600D and 675D Use and Care Guide
Troubleshooting Guide
The Aqua-Hot Reporter
General Information:
The Aqua-Hot 600 series now contain Aqua-
Hot’s new
Reporter unit. The Reporter serves to replace the electronic
controller in 600-D04, and 675-D04 units and later. Should
the Aqua-Hot cease to operate, complete the following steps.
Verify that the Aqua-
Hot’s access cover is securely in-
stalled. Reference page 5, part number 18. The Aqua-Hot
will not operate if the access cover is not correctly in-
stalled.
Ensure that the vehicle’s fuel tank contains a sufficient
level of fuel. The Aqua-Hot system will not operate if the
fuel level is at, or below 1/4 tank.
Ensure that the Aqua-Hot boiler tank has a sufficient sup-
ply of antifreeze and water heating solution by checking
the level at the expansion tank. If this level is low, refer-
ence the Care & Maintenance section of this guide for
refilling instructions.
Check the Aqua-Hot Reporter faults screen. If faults are
present, record them on a notepad.
If the unit is not made functional by the aforemen-
tioned checks, please contact the Aqua-Hot Heating Systems
Technical Support Department at +1 (800) 685-4298, or visit
our website at www.aquahot.com.
If the Aqua-Hot diesel burner switch indicator light
does not illuminate and the diesel burner is not functioning,
locate the Reporter and check the following:
1.
Check the Reporter’s fault screen for any faults associat-
ed with this unit.
2. Check for loose wire connections on the Reporter by re-
moving the four bolts or screws securing the housing to its
mounting position. It may be necessary to check with your
coach manufacturer to determine the best way to remove
the Reporter.
3. Remove the Reporter and ensure that all connections are
secured, and that the wires are in good condition.
4.
Ensure that the vehicle’s fuel tank has a sufficient level of
fuel.
5. If at this stage the Aqua-Hot does not begin to function,
please contact the Aqua-Hot Heating Systems Technical
Support Department at +1 (800) 685-4298, or visit our
website at www.aquahot.com
The Aqua-Hot Reporter contains both a fault page,
and a fault log. The fault page contains information on faults
that have occurred since the last time the Reporter was reset
or power cycled. The fault log cannot be cleared, and can con-
tain up to four historic fault conditions that may or may not be
related to a presently experienced issue.
Fault Conditions
The Reporter will display the following fault condi-
tions, accompanied by the component which caused the fault
(pump, fan, burner, etc.)
Over-Current
An over-current fault condition occurs when too much
current is drawn by a specific component channel. This fault is
typically, but not always, associated with a pump, or the diesel
burner.