Aqua Lung i300C Скачать руководство пользователя страница 62

Doc. 12-7874-r06  (11/27/17)

62

TECHNICAL DATA

© Aqua Lung International, Inc. (2017)

NO DECO TIME LIMITS

Altitude 

(meters) 

Depth

( FT )

Altitude 

(feet) 

Z+ ALGORITHM >> NDLS (HR:MIN) AT ALTITUDE (IMPERIAL)

3001  4001  5001  6001  7001  8001  9001  10001  11001  12001  13001

to 

to 

to 

to 

to 

to 

to 

to 

to 

to 

to 

to

3000  4000  5000  6000  7000  8000  9000  10000  11000  12000  13000  14000

3:17 

30  

2:30 

2:21 

2:14 

2:08 

2:02 

1:57 

1:52 

1:47 

1:39 

1:34 

1:29

40  

1:49 

1:21 

1:15 

1:11 

1:08 

1:05 

1:02 

1:00 

0:57 

0:55 

0:53 

0:51

50  

1:05 

0:53 

0:51 

0:49 

0:47 

0:44 

0:42 

0:39 

0:37 

0:35 

0:34 

0:33

60  

0:48 

0:37 

0:35 

0:33 

0:32 

0:30 

0:28 

0:26 

0:24 

0:23 

0:22 

0:21

70  

0:35 

0:26 

0:24 

0:23 

0:21 

0:20 

0:19 

0:18 

0:17 

0:16 

0:16 

0:14

80  

0:26 

0:19 

0:18 

0:17 

0:16 

0:15 

0:14 

0:13 

0:12 

0:11 

0:11 

0:10

90  

0:19 

0:15 

0:14 

0:13 

0:12 

0:11 

0:10 

0:10 

0:09 

0:09 

0:08 

0:08

100 

0:16 

0:11 

0:10 

0:10 

0:09 

0:09 

0:08 

0:08 

0:07 

0:07 

0:07 

0:07

110 

0:12 

0:09 

0:08 

0:08 

0:08 

0:07 

0:07 

0:07 

0:06 

0:06 

0:06 

0:05

120 

0:10 

0:08 

0:07 

0:07 

0:07 

0:06 

0:06 

0:06 

0:05 

0:05 

0:05 

0:05

130 

0:08 

0:07 

0:06 

0:06 

0:06 

0:05 

0:05 

0:05 

0:05 

0:05 

0:04 

0:04

140 

0:07 

0:06 

0:05 

0:05 

0:05 

0:05 

0:05 

0:04 

0:04 

0:04 

0:04 

0:04

150 

0:06 

0:05 

0:05 

0:05 

0:05 

0:04 

0:04 

0:04 

0:04 

0:04 

0:04 

0:03

160 

0:06 

0:05 

0:05 

0:04 

0:04 

0:04 

0:04 

0:04 

0:04 

0:03 

0:03 

0:03

170 

0:05 

0:04 

0:04 

0:04 

0:04 

0:04 

0:03 

0:03 

0:03 

0:03 

0:03 

0:03

180 

0:05 

0:04 

0:04 

0:04 

0:03 

0:03 

0:03 

0:03 

0:03 

0:03 

0:03 

0:03

190 

0:04 

0:04 

0:04 

0:03 

0:03 

0:03 

0:03 

0:03 

0:03 

0:03 

0:03 

0:00

Z+ ALGORITHM >> NDLS (HR:MIN) AT ALTITUDE (METRIC)

916 

1221  1526  1831  2136  2441  2746  3051  3356  3661  3966

to 

to 

to 

to 

to 

to 

to 

to 

to 

to 

to 

to

915 

1220  1525  1830  2135  2440  2745  3050  3355  3660  3965  4270

Depth

( M )

