 oz. per gallon of water. Contact the factory if adjustment of the
injection rate is necessary.
3.
On the control panel at the front of the machine:
•
Set the "WASH TIME" switch to "3 MIN".
•
Set the “RUN/DRAIN” switch to “RUN”.
•
Set the wash mode switch to "CLEAN & DISINFECT" or "CLEAN ONLY" if
no
disinfectant
application system is installed.
4.
Close the front
door.
5.
Press the “
START
” button. The “
START
” button is located on the control panel at the front of
the
machine.
•
Allow
Aqua Phase
to run a two complete cycles before washing any items.
If
Aqua Phase
does not start, see the
"TROUBLESHOOTING: Will not start
” section of this manual or
call the factory for support.
8
BASIC SET-UP
PROCEDURES
(Continued)