Doc. 12-7874-r06 (11/27/17)
38
DIVE OPERATION
© Aqua Lung International, Inc. (2017)
DECOMPRESSION STOP MAIN
Deco Stop Main will display upon ascending to within 10 ft (3 m) below the Decompression Stop depth. The mes-
sage STOP, the Full Stop icon (both Arrows with Stop Bar) will be displayed solid. While Decompression Stop
Main is displayed, you may access Gas Menu (if gas 2 is set ON) and Alt screens by pressing the ADV button
repeatedly to cycle through them. They are similar to the No Deco Main/Dive ALT 1, Dive ALT 2, and Dive ALT 3
screens.
TTS 0 - 99, then - - if
greater than 99 min
stop depth
stop time
CV (CONDITIONAL VIOLATION)
Upon ascent above the required Deco Stop depth, operation will enter CV during which no off gassing credit will
be given.
The audible alarm will sound and the alarm LED will flash. The full N2 Bar Graph, Down Arrow icon, and DOWN
message will flash until the audible alarm is silenced, then the N2 Bar Graph will be solid.
> The Down Arrow icon continues to flash until descending below required Stop Depth (within stop zone), then full
Stop icon (Stop Bar with both Arrows) will be on solid.
> If you descend deeper than the required Deco Stop before 5 minutes elapse, Deco operation will continue with
no off gassing credit given for time above the Stop. Instead, for each minute above the Stop 1-½ minutes of
penalty time will be added to required Stop Time.
> The added penalty (deco) time will have to be worked off before obtaining off gassing credit.
> Once the penalty time is worked off, and off gassing credit begins, required Deco Stop Depths and Time will de-
crease toward zero. The N2 Bar Graph will recede into the No Deco zone, and operation will revert to No Deco
mode.
down arrow
flashing
N2 Bar Graph
flashing
Содержание i300C
Страница 1: ...Aqua Lung International Inc 2017 Dive Computer Owner s Manual Doc 12 7874 r06 11 27 17 i300C...
Страница 6: ...Doc 12 7874 r06 11 27 17 6 Aqua Lung International Inc 2017 GETTING STARTED...
Страница 11: ...Doc 12 7874 r06 11 27 17 11 Aqua Lung International Inc 2017 DIVE FEATURES...
Страница 16: ...Doc 12 7874 r06 11 27 17 16 Aqua Lung International Inc 2017 DIVE SURFACE MODE...
Страница 31: ...Doc 12 7874 r06 11 27 17 31 Aqua Lung International Inc 2017 DIVE OPERATION...
Страница 44: ...Doc 12 7874 r06 11 27 17 44 Aqua Lung International Inc 2017 GAUGE MODE...
Страница 48: ...Doc 12 7874 r06 11 27 17 48 Aqua Lung International Inc 2017 FREE MODE...
Страница 56: ...Doc 12 7874 r06 11 27 17 56 Aqua Lung International Inc 2017 REFERENCE...
Страница 61: ...Doc 12 7874 r06 11 27 17 61 Aqua Lung International Inc 2017 TECHNICAL DATA...
Страница 67: ...www aqualung com...