3:37 

2:41 

2:31 

2:23 

2:16 

2:10 

2:04 

1:59 

1:54 

1:50 

1:43 

1:37

12  

1:55 

1:27 

1:21 

1:15 

1:12 

1:08 

1:05 

1:03 

1:00 

0:58 

0:55 

0:54

15  

1:08 

0:55 

0:53 

0:51 

0:49 

0:47 

0:44 

0:42 

0:39 

0:37 

0:36 

0:34

18  

0:50 

0:39 

0:37 

0:35 

0:33 

0:32 

0:30 

0:28 

0:26 

0:24 

0:23 

0:22

21  

0:36 

0:28 

0:26 

0:24 

0:23 

0:21 

0:20 

0:19 

0:18 

0:17 

0:16 

0:16

24  

0:27 

0:20 

0:19 

0:18 

0:17 

0:16 

0:15 

0:14 

0:13 

0:12 

0:11 

0:11

27  

0:20 

0:16 

0:15 

0:13 

0:12 

0:11 

0:11 

0:10 

0:09 

0:09 

0:09 

0:08

30  

0:16 

0:12 

0:11 

0:10 

0:09 

0:09 

0:09 

0:08 

0:08 

0:07 

0:07 

0:07

33  

0:13 

0:09 

0:09 

0:08 

0:08 

0:07 

0:07 

0:07 

0:07 

0:06 

0:06 

0:06

36  

0:10 

0:08 

0:07 

0:07 

0:07 

0:06 

0:06 

0:06 

0:05 

0:05 

0:05 

0:05

39  

0:09 

0:07 

0:06 

0:06 

0:06 

0:06 

0:05 

0:05 

0:05 

0:05 

0:05 

0:04

42  

0:08 

0:06 

0:06 

0:05 

0:05 

0:05 

0:05 

0:05 

0:04 

0:04 

0:04 

0:04

45  

0:06 

0:05 

0:05 

0:05 

0:05 

0:04 

0:04 

0:04 

0:04 

0:04 

0:04 

0:04

48  

0:06 

0:05 

0:05 

0:04 

0:04 

0:04 

0:04 

0:04 

0:04 

0:03 

0:03 

0:03

51  

0:05 

0:04 

0:04 

0:04 

0:04 

0:04 

0:04 

0:03 

0:03 

0:03 

0:03 

0:03

54  

0:05 

0:04 

0:04 

0:04 

0:04 

0:03 

0:03 

0:03 

0:03 

0:03 

0:03 

0:03

57  

0:05 

0:04 

0:04 

0:03 

0:03 

0:03 

0:03 

0:03 

0:03 

0:03 

0:03 

0:03

Altitude 

(meters) 

Depth

( FT )

Altitude 

(feet) 

Z+ ALGORITHM >> NDLS (HR:MIN) AT ALTITUDE (IMPERIAL)

3001  4001  5001  6001  7001  8001  9001  10001  11001  12001  13001

to 

to 

to 

to 

to 

to 

to 

to 

to 

to 

to 

to

3000  4000  5000  6000  7000  8000  9000  10000  11000  12000  13000  14000

3:17 

30  

2:30 

2:21 

2:14 

2:08 

2:02 

1:57 

1:52 

1:47 

1:39 

1:34 

1:29

40  

1:49 

1:21 

1:15 

1:11 

1:08 

1:05 

1:02 

1:00 

0:57 

0:55 

0:53 

0:51

50  

1:05 

0:53 

0:51 

0:49 

0:47 

0:44 

0:42 

0:39 

0:37 

0:35 

0:34 

0:33

60  

0:48 

0:37 

0:35 

0:33 

0:32 

0:30 

0:28 

0:26 

0:24 

0:23 

0:22 

0:21

70  

0:35 

0:26 

0:24 

0:23 

0:21 

0:20 

0:19 

0:18 

0:17 

0:16 

0:16 

0:14

80  

0:26 

0:19 

0:18 

0:17 

0:16 

0:15 

0:14 

0:13 

0:12 

0:11 

0:11 

0:10

90  

0:19 

0:15 

0:14 

0:13 

0:12 

0:11 

0:10 

0:10 

0:09 

0:09 

0:08 

0:08

100 

0:16 

0:11 

0:10 

0:10 

0:09 

0:09 

0:08 

0:08 

0:07 

0:07 

0:07 

0:07

110 

0:12 

0:09 

0:08 

0:08 

0:08 

0:07 

0:07 

0:07 

0:06 

0:06 

0:06 

0:05

120 

0:10 

0:08 

0:07 

0:07 

0:07 

0:06 

0:06 

0:06 

0:05 

0:05 

0:05 

0:05

130 

0:08 

0:07 

0:06 

0:06 

0:06 

0:05 

0:05 

0:05 

0:05 

0:05 

0:04 

0:04

140 

0:07 

0:06 

0:05 

0:05 

0:05 

0:05 

0:05 

0:04 

0:04 

0:04 

0:04 

0:04

150 

0:06 

0:05 

0:05 

0:05 

0:05 

0:04 

0:04 

0:04 

0:04 

0:04 

0:04 

0:03

160 

0:06 

0:05 

0:05 

0:04 

0:04 

0:04 

0:04 

0:04 

0:04 

0:03 

0:03 

0:03

170 

0:05 

0:04 

0:04 

0:04 

0:04 

0:04 

0:03 

0:03 

0:03 

0:03 

0:03 

0:03

180 

0:05 

0:04 

0:04 

0:04 

0:03 

0:03 

0:03 

0:03 

0:03 

0:03 

0:03 

0:03

190 

0:04 

0:04 

0:04 

0:03 

0:03 

0:03 

0:03 

0:03 

0:03 

0:03 

0:03 

0:00

Z+ ALGORITHM >> NDLS (HR:MIN) AT ALTITUDE (METRIC)

916 

1221  1526  1831  2136  2441  2746  3051  3356  3661  3966

to 

to 

to 

to 

to 

to 

to 

to 

to 

to 

to 

to

915 

1220  1525  1830  2135  2440  2745  3050  3355  3660  3965  4270

Depth

( M )

3:37 

2:41 

2:31 

2:23 

2:16 

2:10 

2:04 

1:59 

1:54 

1:50 

1:43 

1:37

12  

1:55 

1:27 

1:21 

1:15 

1:12 

1:08 

1:05 

1:03 

1:00 

0:58 

0:55 

0:54

15  

1:08 

0:55 

0:53 

0:51 

0:49 

0:47 

0:44 

0:42 

0:39 

0:37 

0:36 

0:34

18  

0:50 

0:39 

0:37 

0:35 

0:33 

0:32 

0:30 

0:28 

0:26 

0:24 

0:23 

0:22

21  

0:36 

0:28 

0:26 

0:24 

0:23 

0:21 

0:20 

0:19 

0:18 

0:17 

0:16 

0:16

24  

0:27 

0:20 

0:19 

0:18 

0:17 

0:16 

0:15 

0:14 

0:13 

0:12 

0:11 

0:11

27  

0:20 

0:16 

0:15 

0:13 

0:12 

0:11 

0:11 

0:10 

0:09 

0:09 

0:09 

0:08

30  

0:16 

0:12 

0:11 

0:10 

0:09 

0:09 

0:09 

0:08 

0:08 

0:07 

0:07 

0:07

33  

0:13 

0:09 

0:09 

0:08 

0:08 

0:07 

0:07 

0:07 

0:07 

0:06 

0:06 

0:06

36  

0:10 

0:08 

0:07 

0:07 

0:07 

0:06 

0:06 

0:06 

0:05 

0:05 

0:05 

0:05

39  

0:09 

0:07 

0:06 

0:06 

0:06 

0:06 

0:05 

0:05 

0:05 

0:05 

0:05 

0:04

42  

0:08 

0:06 

0:06 

0:05 

0:05 

0:05 

0:05 

0:05 

0:04 

0:04 

0:04 

0:04

45  

0:06 

0:05 

0:05 

0:05 

0:05 

0:04 

0:04 

0:04 

0:04 

0:04 

0:04 

0:04

48  

0:06 

0:05 

0:05 

0:04 

0:04 

0:04 

0:04 

0:04 

0:04 

0:03 

0:03 

0:03

51  

0:05 

0:04 

0:04 

0:04 

0:04 

0:04 

0:04 

0:03 

0:03 

0:03 

0:03 

0:03

54  

0:05 

0:04 

0:04 

0:04 

0:04 

0:03 

0:03 

0:03 

0:03 

0:03 

0:03 

0:03

57  

0:05 

0:04 

0:04 

0:03 

0:03 

0:03 

0:03 

0:03 

0:03 

0:03 

0:03 

0:03

Содержание i300C

Страница 1: ...Aqua Lung International Inc 2017 Dive Computer Owner s Manual Doc 12 7874 r06 11 27 17 i300C...

Страница 2: ...using a mathematical model This model is merely a way to apply a limited set of data to a large range of experiences The i300C dive computer model is based upon the latest research and experiments in...

Страница 3: ...e person using it with data not the knowledge to use it Remember also that the dive computer does not actually measure and test the composition of your body tissue and blood Using an Aqua Lung dive co...

Страница 4: ...tor 26 7 bLUETOOtH Bluetooth Communication 27 8 LIGHt BACKLIGHT DURATION 27 9 SR SAMPLE RATE 28 SET TIME 28 SET MODE 29 HISTORY 29 SN SERIAL NUMBER 30 DIVE OPERATION 31 INITIATING A DIVE 32 NO DECO DI...

