12.
Press the “
START
” button and allow
Aqua Phase
to run another complete cycle.
13.
Examine and clean the Reservoir Filter Screens.
•
Repeat steps 10 – 13 until the filter(s) collect minimal debris.
•
You may select “
3 minutes
” or the shortest time cycle available when repeating Steps
10 – 13.
14.
Examine and clean the reservoir filter located inside the wash chamber reservoir.
15.
Drain
Aqua Phase.
16.
Disconnect
Aqua Phase
from power source.
17.
Shut-off the water supply to
Aqua Phase.
Other Items:
Aqua Phase
may not stop draining during Step 11 above.
The deliming solution will normally create foam inside the Wash Chamber. The foam may affect certain
sensors that control the filling and draining of water.
In Step 11 above, if Aqua Phase does
not
stop draining after a few minutes, perform the following:
a)
Press the “
STOP
” button and wait a few minutes until the foam dissipates.
b)
Press the “
START
” button and allow Aqua Phase to do a complete cycle.
c)
Repeat the preceding Steps a) and b) until Aqua Phase starts draining normally.
d)
Return to Step 11 above.
CHECK FOR DEBRIS IN THE SPRAY NOZZLES.
If your unit does not have the reservoir filter screens seated properly in their place at all times, you can
expect most of the spray nozzles to become clogged during the deliming of your machine. After you have
completed the deliming processes above, check the spray nozzles to make certain they are not clogged.