background image

p. 

 

 

©Aqua-Hot®

 600D and 675D Use and Care Guide

 

Aqua-Hot System Features 

Aqua-Hot 600D and 675D Features 

 

The Aqua-Hot Heating System is a low-emissions Hy-

dronic Heating System (heating with hot water) that signifi-
cantly improves your level of comfort, decreases harmful emis-
sions released into the atmosphere, and adds thousands of 
dollars in value to your coach. 

The Aqua-Hot Heating System is four systems in one: 

1.  Interior Heating System 

 

The Aqua-Hot provides quiet, comfortable interior 

 

heat with independent temperature zones that en-

 

sures even temperatures when requested, and where 

 

requested throughout the cabin. 

2.  Bay Heating System 

 

Keep pipes and tanks from freezing in the bay stor-

 

age area. 

3.  Tankless Hot Water System 

 

The tankless design of the Aqua-Hot ensures that 

 

continuous hot water will be supplied whenever it is 

 

requested 

4.  Engine Preheating System 

 

Reduces engine wear due to cold starting by pre-

 

heating the engine from 30°F to 90°F in one hour 

 The Aqua-

Hot System is powered by TribridHot™ technology

 

 

TribridHot™ technology allows the Aqua

-Hot to heat 

from one of, or a combination of the following heat sources. 

1.  AC Electric Elements 

 

When plugged into shore power, or operating on a 

 

generator, the AC Electric Elements may be utilized to  

 

provide heat for light duty heating and hot water 

 

needs. 

2.  Diesel Burner 

 

The diesel burner serves as the primary and most 

 

powerful heating source for the Aqua-Hot, and will 

 

provide adequate heat for all ranges of heating and 

 

hot water needs. 

3.  Vehicle Engine 

 

When driving or idling your coach, the engine’s sur

-

 

plus heat is transferred to the Aqua-Hot, providing  in-

 

terior heat and limited hot water without burning addi-

 

tional fuel. 

NOTE: 

This Aqua

-

Hot product utilizes a propylene glycol 

based antifreeze and water heating solution. This propylene 
glycol based solution is a boiler type antifreeze that is 

Generally Recognized As Safe

” 

(GRAS) by the FDA. For addi-

tional information regarding this 

GRAS

” 

antifreeze product, 

see the Care & Maintenance section of this guide, or contact 
the Aqua

-

Hot Heating Systems Technical Support department 

at +1 (800) 685

-

4298 or visit our website at 

www.aquahot.com.

 

NOTE: The product label is 
attached to the side of the 
Aqua-Hot and provides a 
ready reference to specifi-
cations, test standards 
and important safety no-
tices. 

Содержание 675-D

Страница 1: ...USE AND CARE GUIDE 600SERIES 600D and 675D with...

Страница 2: ......

Страница 3: ...nit This guide should be maintained in legible condi tion and kept in a safe accessible location for future review Should you have any suggestions how we can better serve you please do not hesitate to...

Страница 4: ...uch more like home Comfort Zone 4 Low Emissions Aqua Hot s new low emission systems are fumeless and odorless It s good for you good for your neighbor and good for the environment Comfort Zone 5 Over...

Страница 5: ...Measuring Anti Freeze using a Refractometer 17 Owner s Service Log 18 19 Warranty Limited Warranty Statement 20 Caution Notes As you read this information take particular note of the NO TICE CAUTION...

Страница 6: ...material Use caution when working on or near the propane gas system DO NOT connect the 12V DC power to the Aqua Hot if the RV or home requires welding At maximum operating temperatures the coolant wi...

Страница 7: ...AC Wiring Ports 6 Domestic Water Connections 7 Domestic Water Access Panel 8 Diesel Burner 9 Drain Valve 10 Diesel Fuel Inlet Outlet Ports 11 Engine Preheat Inlet Outlet Ports 12 Air Relief Valve 13...

Страница 8: ...e Aqua Hot to heat from one of or a combination of the following heat sources 1 AC Electric Elements When plugged into shore power or operating on a generator the AC Electric Elements may be utilized...

Страница 9: ...o the LOW position will energize one of the two AC elements inside of the Aqua Hot On the LOW setting allow 1 2 hours for the Aqua Hot to reach operating temperature High Switch Moving the High Low sw...

Страница 10: ...ted as needed to maintain the set interior temperature Keep in mind that in some conditions the BURNER and ELECTRIC switches must both be in the ON posi tion to provide enough heat to maintain interio...

Страница 11: ...is opened The heated antifreeze and water solution flows through the hydronic heating system transfer ring heat to the heat ex changer which is then transferred to the sur rounding zone The cooled ant...

Страница 12: ...minate and the diesel burner is not functioning locate the Reporter and check the following 1 Check the Reporter s fault screen for any faults associat ed with this unit 2 Check for loose wire connect...

Страница 13: ...home screen and any tests which are underway at that time will be ended Pumps and Zone Fans Pumps and Zone fans are activated individually and remain active until the Reporter times out or the test is...

Страница 14: ...e and the water quality recommendations for the Aqua Hot antifreeze and water heating solution Reference appendix D for the proper tool and instructions for usage in measuring the system s antifreeze...

Страница 15: ...winterize the Aqua Hot system completely fill the fresh water storage tank Open and close the interior and exterior faucets one at a time until only clear water is pre sent Disinfecting the Domestic W...

Страница 16: ...vel at the expansion tank If the level is low ref erence the maintenance section of this guide for refilling instructions If the Aqua Hot s failure to operate is not resolved with the aforementioned c...

Страница 17: ...in high levels of chemical rust inhibitors Due to their potentially hazardous properties they should never be used in an Aqua Hot heating system Appendix B Antifreeze Mixture Water Quality Recommendat...

Страница 18: ...quid to a gas Rust and Anti Corrosive Inhibitors Another major function of the antifreeze solution is to protect the internal metal components of the Aqua Hot system from corrosion and rust Antifreeze...

Страница 19: ...r Once that is complete peer through the eyeglass of the refractometer to continue to the next step Adjust the Boundary Line Once the glycol solution has been properly applied adjust the calibration s...

Страница 20: ...Section Title 18 Aqua Hot 600D and 675D Use and Care Guide Service Log DATE SERVICE PERFORMED SERVICE CENTER...

Страница 21: ...p 19 Aqua Hot 600D and 675D Use and Care Guide DATE SERVICE PERFORMED SERVICE CENTER Service Log...

Страница 22: ...protect the heater s end user from such de fects which would occur in the manufacturing of the product Thus problems due to improper specifications improper installations improper use the use of acce...

Страница 23: ......

Страница 24: ...eating Systems Inc 7501 Miller Drive Frederick CO 80504 Visit us on line at www aquahot com Call us at 800 685 4298 or 303 651 5500 2018 Aqua Hot Heating Systems Inc Printed In U S A LTE 907 900 Rev C...

Отзывы: