AQUA FORTE ECONOBEAD EB-50 Скачать руководство пользователя страница 3

MAINTENANCE ECONOBEAD (EN)

1.  When the pump is running and the multiport is on Filter open the sludge drain (B) 

for 15-20 seconds. This will purge the large solids that have made it into the fi lter and 
settled out in the bottom of the tank to waste. Close the valve. 

2.  Turn of the pump and move the multiport valve to the rinse position. Press the handle 

powerful down and turn it the way it is necessary. Let the handle lose and check if it is 
in the right position. In the rinse position the valve will let some air escape to the sewer 
and some water during the use of the blower. 

3.  Activate the blower unit for 1-2 minutes. During this time the beads and debris are 

dispersed throughout the interior of the fi lter. This breaks up the beads and releases the 
trapped particles. This debris then can easily be backwashed out to waste. The air and 
small dirt will go through the multiport to the sewer

4. 

!!IMPORTANT!!

 Some water has been forced out of the fi lter. The tank needs to be 

entirely full of water before backwash is performed. To fi ll the tank with water, open the air release valve (E) at the top of the fi lter 
and turn on the pump. When water sprays out the air release valve, the tank is full. Turn off  the pump and shut the air release valve.

5.  Move the multiport to the backwash position and turn on the pump. The water will go through the fi lter the other way around (from 

C to A) and transports the loosened dirt through the multiport to the sewer. When the water is clear in the sight glass you know that 
the backwash is done (1 till 2 minutes).

6.  Move the multiport valve to the rinse position and turn on the pump. Now the last dirt that is still in the fi lter will go the normal way 

(from A to C) to the sewer. This you can see in the sight glass till the water is clear (1 till 2 minutes).

Stop the pump and move the multiport valve to the fi lter position and turn on the pump. Backwash is done.

Do this cleaning instruction in the summer 2 till 3 times a week and outside the season once a week. 

*Note*

 The backwash instructions on the label of the blower are a short version of the above instructions.

WATER SAVING DRAIN: 

This EconoBead fi lter has standard a water saving sludge drain. The water saving sludge drain allows a low 

volume backwash if water is in short supply, expensive, or you have a low volume pond, but heavily stocked. After using the Blower 
or an initial hydraulic backwash to break up the bead pack, let the heavy solids settle in the water below the bead pack then open 
the Sludge drain and drain them to waste. The sludge drain will allow the entire tank to be drained, without losing beads through the 
sludge drain. So one is only using the water volume of the fi lter tank to wash the beads. This saves many gallons of water that may be 
used with an hydraulic backwash. 

NOTE:

 The “normal” backwash procedure does cost more water, but by refi lling your pond after backwash you will make, necessary, 

water changes automatically! Water changes of 5 to 10% per week are a good rule of thumb for most ponds. 

3

Содержание ECONOBEAD EB-50

Страница 1: ...t kunt u het spoelproces gemakkelijk volgen Wanneer het water in het kijkglas helder wordt weet u dat het spoelproces is voltooid 1 tot 2 minuten 6 Stop de pomp zet de 6 wegklep op RINSE en start de p...

Страница 2: ...Sichtglas wieder glasklar ist 1 bis 2 Minuten wei man das der Sp lvorgang abgelaufen ist 6 Pumpe abschalten die 6 wegeklappe in RINSE Stand und die Pumpe wieder starten Jetzt wird der letzte Schmutz d...

Страница 3: ...d dirt through the multiport to the sewer When the water is clear in the sight glass you know that the backwash is done 1 till 2 minutes 6 Move the multiport valve to the rinse position and turn on th...

Страница 4: ...le filtre dans le sens inverse de C A pour vacuer les particules d tach es vers l gout travers la vanne 6 voies En montant un hublot du c t WASTE vous pouvez facilement suivre le d roulement de la pha...

Страница 5: ...rdoor de zeef ook met water zal worden overspoeld 2 Het vuil dat tussen de zeefelementen zit verwijderen alleen indien nodig Het vuil dat tussen de zeefelementen zit kunt u het beste met een krachtige...

Страница 6: ...with a powerful spray nozzle or a high pressure machine For this way of cleaning you have to place the sieve in an upright position or take the sieve out of the unit ENTRETIEN ULTRASIEVE MIDI FR Il e...

Страница 7: ...et met een nieuwe behuizing of elektrisch gedeelte meegeleverd Bij eventuele twijfel over de aansluiting een erkende installateur raadplegen WARTUNGAQUAFORTEPOWERUVC DE Bei Wartung Demontage unbedingt...

Страница 8: ...AQUAFORTEPOWERUVC FR Lors de travaux d entretien d montage sur l appareil toujours couper l alimentation de courant L appareil doit tre nettoy 2 fois par an Lorsque la croissance des algues et ou l en...

Страница 9: ...n ist kein Garantie Folgen Sie unter stehender Anleitung zwecks Wartung MAINTENANCE DM VARIO Dependant on water hardness and internal pump temperatures it might be necessary to remove lime scale depos...

Страница 10: ...jn Leg de rotor in een plastic kom bakje gevuld met hetzelfde anti kalk middel en laat beide 24 uur staan Na 24 uur afspoelen met water en pomp weer assembleren Das Pumpengeh use aufrecht stellen und...

Отзывы: