background image

2

water level

7

They  are  also  provided  with  multiple  outlet 
options. 

1. Duckbill or multi directional outlet: allows the 
water  to  be  channelled  a  variety  of  different 
directions.  Good  for  providing  water  flow  to 
static  areas  of  the  aquarium,  thus  reducing 
waste build up.

2.  Venturi:  for  injecting  bubbles  into  the 
aquarium. The venturi adjuster allows the water 
to air ratio to be adjusted by the user.

3.  A  19mm  barbed  hose  tail  is  also  provided 
with the 1300 series pump. This can be used for 
running devices such as protein skimmers. 

2300,  3600  and  4900  series  pumps  are 
dedicated sump pumps. They are provided with 
19mm and 25m barbed hose tails. They can be 
used for many other purposes such as running 
external  filtration  devices  or  simply  circulating 
water.      

The  360,  480  or  1300  series  Morays  can  be 
mounted  in  2  different  ways  and  used  for  a 
variety of applications. All 3 models come with 
uplift  pipe  adapters  enabling  them  to  be  used 
as an alternative to air driven systems on under 
gravel  filters.  Refer  to  the  “know  your  pump” 
section at the front of this instruction booklet for 
part identification.

1. Remove the top motor cover and the strainer.
2. Remove the 4 suction cups.
3. Insert the hang mount into the 2 holes at the 
strainer end of the motor
4. Place the top motor cover and the strainer (If 
being used) back into position.

 

1. Remove the strainer and slide the base plate 
out towards the impeller. 
2. Slide the hang mount into the groves at the 
back of the pump.
3. Replace the strainer. (If being used)

Pump Installation

Attaching the hang bracket 380/480 series 

Attaching the hang bracket 1300 series 

water level

Содержание moray 1300

Страница 1: ...Models 360 480 1300 2300 3600 4900 Moray Instruction Manual ...

Страница 2: ...sible for their safety Children should be supervised to ensure that they do not play with the appliance Warning To guard against injury basic safety precautions should be observed including the following 1 Read and follow all safety instructions before using this appliance 2 Danger To avoid possible electric shocks special care should be taken since water is employed in the use of aquarium equipme...

Страница 3: ... 17i Moray 4900 Impeller 18i Moray 1300 Sponge 12s Moray 2300 Sponge 13s Moray 3600 4900 Sponge 17s Aqua One Spare Parts 14i Carefully unpack the pump making sure you keep all the packing material until all the parts of the product have been found and the product has been assembled This product is shipped to you in a factory sealed carton Should the product malfunction in any way or if the unit is...

Страница 4: ...12mm joiner 4 Duckbill 5 Hang bracket 6 Rubber end cap 7 Impeller 8 Shaft 9 Venturi adjuster and airline 10 Impeller cover lock 11 Internal strainer 12 Uplift adapter 13 Strainer 360 480 Know Your Pump 6 1 2 7 8 3 4 5 9 10 11 12 13 ...

Страница 5: ...1 Motor 2 Hang bracket 3 Rubber end cap 4 Impeller 5 Ceramic shaft 6 Impeller cover lock 7 Internal strainer 8 Uplift adapter 9 Sponge 10 Strainer 11 Venturi outlet 12 Multi directional outlet 13 Barbed 19mm hose tail 14 Venturi adjuster and airline 1300 ...

Страница 6: ...r end cap 4 Impeller 5 Ceramic shaft 6 Impeller cover 7 Impeller lock 8 Internal strainer 9 Sponge 10 Strainer 11 Barbed 25mm hose tail 12 Threaded reducer 13 Barbed 19mm hose tail 14 Inlet elbow 2300 3600 4900 1 3 4 2 5 6 7 8 9 10 11 12 13 14 ...

Страница 7: ...al filtration devices or simply circulating water The 360 480 or 1300 series Morays can be mounted in 2 different ways and used for a variety of applications All 3 models come with uplift pipe adapters enabling them to be used as an alternative to air driven systems on under gravel filters Refer to the know your pump section at the front of this instruction booklet for part identification 1 Remove...

Страница 8: ...ect materials have been prepared and the most suitable pump position has been selected As with all water pumps the greatest flow efficiency will be created through the shortest length of pipe hose and with the fewest number of bends Avoid reducing the size of the plumbing as this will greatly reduce flow Note flow is reduced less through 2 x 45 bends than through a single 90 bend Flexible hose is ...

Страница 9: ...nstalling the unit into your aquarium or filter ensure your hand is dry and there is no water on any part of the pump which is not intended to have water on it Plug the pump in and turn on to ensure the pump is working corectly 1 Turn the pump off at the main power supply and remove it from the water 2 Remove the strainer cover from the front of the pump To do this hold the motor with one hand and...

Страница 10: ...ions specifications or this Guarantee Aqua One reserves the right to terminate Extended Guarantee for such goods and will provide written notice to the purchaser 3 0 Exclusions and Limitations Where permitted by local law the following exclusions and limitations apply in regard to the Guarantee 3 1 Goods claims where fault is due to but not limited by a misuse b neglect c abuse d fire or flood e n...

Страница 11: ...fications Notes W 220 240V 50Hz Moray 360 600 L hr 0 86m 6 5W Moray 480 720 L hr 0 96m 8 5W Moray 1300 1100 L hr 1 4m 14 6W Moray 2300 2200 L hr 2 2m 30W Moray 3600 3600 L hr 3 4m 79W Moray 4900 4800 L hr 3 6m 100W h ...

Страница 12: ... in the most efficient and superior aquarium products The Aqua One range includes a wide range of curved glass aquariums air pumps filters power heads heaters reflectors under water lighting along with fish foods cleaning and maintenance accessories and decorations Keep an eye out for these Aqua One products at your local retailer Instruction Version 18 04 09 ...