NO WATER CIRCULATION 

1. Check power supply and confirm Power 
Head is plugged in. 
2. No water in Filter Box, add water to 
Maximum Water level indicator. 
3. Check Overflow Box to confirm water is 
flowing.
4.  Check the Pre Filter at the front of the 
Overflow Box and clean if needed. 

LARGE AMOUNT OF 

BUBBLES ARE BEING 

PUMPED BACK INTO TANK 

1. Check water level in the MariSys, add water 
if needed. 
2. Check Overflow Box for obstacles. 
3. Check Hosing and Tubing for kinks or 
obstructions.
4. If using air stones or power heads with 
venturi installed, position away from Overflow 
Box inlet. 

RETURN WATER FLOW IS 

SLUGGISH.

1. Check Overflow Hosing or return Hosing for 
kinks; straighten Hosing and/or tubing if 
needed.
2. Check for obstructions in Overflow Box or 
inlet of Power Head. 
3. Check the Power Head.

POWER HEAD NOT RUNNING 

1. Check the Power Head is plugged in and 
has electrical power. 
2. Check Impeller in Power Head to confirm it 
is rotating freely. Refer the Maintenance 
section in this instruction booklet. 

WATER LEAKING AT FLEXIBLE 

HOSING CONNECTIONS 

1. Disconnect Flexible Hoses from connectors 
on the MariSys and Overflow Box and clean 
connectors thoroughly with an Aqua One 
Double Ended Pipe Brush. Reconnect and 
tighten hose clamps snugly. 
2. If the Flexible Hosing has slipped from 
original position, remove and clean area, then 
reconnect and tighten hose clamps snugly. 

PROTEIN SKIMMER NOT 

FUNCTIONING

1. If the Filter is newly set up, it may take a 
couple of days for the Skimmer to start 
collecting waste. 
2. Confirm Air Pump is plugged in. 
3. Confirm Air Pump is connected to Wood 
Airstone Rigid Airline Tubing. 
4. The Wooden airstone may need to be 
replaced.

NO FOAM PRODUCTION IN 

THE COLLECTION CUP 

1.  Aquarium is not established yet and has not 
produced enough dissolved organics. 
2. Wood airstone needs to be replaced. 
3. Skimmer is in break-in period, should work in 
3 days. 

SUDDEN OR GRADUAL LOSS 

OF AIRSTONE BUBBLES 

1. Possible clogged airline, remove airline 
tubing and run under hot water thoroughly. 
2. Wood airstone needs to be replaced. 
3. Check the Air Control Valve and Check 
Valve.  

Trouble Shooting

12

Содержание MariSys 240

Страница 1: ...MariSys 240 Complete step by step instruction booklet ...

Страница 2: ...plug or receptacle does get wet do not unplug the appliance Disconnect the fuse or circuit breaker that supplies the power to the appliance then unplug and examine for presence of water in the receptacle 3 Close supervision is necessary when the appliance is used by or near children 4 Always unplug the filter from the electrical outlet when not in use before putting on or taking off parts before a...

Страница 3: ...as been assembled This product is shipped to you in a factory sealed carton Should the product malfunction in any way or if the unit is damaged and requires replacement contact the retailer where the product was purchased for inspection Replacement Parts Filter Media Use Aqua One Genuine Spare Parts Only See your local Aqua One Dealer and look for the number listed below for the spare part you req...

Страница 4: ...bon Pad Media Basket 1 Media Basket 3 Wool x 3 Activated Carbon Pillow Media Basket 2 Bio Balls CeramiSub Drip Tray Please Note This filter media set up above is a guide For more information regarding filter media please consult your Aqua One specialist 4 ...

Страница 5: ...tein Skimmer Air Pump Fit a check valve if placed on the floor 12 Priming Pump 20 Check Valve 21 Air Control Valve 26 Protein Skimmer Height Adjuster 8 Overflow Box 2 Filter Box 19 Protein Skimmer Airline Connector 1 Media Access Lid 15 Water Bridge 27 Priming Chamber Duck Bill Outlet 28 Max 29 Min 14 V Joint 1 MariSys Complete System Diagram 1 5 ...

Страница 6: ...Basket 3 CreamiSub Carbon Pillow Airstone Stop 5 Power Head Outlet Inlet Airstone Housing 25 Reaction Chamber Lid Waste Out 10 Water Level Adjuster 11 Screw Adjuster 9 Adjusting Screws 23 Protein Skimmer Collection Cup 7 Power Cord Cutout 4 8 Overflow Box 3 Overflow Box Diagram 3 2 MariSys Diagram 2 6 Power Head Protein Skimmer Housing 6 ...

Страница 7: ...the adjusting screws anti clockwise this will reduce the height of the Overflow Box To raise the water level in the aquarium turn the adjusting screws clockwise to move the box back up Setting up the Filter Media For the following section refer to Diagrams 1 2 on pages 3 5 6 of this instruction booklet Locate and organise all parts before assembly Familiarise yourself with the parts and where they...

Страница 8: ...e should be positioned about 1 5 2cm from the bottom of the Reaction Chamber The aquarium s water level can also be raised or lowered by adjusting the Water Level Adjuster 10 Raising the tube will cause the aquarium s water level to rise and lowering the Water Level Adjuster will cause the aquarium s water level to drop 3 Remove the pre filter pad rinse it under water and place back into the Overf...

Страница 9: ...n wait 5 minutes If still too few turn the screw another quarter turn It is best to adjust slowly to achieve the desired level of bubbles B If there are too many bubbles and the Collection Cup is overflowing rapidly slowly close the Air Control Valve to achieve desired bubble flow 6 To further adjust and fine tune the Protein Skimmer loosen the Height Adjuster 26 located at the base of the Collect...

Страница 10: ...d reconnect it to the system To ensure optimum filter performance routine maintenance should be performed monthly or less depending on size of tank amount of fish and number of daily feeding If the filter and media are neglected the filter media will become clogged and unable to collect waste material This can affect aquarium water quality and possibly the health of the tank inhabitants Grimy wast...

Страница 11: ...Cleaning your Power Head Inlet Elbow Impeller Cover Lock Impeller Cover Impeller Blades Impeller Motor Outlet Base Rubber End Cap Ceramic Shaft O ring 11 ...

Страница 12: ... Maintenance section in this instruction booklet WATER LEAKING AT FLEXIBLE HOSING CONNECTIONS 1 Disconnect Flexible Hoses from connectors on the MariSys and Overflow Box and clean connectors thoroughly with an Aqua One Double Ended Pipe Brush Reconnect and tighten hose clamps snugly 2 If the Flexible Hosing has slipped from original position remove and clean area then reconnect and tighten hose cl...

Страница 13: ...mer Air Pump with new ones 3 Check air line for kinks 4 Check the Air Control Valve and Check Valve OVERFLOW BOX NOT FUNCTIONING 1 Check power supply and confirm Priming Pump is plugged in 2 No water in Overflow Box add water 3 Check Overflow Box for obstacles 4 Check Hosing and Tubing for kinks or obstructions PRIMING PUMP NOT RUNNING 1 Check power supply and confirm Priming Pump is plugged in 2 ...

Страница 14: ...ed in Australia by Aqua One Distributed in Australia by Kong s Aust Pty Limited 48 Williamson Rd Ingleburn 2565 NSW Australia Distributed in New Zealand by Kong s NZ Limited 52 Glenlyon Avenue Greerton Tauranga New Zealand Distributed in Hong Kong by Kong s Aquarium Supplies Co Ltd No 31 3 F Thriving Industrial Centre 26 38 Sha Tsui Road Tsuen Wan Hong Kong Distributed in the UK by Kong s UK Limit...

Страница 15: ...Instruction Version 30 10 06 ...

Отзывы: