Fumes and gas exhaust hose reel
12
WARNING!
To reduce risk of severe injury or matrial damages, it
is advised to have two (2) technicians working on the
parameters of limit switches. One (1) technician to operate
the UP/DOWN switches (wall mounted or pendant) and one
(1) to set the limit switches.
Hose reel is factory set for a safe and proper use of hose length contained on hose drum. To
readjust or modify the limit switches, refer to step by step procedure listed below.
1 .
Remove tube motor protective cap covering the UP/DOWN limit switch buttons.
Location to the protective cap is between the side round disk (figure 7) and side support bracket
(figure 8). The use of a long stem flat head screwdriver could be needed.
2.
Both buttons (yellow for maximum DOWN and white for maximum UP hose positions)
underneath the protective cap should be "popped up". This determines the limit switches
were set and locked.
If the hose is completely or partly wrapped around the drum, technicians will begin with setting the
maximum hose DOWN setting.
Figure 8
Figure 7