Страница 5: ...ALARM 54 FREE EDT ELAPSED DIVE TIME ALARM 55 FREE DEPTH ALARMS 55 HIGH NITROGEN ALARMS 55 FREE EDT ELAPSED DIVE TIME ALARM 56 REFERENCE 56 UPLOADING DOWNLOADING DATA 57 CARE AND CLEANING 58 SERVICE 58...

Страница 6: ...Doc 12 7874 r06 11 27 17 6 Aqua Lung International Inc 2017 GETTING STARTED...

Страница 7: ...that is your preference Disabling the H2O ACT feature is described in the Dive Surface Mode chapter p 16 Upon activation The unit will enter a Diagnostic Mode The i300C checks the display and voltage...

Страница 8: ...sion if DECO icon is displayed 4 Low Battery 5 Descend Ascend or Stop 6 Value is Maximum 7 Oxygen Saturation 8 Bluetooth is On 9 Decompression DECO or No Decompression NO DECO 10 Time To Surface 11 T...

Страница 9: ...e also used to enter settings activate the backlight and acknowledge the audible alarm Throughout this manual they will be referred to as the ADV and SEL buttons Pressing different combinations of the...

Страница 10: ...ep through menus to toggle or change setpoints to activate the backlight ADV SEL ADV to scroll quickly changing setpoints to scroll quickly through menu lead in screens selections ADV SEL SEL to selec...

Страница 11: ...Doc 12 7874 r06 11 27 17 11 Aqua Lung International Inc 2017 DIVE FEATURES...

Страница 12: ...shifts to slower compartments This is a feature of the decompression model that is the basis for multilevel diving one of the most important advantages that Aqua Lung dive computers offer O2 MIN OXYG...

Страница 13: ...the algorithm and used for N2 O2 calculations and displays relating to Plan Mode will be reduced to the values available at the altitude level that is 915 m 3 000 ft higher than the actual altitude a...

Страница 14: ...ion dive in which Depth exceeded 9 m 30 ft for 1 second a beep will sound and a Safety Stop at the depth set will appear on the Dive Main display with a countdown beginning at the SS time set and coun...

Страница 15: ...nt selected Ascent rate exceeds 9 m 30 FPM for 8 seconds or more Entry into Decompression Mode Deco Conditional Violation above a required Deco Stop Depth for less than 5 minutes Delayed Violation abo...

Страница 16: ...Doc 12 7874 r06 11 27 17 16 Aqua Lung International Inc 2017 DIVE SURFACE MODE...

Страница 17: ...e ADV button to scroll quickly through the selections Some screens simply display data While other screens are lead ins to sub menus and settings Press the SEL button to choose menus or op tions from...

Страница 18: ...countdown shall begin counting from 23 50 to 0 00 hr min 10 minutes after surfacing from a dive The SAT Desat counter shall provide calculated time for Tissue Desatuation at sea level taking into con...

Страница 19: ...e log After exceeding 24 dives the most recent dive is stored while the oldest is deleted Dives are numbered from 1 to 24 starting each time a dive is activated in either Dive or Gauge mode After the...

Страница 20: ...x 999 min ADV SEL back to Log Preview to Data 3 lowest temperature recorded elevation of dive location SEA or EL 2 EL7 LOG DATA 1 LOG DATA 2 ADV SEL LOG DATA 3 back to Log Preview to Data 4 or Log Pre...

Страница 21: ...the Set Gas PO2 Alarm 1 2 and 3 screens the the current PO2 Alarm setting and corresponding MOD Maximum Operating Depth are displayed NOTE When FO2 is set for AIR oxygen related data such as PO2 O2 a...

Страница 22: ...Alarm setting FO2 O2 setting PO2 Alarm setting Gas SET AL ALARMS Pressing the SEL button while viewing the Set AL Lead in screen accesses the Set AL Sub Menu Within this menu you can customize the fo...

Страница 23: ...Elapsed Dive Time Alarm This feature allows you to set an alarm to go off at a predetermined amount of dive time ADV SEL SET EDT AL save setting to change setting setpoint 10 180 min or blank if OFF 4...

Страница 24: ...t 5 20 min blank if OFF DTR AL TRIGGERED flashing SET UTIL UTILITIES Pressing the SEL button while viewing the Set UTIL Lead in screen accesses the Set UTIL Sub Menu Within this menu you can customize...

Страница 25: ...remember to manually activate the i300C before any dive ADV SEL SET H2O ACT save setting to toggle setting ON or OFF 3 UNITS IMP MET The Units feature allows you to select whether MET metric or IMP im...

Страница 26: ...il able 3 or 5 min Safety Stop at depths of 3 4 5 or 6 m 10 15 or 20 ft ADV SEL SET SAFETY STOP save setting toggle setting ON or OFF ADV SEL SET STOP TIME save setting toggle setting 3 or 5 min ADV S...

Страница 27: ...the surface with the screen activated Bluetooth is temporarily deactivated when the i300C enters Sleep Mode screen is turned off or a dive is started The i300C returns to sniffing mode when the i300C...

Страница 28: ...er files for each dive Depending on the chosen set tings and dive durations it is possible to see dives stored in the i300C s onboard Log that have already been overwritten in the PC Download Partitio...

Страница 29: ...rom any Gauge or Viola tion Dive Otherwise you may switch modes freely while in any Surface Mode ADV SEL SET MODE LEAD IN next item in Main Menu access Set Mode ADV SEL SET MODE advance setpoint save...

Страница 30: ...Inc 2017 SN SERIAL NUMBER Information displayed on the Serial Number screen should be recorded and kept with your sales receipt it will be required in the event that your i300C requires factory servi...

Страница 31: ...Doc 12 7874 r06 11 27 17 31 Aqua Lung International Inc 2017 DIVE OPERATION...

Страница 32: ...ve an audible alarm may sound and the priority of infor mation displayed may change This is to indicate a safety recommendation warning or alarm The following infor mation in this chapter demonstrates...

Страница 33: ...ning to nitrox it is bypassed if the i300C is set for air O2 saturation 0 100 current PO2 value FO2 setting DEEP STOP PREVIEW If Deep Stop was set to ON in the UTIL Menu the Deep Stop preview screen i...

Страница 34: ...y in its place during the alarms DEEP STOP MAIN If triggered the Deep Stop will activate upon ascending to within 3m 10 ft below the calculated Deep Stop depth The stop time will be displayed and coun...

Страница 35: ...ve Features chapter for further details NOTE The i300C does not penalize for a missed Safety Stop remaining stop time min sec stop depth SURFACING Upon ascending to 0 9 m 3 ft the i300C transitions to...

Страница 36: ...urface These situations exceed tested limits and can result in loss of some functions for 24 hours after the dive in which a violation occurred OVERVIEW All dives begin with GAS 1 The GAS defaults to...

Страница 37: ...ependent on Depth with slightly less credit given the deeper you are be low the Stop Depth indicated You should stay slightly deeper than the required Stop Depth indicated until the next shallower Sto...

Страница 38: ...ll sound and the alarm LED will flash The full N2 Bar Graph Down Arrow icon and DOWN message will flash until the audible alarm is silenced then the N2 Bar Graph will be solid The Down Arrow icon cont...

Страница 39: ...DV1 status is ignored the i300C will enter DV1 Surface mode for 5 minutes upon surfacing from the dive VIO Violation Down Arrow icon and SURF icon will be flashing After 5 minutes on the surface in D...

Страница 40: ...5 minutes after surfacing from a dive in which a Delayed Violation occurred A full 24 hour continuous surface interval must then be served before all functions are restored During that 24 hours VGM do...

Страница 41: ...alarm is silenced the PO2 will alternate with max depth flashing AFTER AUDIBLE ALARM alternating with PO2 flashing PO2 During Deco The PO2 alarm setting does not apply when in Deco If PO2 reaches 1 6...

Страница 42: ...he screen The Stop Depth and Stop Time moves to the lower portion of the screen When the audible alarm is silenced the message MAX O2 SAT 100 O2 SAT will flash in place of max depth and TTS until on t...

Страница 43: ...it is 100 then it will be replaced with VGM if Violation or SURF time If you surface due to 100 O2 SAT without completing the Deco obligation the full N2 Bar Graph and O2 SAT value 100 will flash wit...

Страница 44: ...Doc 12 7874 r06 11 27 17 44 Aqua Lung International Inc 2017 GAUGE MODE...

Страница 45: ...o the Dive Surface Main screen You may hold the ADV button to scroll quickly through the selections Some screens simply display data While other screens are lead ins to sub menus and settings Press th...

Страница 46: ...5 ft for at least 5 seconds Below is a diagram to help you navigate Gauge Dive Mode functions ALT 1 only if timer is on the main screen ALT 2 back to Main ADV SEL ADV GAUGE DIVE MAIN GAUGE DIVE MAIN...

