  8.1  Operational checklist

 1.

  Monitor  the  physical  condition  of  the  collector  and  repair  or  replace  any  damaged 

components. Routine inspections will minimize downtime and maintain optimum system 

performance.  This  is  particularly  important  on  continuous  duty  applications.  With  the 

compressed air supply ON, check the cleaning valves, solenoid valves, and tubing for leaks. 

Replace as necessary.

 2.

  Monitor pressure drop across filters. Abnormal changes in pressure drop indicate a change 

in operating conditions and possibly a fault to be corrected.

 3.

  Monitor exhaust.

 4.

  Monitor dust disposal. 

  8.2  Cellulose Filter

The filters pulsing system is a successful way to clean the filter. Filter life is increased if system is 

pulsed regularly according to usage. Over a period of time, a visual inspection or a decrease in air 

flow may indicate that the filter be removed from the table for manual cleaning.
To manually clean the filter outside the table, follow these steps:
• 

Open covers on the right side of the table and slide out filters.

•  

Remove filter. The filter should then be held at its horizontal position so as to be tapped for 

removal of debris. This procedure may be done directly over a waste bag for easy disposal.

•  

Blow compressed air through the filter in the reverse direction of air flow. This should be 

done at the exterior of the shop (room) or in a well-ventilate area.

•  

Do not wet or clean the cartridge with any liquid, as it may cause the forming of unwanted 

blockage on the filter media. The filter may be weakened causing perforations to the media 

and ultimately damage of the blower.

•  

The filter needs to be replaced periodically. The filter life can range from 6 to 18 months 

depending on many factors ranging from type of application, density, particle size, humidity, 

oil, etc…

  8.3  Dust Drawer

• 

The dust drawer should be emptied periodically. Perform visual inspections during the first 

few weeks of operation to determine proper dumping cycle.

•  

Periodically inspect the gasket to ensure proper sealing. Replace if needed.

Содержание MAXIBENCH MB-1000

Страница 1: ...enance This manual is property of the owner Leave with the unit when set up and start up are complete AQC Dust Collecting Systems inc reserves the right to change design and specifications without pri...

Страница 2: ...verse pulse cleaning optional 6 5 6 Hinged Side Panels optional 6 6 Start up 6 6 1 Check list 6 6 2 Start Stop procedure 7 7 Safety measures 7 7 1 Workers Staff 7 7 2 Electrical components 7 7 3 Explo...

Страница 3: ...asures and maintenance instructions 2 INFORMATION ON THE DOWNDRAFT BENCH Model Serial number Delivery date Date of installation Name of customer Address Accessories Other WARNING MAXIBENCH is not desi...

Страница 4: ...d or explosion properties of combustible materials when determining the location and operation of all dust fume or mist collection equipment 4 PURPOSE AND INTENDED USE WARNING Misuse or modification o...

Страница 5: ...unit The MAXIBENCH is a self contained unit and requires no special installation accommodations 5 3 Electrical connection WARNING The electrical connection must be performed by a certified electricia...

Страница 6: ...mal performance it is recommended that pulsing sequences should be performed 3 times a day on tables in OFF mode Note Neglecting to pulse your filter regularly will reduce filter life 5 6 Hinged Side...

Страница 7: ...the filter section 7 3 Explosive dusts If stored dusts have an explosion or flammable risk once stored in dust storage compartment an explosion relief venting system or a fire extinguishing device is...

Страница 8: ...g To manually clean the filter outside the table follow these steps Open covers on the right side of the table and slide out filters Remove filter The filter should then be held at its horizontal posi...

Страница 9: ...ve the aluminum sparks trap filter 3 Wash or brush away dirt in the filter Ensure you do not damage the mesh fabric 4 Proceed with a visual inspection for tears or rips Replace if necessary Put filter...

Страница 10: ...an be viewed through the back of the motor Access doors open or not closed tight Check that all access doors are in place and secured Filter plugged Check the filter Clean or replace if needed Dust st...

Страница 11: ...arranty customer must notify Seller in writing of the Product defect which notice shall include a reasonable description of the defect within 10 days from the date such defect is discovered or ought t...

Страница 12: ...he possibility of such damages or could have reasonably foreseen them 12 3 Fire and Explosion and Acceptance of Risk Customer acknowledges that improper installation or use of the Product may result i...

Отзывы: