Doc. 12-7874-r06 (11/27/17)
43
DIVE OPERATION
© Aqua Lung International, Inc. (2017)
Alarm On Surface
Upon surfacing, the Dive Main screen is displayed for 10 minutes with access to the Dive ALTs al-
lowed.
• If O2 SAT is 100%, the value will alternate with SURF time on the Main Screen until it is < 100%,
then it will be replaced with VGM (if Violation) or SURF time.
• If you surface due to 100% O2 SAT without completing the Deco obligation, the full N2 Bar Graph
and O2 SAT value (100) will flash with O2 SAT icons for the first 10 minutes, then operation will
enter VGM (Violation Gauge Mode).
• Access to Dive ALT screens is allowed during the first 10 minutes, then access to the Dive Surface
Menu is allowed.
SURFACE < 10 MIN,
100% O2 SAT
SURFACE > 10 MIN,
VGM TRIGGERED
% O2 SAT
flashing
Содержание i300C
Страница 1: ...Aqua Lung International Inc 2017 Dive Computer Owner s Manual Doc 12 7874 r06 11 27 17 i300C...
Страница 6: ...Doc 12 7874 r06 11 27 17 6 Aqua Lung International Inc 2017 GETTING STARTED...
Страница 11: ...Doc 12 7874 r06 11 27 17 11 Aqua Lung International Inc 2017 DIVE FEATURES...
Страница 16: ...Doc 12 7874 r06 11 27 17 16 Aqua Lung International Inc 2017 DIVE SURFACE MODE...
Страница 31: ...Doc 12 7874 r06 11 27 17 31 Aqua Lung International Inc 2017 DIVE OPERATION...
Страница 44: ...Doc 12 7874 r06 11 27 17 44 Aqua Lung International Inc 2017 GAUGE MODE...
Страница 48: ...Doc 12 7874 r06 11 27 17 48 Aqua Lung International Inc 2017 FREE MODE...
Страница 56: ...Doc 12 7874 r06 11 27 17 56 Aqua Lung International Inc 2017 REFERENCE...
Страница 61: ...Doc 12 7874 r06 11 27 17 61 Aqua Lung International Inc 2017 TECHNICAL DATA...
Страница 67: ...www aqualung com...