Страница 47: ...ow ing then min only to 999 with min icon showing ADV SEL start stop Timer add remove Timer from Dive Main screen DV 3 DELAYED VIOLATION 3 If you descend deeper than the maximum functional depth the a...

Страница 48: ...Doc 12 7874 r06 11 27 17 48 Aqua Lung International Inc 2017 FREE MODE...

Страница 49: ...ssociated with the high pressures that competitive type free diving can expose a diver to WARNINGS Ensure that you know which Operating Mode is selected DIVE GAUGE or FREE prior to commencing any dive...

Страница 50: ...button When you reach the end of the menu the i300C will return to the Free Surface Main screen You may hold the ADV button to scroll quickly through the selections Some screens simply display data W...

Страница 51: ...when a dive is started and becomes available as an ALT display When a set Countdown Time reaches 0 00 the audible alarm will sound During which time the graphic CDT will be flashed on the Surface or D...

Страница 52: ...on while viewing the Set AL Lead in screen accesses the Set Free AL sub menu Within this menu you can customize the following two alarm settings ADV SEL SET FREE AL LEAD IN Next item in Main Menu acce...

Страница 53: ...OTE DA 2 and DA 3 are set the same way as DA 1 Press select to save settings and to return to the Main menu from Set DA 3 screen SET MODE Set Mode operates the same way as previously described for Div...

Страница 54: ...temperature Pressing the SEL button will start ON and stop OFF the CDT Countdown Timer min sec temperature ALT 2 This screen displays the current time of day and the maximum dive depth reached during...

Страница 55: ...which time the N2 Bar Graph segments will flash on the Free Dive Main screen In the event that nitrogen continues to increase and reaches the Deco level the VIO violation Alarm will sound During which...

Страница 56: ...Doc 12 7874 r06 11 27 17 56 Aqua Lung International Inc 2017 REFERENCE...

Страница 57: ...300C button controls Information available for retrieval download from the i300C to the PC Download portion of the program includes items such as dive number surface interval time depth dive time star...

Страница 58: ...number serial number s and a copy of your original sales receipt and Warranty Registration Send freight prepaid and insured using a traceable method Non warranty service must be prepaid COD is not acc...

Страница 59: ...on Closely check all of the sealing surfaces for any signs of damage that might impair proper sealing Inspect the button lens and housing to ensure they are not cracked or damaged WARNING If damage or...

Страница 60: ...ow battery condi tion is indicated return the unit to an authorized Aqua Lung dealer for a complete evaluation before attempting to use it RETURNING THE MODULE TO A BOOT If the boot was fitted with a...

Страница 61: ...Doc 12 7874 r06 11 27 17 61 Aqua Lung International Inc 2017 TECHNICAL DATA...

Страница 62: ...05 0 05 0 04 0 04 0 04 0 04 0 04 0 04 0 04 48 0 06 0 05 0 05 0 04 0 04 0 04 0 04 0 04 0 04 0 03 0 03 0 03 51 0 05 0 04 0 04 0 04 0 04 0 04 0 04 0 03 0 03 0 03 0 03 0 03 54 0 05 0 04 0 04 0 04 0 04 0 0...

Страница 63: ...o 7 000 EL4 2 136 to 2 745 7 001 to 9 000 EL5 2 746 to 3 355 9 001 to 11 000 EL6 3 356 to 3 965 11 001 to 13 000 EL7 3 965 13 000 OXYGEN EXPOSURE LIMITS from NOAA Diving Manual PO2 ATA MAX DURATION SI...

Страница 64: ...rs 14 000 feet elevation Measures ambient pressure every 30 minutes when inactive upon activation every 15 minutes while activated Does not measure ambient pressure when Wet Compensates for Altitudes...

Страница 65: ...1 minute Time To Surface 0 to 99 min display if 99 min 1 minute No Deco Deep Stop Time 2 00 to 0 00 min 1 second No Deco Safety Stop Time 5 00 to 0 00 min 1 second Deco Stop Time 0 to 999 min 1 minut...

Страница 66: ...FREE Free Dive Mode FT Feet depth GAU GAUG GAUGE Digital Gauge Dive Mode GTR Gas Time Remaining H2O Water HIST History IMP Imperial measure LAST Previous dive LO Low battery M Meters depth MET Metric...

Страница 67: ...www aqualung com...

Отзывы: