6.1. Installation of the aquasuite software

Installation of the aquasuite software

Installation of the aquasuite software

Installation of the aquasuite software

For configuration and monitoring of our products with USB interface, the aqua-
suite software is available for download from our website www.aqua-computer.de.
You will find the setup program in the support section of the website under Down-
loads/Software.
The setup program checks all connected USB devices for embedded update ser-
vice periods and offers various aquasuite versions depending on detected devices.
If no device with update service for the latest aquasuite version is found, a warning
is displayed and older aquasuite versions that do not require an update  service
purchase can be selected for installation. For installation and update service vali-
dation, an internet connection is required.
The latest aquasuite version may also be installed if no suitable update service pe-
riod has been found in a device. Subsequently, update service may be purchased
or an existing key may be entered within the aquasuite. These functions can be ac-
cessed in the aquasuite/Updates tab.

6.2.

6.2.

6.2.

6.2. Basic operation

Basic operation

Basic operation

Basic operation

The program  window  is divided into two main  areas. On the left side, a list of
“overview pages”, data quick view, data logger, device pages, aquasuite web and
aquasuite configuration is displayed, the right side shows the details of the current-
ly selected list element. The list can be hidden or restored by clicking the arrow
symbol in the upper left corner.
List elements may be minimized or maximized for easier access by clicking the title
bar. The title bars may contain various symbols that will be explained in the follow-
ing chapter.

6.3.

6.3.

6.3.

6.3. Symbols in the headlines

Symbols in the headlines

Symbols in the headlines

Symbols in the headlines

Click the plus symbol in the “Overview pages” headline to create a new
overview page.

Clicking the monitor symbol will toggle desktop mode for this overview
page. While desktop mode is active, the color of the symbol will change
to orange.
Overview page: Clicking the padlock symbol will unlock or lock this over-
view page for editing. Device: Device can not be used due to update ser-
vice problems, see “Updates and update service” for details.
Clicking the gear symbol will access the basic configuration page of the
selected list element.

In  order  to save all settings  into a device, click the  disk  symbol in  the
headline.

- 6 -

Aqua Computer GmbH & Co. KG

© 2019-2020

Gelliehäuser Str. 1, 37130 Gleichen

computer

aqua

Содержание farbwerk nano

Страница 1: ...and installation manual farbwerk nano aquasuite version X 17 Current as of April 2020 All information contained in this manual is subject to change without prior notice All rights reserved 2019 2020 A...

Страница 2: ...nd activating edit mode 7 7 3 Adding new elements 7 7 4 Editing existing elements 8 7 5 Values and names 8 7 6 Detailed data elements 8 7 7 Log data chart 8 7 8 User defined Images text drawing elemen...

Страница 3: ...tion start up 20 15 5 Service administration 20 15 6 Audio and video 20 15 7 Updates and update service 20 16 Technical details and care instructions 21 16 1 Technical details 21 16 2 Care instruction...

Страница 4: ...ernal version product code 53280 One USB cable with female header replacement part no 53215 External version product code 53281 One USB cable with type A connec tor replacement part no 53261 Four blac...

Страница 5: ...fly Toggle strip on off by pressing the button briefly By briefly pressing the button the connected strip can be switched on or off 5 2 5 2 5 2 5 2 Adjust strip brightness by holding the button Adjust...

Страница 6: ...on Basic operation Basic operation Basic operation The program window is divided into two main areas On the left side a list of overview pages data quick view data logger device pages aquasuite web an...

Страница 7: ...lying desktop symbols If a overview page is unlocked for editing while desktop mode is active the page will be displayed in the aquasuite window for editing and the current desktop will be displayed a...

Страница 8: ...ilable Headline only Compact display as a headline Text Displays the numerical value in a box with a headline Bar graph Displays numerical value as well as bar graph Chart Displays the value in chrono...

Страница 9: ...export individual elements select the element or elements perform a right click and select Export selected from the context menu For import right click a free spot of the page and select Import page...

Страница 10: ...n be configured To add data to the chart first select the Data sources tab in the chart configura tion and select a data set to be displayed If no data sources are available you will have to configure...

Страница 11: ...XML file To do so select Analyze data below the Data log headline in the listing Select the Data sources tab in the chart configuration and select a data set to be exported If no data sources are ava...

Страница 12: ...d This service supplies various data from PC components and imported data from aquasuite web additionally sensor data provided by third par ty software can be accessed In order to access third party s...

Страница 13: ...from the su perimposed list of available effects The controller name can be altered from its default as well Confirm you selection by clicking the check symbol in the lower right corner The configura...

Страница 14: ...n LED controllers Multi assign LED controllers Multi assign LED controllers Select the LED controller s to be multi assigned and click the multi assign symbol to create multiple entries for the select...

Страница 15: ...sktop range to evaluate for the effect Prerequisites and limitations The AMBIENTpx effect requires Microsoft Windows operating system version 8 1 or newer Screen content preventing analysis by DRM or...

Страница 16: ...4 12 4 USB power supply USB power supply USB power supply USB power supply The farbwerk nano is supplied with power through the USB connection In default configuration power consumption is limited to...

Страница 17: ...plus symbol in the upper right corner of the Virtual Software Sensors window Each Virtual Software Sensor al ways has an Out element which will provide the resulting sensor value In the settings dial...

Страница 18: ...uasuite does not have to be running for hotkeys to be operational if desk top pages are used the aquasuite must be running Do not use key combinations for this function that are required by other appl...

Страница 19: ...uter forums is provided for your convenience 14 3 14 3 14 3 14 3 Data import Data import Data import Data import To import a data set from the Aqua Computer server the access key of the data set is re...

Страница 20: ...ring features of the background service can be disabled for specific categories if errors occur 15 6 15 6 15 6 15 6 Audio and video Audio and video Audio and video Audio and video The background servi...

Страница 21: ...the selected device and stored on the Aqua Computer update server The key will not have to be re entered after re installation of the software or transfer of the de vice to another computer but transf...

Страница 22: ...d to receive feedback For answers on frequently asked questions please also check our web site www aqua computer de You might also want to visit our forums and discuss our products with experienced mo...

Отзывы: