background image

Section #: Title

 

 

 12

 

©Aqua-Hot®

 600D and 675D Use and Care Guide

 

Maintenance 

Maintenance Schedule 

Monthly Maintenance 
 

Check the Aqua-

Hot’s antifreeze and water heating 

solution to ensure that it is at the proper level. This can be 
accomplished by visually checking the coolant level in the Aq-
ua-

Hot’s expansion tank; reference figure 5, page 14.

 

 

Please note that the coolant level should be checked 

ONLY when the Aqua-Hot is at maximum operating tempera-
ture. This should be done immediately after the burner cycles 
off. 
 

At maximum operating temperature, the antifreeze 

and water heating  solution should be at the level marked 

“HOT” on the expansion tank.

 

 

Run the interior heating zones until you feel warm air 

blowing out of the heat exchangers. 

 

Run the burner once a month. This will ensure proper 

operation of the burner. 

Replenishing the Antifreeze and Water Heating Solution 
 

If the antifreeze and water heating solution needs 

replenishing, remove the cap for the expansion bottle and fill 

it to the “HOT” mark. Replace the expansion bottle cap when 

this is complete. 
 

Reference appendices A through C in order to deter-

mine the correct ratio of antifreeze to water, the proper type of 
antifreeze, and the water quality recommendations for the 
Aqua-Hot antifreeze and water heating solution. Reference 
appendix D for the proper tool and instructions for usage in 

measuring the system’s antifreeze mixture ratio.

 

Annual Maintenance 

 

To keep the diesel burner running smoothly, a tune-

up, or annual service should be performed on the unit. An an-
nual service consists of a new fuel nozzle and fuel filter. To 
ensure best diesel-burner performance, always use the rec-
ommended fuel nozzle and fuel filter when replacing these 
parts. 

When the Aqua-Hot is at maximum operating temperature, 
the coolant will be very hot. If the Aqua-

Hot’s heating sys-

tem is accessed, scalding by hot vapor or coolant could 
result. Before cleaning or servicing, disconnect all power 
supplies 

DO NOT operate the burner and/or the electric heating ele-
ment without the antifreeze and water heating solution in 
the Aqua-

Hot’s boiler tank. Doing so will cause serious dam-

age to the heater. 

Propylene glycol that is “Generally Recognized As Safe” by 

the FDA must be utilized for the antifreeze and water heating 
solution. 

NOTE: For additional information regarding this propylene-

glycol based, boiler type antifreeze that has been “Generally 
Recognized As Safe” by the FDA, please reference Appendix 

A, contact Aqua-Hot Heating Systems Technical Support 
Department at +1 (800) 685-4298, or visit our website at 
www.aquahot.com. 

Содержание 675-D

Страница 1: ...USE AND CARE GUIDE 600SERIES 600D and 675D with...

Страница 2: ......

Страница 3: ...nit This guide should be maintained in legible condi tion and kept in a safe accessible location for future review Should you have any suggestions how we can better serve you please do not hesitate to...

Страница 4: ...uch more like home Comfort Zone 4 Low Emissions Aqua Hot s new low emission systems are fumeless and odorless It s good for you good for your neighbor and good for the environment Comfort Zone 5 Over...

Страница 5: ...Measuring Anti Freeze using a Refractometer 17 Owner s Service Log 18 19 Warranty Limited Warranty Statement 20 Caution Notes As you read this information take particular note of the NO TICE CAUTION...

Страница 6: ...material Use caution when working on or near the propane gas system DO NOT connect the 12V DC power to the Aqua Hot if the RV or home requires welding At maximum operating temperatures the coolant wi...

Страница 7: ...AC Wiring Ports 6 Domestic Water Connections 7 Domestic Water Access Panel 8 Diesel Burner 9 Drain Valve 10 Diesel Fuel Inlet Outlet Ports 11 Engine Preheat Inlet Outlet Ports 12 Air Relief Valve 13...

Страница 8: ...e Aqua Hot to heat from one of or a combination of the following heat sources 1 AC Electric Elements When plugged into shore power or operating on a generator the AC Electric Elements may be utilized...

Страница 9: ...o the LOW position will energize one of the two AC elements inside of the Aqua Hot On the LOW setting allow 1 2 hours for the Aqua Hot to reach operating temperature High Switch Moving the High Low sw...

Страница 10: ...ted as needed to maintain the set interior temperature Keep in mind that in some conditions the BURNER and ELECTRIC switches must both be in the ON posi tion to provide enough heat to maintain interio...

Страница 11: ...is opened The heated antifreeze and water solution flows through the hydronic heating system transfer ring heat to the heat ex changer which is then transferred to the sur rounding zone The cooled ant...

Страница 12: ...minate and the diesel burner is not functioning locate the Reporter and check the following 1 Check the Reporter s fault screen for any faults associat ed with this unit 2 Check for loose wire connect...

Страница 13: ...home screen and any tests which are underway at that time will be ended Pumps and Zone Fans Pumps and Zone fans are activated individually and remain active until the Reporter times out or the test is...

Страница 14: ...e and the water quality recommendations for the Aqua Hot antifreeze and water heating solution Reference appendix D for the proper tool and instructions for usage in measuring the system s antifreeze...

Страница 15: ...winterize the Aqua Hot system completely fill the fresh water storage tank Open and close the interior and exterior faucets one at a time until only clear water is pre sent Disinfecting the Domestic W...

Страница 16: ...vel at the expansion tank If the level is low ref erence the maintenance section of this guide for refilling instructions If the Aqua Hot s failure to operate is not resolved with the aforementioned c...

Страница 17: ...in high levels of chemical rust inhibitors Due to their potentially hazardous properties they should never be used in an Aqua Hot heating system Appendix B Antifreeze Mixture Water Quality Recommendat...

Страница 18: ...quid to a gas Rust and Anti Corrosive Inhibitors Another major function of the antifreeze solution is to protect the internal metal components of the Aqua Hot system from corrosion and rust Antifreeze...

Страница 19: ...r Once that is complete peer through the eyeglass of the refractometer to continue to the next step Adjust the Boundary Line Once the glycol solution has been properly applied adjust the calibration s...

Страница 20: ...Section Title 18 Aqua Hot 600D and 675D Use and Care Guide Service Log DATE SERVICE PERFORMED SERVICE CENTER...

Страница 21: ...p 19 Aqua Hot 600D and 675D Use and Care Guide DATE SERVICE PERFORMED SERVICE CENTER Service Log...

Страница 22: ...protect the heater s end user from such de fects which would occur in the manufacturing of the product Thus problems due to improper specifications improper installations improper use the use of acce...

Страница 23: ......

Страница 24: ...eating Systems Inc 7501 Miller Drive Frederick CO 80504 Visit us on line at www aquahot com Call us at 800 685 4298 or 303 651 5500 2018 Aqua Hot Heating Systems Inc Printed In U S A LTE 907 900 Rev C...

Отзывы: