Water supplied Aqua Phase is “hard”, a lot of totally dissolved solids.
1.
WATER TEMPERATURE BELOW 105°F
:
•
Check the temperature of the water reaching the Aqua Phase.
•
Drain the Aqua Phase.
•
Press the
“START”
button. Allow the Aqua Phase to fill.
•
As soon as Aqua Phase begins to pump, press the
“STOP”
button.
•
Open the front door, place a thermometer in the Water Reservoir to check
the water temperature. Water temperature should be between 105°-130°.
•
AQ-260 Rinse-Aid Solution requires a water temperature at or above 105°
2.
THE WATER SUPPLY TO THE AQUA PHASE IS “HARD” WATER.
•
The AQ-240 Cleaning Solution, in conjunction with the spray nozzles are
in effect cleaning the water, and taking the hard water particles out of
suspension.
•
A Water Fill Assembly (5-10 Micron Cartridge) from Aqua Phase factory,
installed at the Fill Line may correct this pending the water contaminants.
•
It may be correctable, pending the pH of the water, and the totally
dissolved solids of the water to alter the injection rate of the AQ-240
Cleaning Solution to reduce the amount of solids being taken out of
suspension.
3.
RINSE-AID SOLUTION CONTAINER EMPTY
•
Check the level of rinse-aid solution, refill if necessary. The chemical
solutions are located inside the Mechanical Cabinet at the rear of the Aqua
Phase.
4.
RINSE CHEMICAL INJECTOR HOSE OR FITTINGS ARE WORN.
•
Inspect chemical hoses for cracks and inspect chemical hose fittings for
cracks or if loose.
•
Replace if damaged—you may order replacement parts by calling your
dealer or the factory.
Notes:
The solution injection rates are preset at the factory for the worst possible water condition
expected to be found.
If spotting or clouding is present only on the first item washed, it is possible that you will need to
run a “warm-up cycle” with Aqua Phase. Run a “3-minute” wash cycle with the Wash Chamber
empty to allow the Wash Chamber to be warmed-up prior to commencing normal washing
operations.
If problem persists, call the factory for assistance.
ITEMS
W
ASHED HA
V
E
W
ATER
SPOTS OR CLOUD
Y
F
ILM.
41