![Aqua Lung SEA LV2 Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/aqua-lung/sea-lv2/sea-lv2_technical-manual_2958564021.webp)
21
SYMPTOM
POSSIBLE CAUSE
TREATMENT
Leakage or free-flow from the
second stage
1. High first stage MP, should be 135 (±20) PSI
/ 9.3 (± 1.4) BAR.
1.
Refer to Table 1: Troubleshooting
Guide.
2.The MP seat (55) is dirty, worn or damaged.
2. Clean or replace MP seat (55).
3. The lever (60) is set too high.
3. Readjust locknut (62).
4. The lever (60) is bent.
4. Replace the lever (60).
5. The crown seating surface on the inlet fitting
(51) is worn or damaged.
5. Replace the inlet fitting (51).
6. The spring (57) is worn or damaged.
6. Replace the spring (57).
7. The poppet (56) is worn or damaged.
7. Replace the poppet (56).
Low purge or labored breathing
(full cylinder)
1. Low first stage MP, should be 135 (±20) PSI /
9.3 (± 1.4) BAR.
1.
Refer to Table 1: Troubleshooting
Guide.
2. The lever (60) is set too low.
2. Readjust locknut (62).
3. The lever (60) is bent.
3. Replace the lever (60).
4. The MP hose (11) is clogged or obstructed.
4. Clean or replace the MP hose (11).
5.
The spring (57) is worn or damaged.
5. Replace the spring (57).
External Air Leak
(Immersion Test)
1.The MP hose (11) is loose or damaged.
1. Re-torque MP hose (11) at second
stage fitting or replace hose.
2. The MP hose o-ring (25) is damaged.
2. Replace the o-ring (25).
Water entering second stage
1. The mouthpiece (49 or 70) is incorrectly fitted
or damaged.
1. Refit or replace mouthpiece (49 or 70).
2. The diaphragm (48) is damaged.
2. Replace the diaphragm (48).
3. The exhaust valve (53 or 68) is damaged
or improperly seated.
3. Re-seat or replace the exhaust valve
(53 or 68).
4.The diaphragm (48) is improperly seated
in the box bottom (54 or 69).
4. Disassemble and properly reassemble
(check for distortion).
5. The box bottom (54 or 69) is damaged.
5. Check exhaust valve seating surface
or replace box bottom (54 or 69).
6. The inlet fitting o-ring (23) is damaged.
6. Disassemble and replace o-ring (23).
TABLE 2: TROUBLESHOOTING GUIDE SECOND STAGE
CAUTION:
Recommended treatments which require disassembly of the SEA must be performed during a complete
overhaul, according to the prescribed procedures for scheduled service. Do not attempt to perform partial service.
NOTE: This is a partial list of problems and recommended treatments. For more information contact your Aqua Lung
Technical Service Department for assistance with problems not described in the
Table 1 & 2: Troubleshooting Guides.
Содержание SEA LV2
Страница 1: ...Tertiary Branding TECHNICAL MANUAL Survival Egress Air SEA MK LV2 Rev 6 17...
Страница 30: ...SEA MK LV2 Technical Manual 30 MAINTENANCE NOTES...
Страница 31: ...31 MAINTENANCE NOTES...