background image

This  appliance  is  not  intended  for  use  by 

children  or  infirm  persons  without  supervi-

sion.  Young  children  should  be  supervised 

to  ensure  that  they  do  not  play  with  the 

appliance. 

Warning:  To  guard  against  injury,  basic 

safety  precautions  should  be  observed, 

including the following:

1.  Read  and  follow  all  safety  instructions  before 

using this appliance.

2.  Danger:  To  avoid  possible  electric  shocks, 

special  care  should  be  taken  since  water  is 

employed in the use of aquarium equipment. For 

each  of  the  following  situations  do  not  attempt 

repairs  yourself.  Return  the  appliance  to  an 

authorised service facility for service or discard the 

appliance.

a) If the filter head falls into water, do not reach for 

it,  unplug  it  and  then  retrieve  it.  If  the  electrical 

components of the appliance get wet, unplug the 

appliance immediately (non immersible equipment 

only).

b)  If  the  filter  shows  any  sign  of  abnormal  water 

leakage,  immediately  unplug  it  from  the  power 

source.

 

c)  Carefully  examine  the  filter  after  installation.  It 

should not be plugged in when there is water on 

parts which are not intended to be wet.

d) Do not operate any filter if it has a damaged cord 

or  plug,  or  if  it  is  malfunctioning,  or  dropped  or 

damaged in any manner.

A “drip loop” (See the diagram) should be arranged 

by the user for each cord connecting an aquarium 

component to a receptacle. The drip loop is the part 

of the cord below the level of the receptacle or the 

connector if an extension cord used. It is used to 

prevent water traveling along the cord and coming 

in contact with the receptacle.

If  the  plug  or  receptacle  does  get  wet,  do  not 

unplug the appliance. Disconnect the fuse or circuit 

breaker that supplies the power to the appliance, 

then unplug and examine for presence of water in 

the receptacle.

3.  Close  supervision  is  necessary  when  the 

appliance is used by or near children.

4. Always unplug the filter from the electrical outlet; 

when  not  in  use,  before  putting  on  or  taking  off 

parts, before any type of maintenance, or cleaning.

 Never yank the cord to pull it from the outlet. Grasp 

the plug and unplug to disconnect.

5. Do not use the filter for reasons other than the 

intended use. The use of attachments that are not 

recommended  or  sold  by  the  filter  manufacturer 

may  cause  the  product  to  be  unsafe.  This  is  not 

recommended.

6. Do not install or store the filter where it will be 

exposed  to  weather  or  temperatures  below 

freezing.

7. Make sure any component mounted on a tank is 

securely installed before operating it.

8. Read and observe all the important notices on 

the filter.

9. Ensure input voltage is the same voltage as your 

local power supply. 

10. If an extension cord is necessary, a cord with a 

proper rating should be used. Care should be taken 

to arrange the cord so that it will not be tripped or 

pulled.

11.  A

  G.F.C.I

  (Ground  fault  circuit  interrupter)  & 

surge  protector  is  recommended  for  all  electrical 

appliances.

12.  Ensure  your  hand  is  dry  when  turning  the 

power  switch  on/off  and  when  inserting/removing 

the power cord from the receptacle. 

13.  If  you  are  in  any  doubt  about  the  electrical 

installation  or  safety  of  this  product  you  must 

consult a qualified electrician.

For Guarantee Conditions, please refer to 

the Guarantee form that is enclosed with 

this product.

Drip loop

Important Safeguards

Содержание AQUIS 1000

Страница 1: ...Instruction Manual Canister Filters AQUIS 500 700 1000 1200 ...

Страница 2: ...ith the receptacle If the plug or receptacle does get wet do not unplug the appliance Disconnect the fuse or circuit breaker that supplies the power to the appliance then unplug and examine for presence of water in the receptacle 3 Close supervision is necessary when the appliance is used by or near children 4 Always unplug the filter from the electrical outlet when not in use before putting on or...

Страница 3: ... otherwise known as an Residual circuit current device RCCD must be also fitted in the supply line IF YOU ARE IN ANY DOUBT ABOUT INSTALLING YOUR APPLIANCE YOU SHOULD CONSULT A QUALIFIED ELECTRICIAN Australia New Zealand and Hong Kong In Australia New Zealand and Hong Kong all products are supplied with fitted plugs This plug should NOT be tampered with in any way or removed Removal or tampering wi...

Страница 4: ...malfunction in any way or if the unit is damaged and requires replacement contact the retailer where the product was purchased for inspection Replacement Parts Filter Media Use Aqua One Genuine Spare Parts Only See your local Aqua One Dealer and look for the number listed below for the spare part you require Alternatively you will find these numbers on the silver label located on the product 500 7...

Страница 5: ...5ppi Noodles Bio Balls Wool Sponge Blue 15ppi Sponge Black 35ppi Noodles Bio Balls Sponge Blue 15ppi Bio Balls Aquis 500 Aquis 1000 Aquis 700 Aquis 1200 Media Basket 1 Media Basket 2 Media Basket 1 Media Basket 2 Media Basket 3 Wool Sponge Blue 15ppi Sponge Black 35ppi Noodles Sponge Blue 15ppi Bio Balls Media Basket 1 Media Basket 2 Media Basket 3 ...

Страница 6: ...the canister body Ensure the filter inlet pipe has the black sealing O ring at the top of it and that the baskets sit flat on top of each other The sealing O ring on the top filter basket is attached to the bottom of the head unit Fig 5 8 Ensure the filter grid is then placed back on top of the last filter basket This is very impor tant Fig 6 Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 1 Remove the 2 boxed acce...

Страница 7: ...p filter basket Fig 6 10 Line the filter inlet pipe up with the feeder pipe on the base of the head unit 11 Press down gently the bottom of the head unit should be flush with the canister body Be careful not to jam the power cord in between the canister and the head unit Do not force it together If it feels tight do not apply any pressure to close it simply remove the head unit and filter baskets ...

Страница 8: ...the tap will have the same effect NO TOOLS ARE REQUIRED HAND TIGHT IS ENOUGH 6 Place the canister in the desired position and feed the hose through the cabinet or stand Fig 4 7 Choose the outlet you wish to use and assemble it You will find you have 2 Walking Sticks the shorter one is generally used for the outlet However if you have a shallow aquarium you can use the longer one 8 Outlet option 1 ...

Страница 9: ...ch the Suction Cups j to the Walking Stick f Fig 6 14 Use the second Walking Stick k for the Inlet Simply attach the Strainer l to the longer side of the Walking Stick k Then Attach two Suction Cups m Fig 7 15 You will notice in your accessory boxes an extension for very deep aquariums Attach the extension onto the bottom of the Walking Stick k then the Strainer l onto the bottom of the extension ...

Страница 10: ... Once the filter is running double check the fittings and seals for water tightness Fig 1 Fig 10 Fig 1 Fig 11 Starting Your Filter On Off 1 Temporarily detach the outlet from the tubing Either the Spray Bar or the Duck Bill Fig 2 2 Place your mouth over the end of the outlet and create siphon effect by sucking on the tube Fig 3 3 Once the siphon begins lower the outlet tube into a bucket Fig 4 4 N...

Страница 11: ... be plugged in Fig 5 METHOD 2 1 Carefully remove the priming cap on the top of the head unit by gently pushing the red safety button outward and rotating the priming cap until it comes off Fig 6 2 Fill the pump lid housing to the brim and replace the priming cap Fig 7 3 Make sure that the priming cap locks firmly back into the red safety button Fig 8 4 Now the Canister Filter is ready to be plugge...

Страница 12: ...ceramic noodles Or any other type of biological media which may be in them several times into the bucket This will clear some of the dirt that can build up and clog the media and prevent the good bacteria which aid in breaking down pollutants in your aquarium from being killed by the chlorine in tap water 9 Either replace or rinse the white wool pad using a high pressure hose It should be replaced...

Страница 13: ...ough the hole in the middle of the impeller Clean any debris which may have built up on the shaft off along with any slime build up on the impeller Fig 8 20 Put the impeller back together and ensure that it rotates freely on the shaft Then reassemble the head unit ensure there is no water on the power cord plug the head unit in and turn on Make certain the impeller is spinning Turn it off Reassemb...

Страница 14: ...ligned with the media basket flow through pipe THE FILTER WILL NOT PRIME 1 Check tubing for kinks 2 Make sure both taps are in the on position vertical 3 The aquarium needs to be filled 4 Make sure the intake tube and or intake strainer is not blocked 5 Ensure the hoses are connected to the unit correctly IN to IN and OUT to OUT THE FILTER WILL NOT START 1 As the previous tips 2 Check the impeller...

Страница 15: ...Road Tsuen Wan Hong Kong Distributed in the UK by Kong s UK Limited C O Aqua Pacific UK Ltd PO Box 268 Romsey Hampshire SO51 0WW United Kingdom www aquaone com au Aqua One and Kong s are registered trademarks Operating flow rates are based on a typical set up with the canister filter placed under the aquarium in a cabinet complete with filter media pumping to a total height of 120cm not including ...

Страница 16: ...ranteed for the remainder of the original manufacturer s guarantee period 5 Guarantee does not cover a Cost of freight postage or the cost of insurance b Service costs arising from failure to correctly adjust the controls of the product or to clean the hoses filter media impellers pump heads failure to observe the manufacturer s instructions or inspections that reveal that the equipment is in norm...

Отзывы: