WARNING:

 Check the data plate on this unit before installation. Connect the unit only to the voltage 

and frequency listed on the data plate. Connect only to 1 or 3 phase as listed on the data plate.

!

 

  

 

 

 

!

 

!

CAUTION:

 Do not use ordinary steel wool as any particles left on the surface will rust.

 

WARNING:

 IMPROPER GROUNDING COULD RESULT IN ELECTRICAL SHOCK!

 This 

appliance is equipped with a three prong (grounded) plug for your protection against electrical 
shock hazard and should be plugged directly into a properly grounded three prong receptacle. 
Do not cut or remove the grounding prong from this plug.

!

!

SPECIFICATIONS 

MODEL 

WIDTH  DEPTH  HEIGHT  VOLTAGE  AMPS 

SPTU-30 

23.75” 

19.25” 

4.625” 

120 

4.1 

SPTU-30 

23.75” 

19.25” 

4.625” 

208/240 

2.1 / 2.4 

SPTU-30N 

19.25” 

19.25” 

4.625” 

120 

3.0 

SPTU-30N 

19.25” 

19.25” 

4.625” 

208/240 

1.6 / 1.8 

SPTU-50 

34.75” 

19.25” 

4.625” 

120 

SPTU-50 

34.75” 

19.25” 

4.625” 

208/240 

3.6 / 4.2 

SPTU-50N 

30.25” 

19.25” 

4.625” 

120 

5.8 

SPTU-50N 

30.25” 

19.25” 

4.625” 

208/240 

3.0 / 3.5 

 
 

 

GENERAL INSTALLATION INSTRUCTIONS 

 

This unit has been inspected and tested at the factory prior to shipment. 
 
Unpack the unit and remove all packing materials. Place on a flat horizontal surface at the desired location. 
 

 

NEVER USE

 a wire brush, steel or abrasive scouring pads (except stainless), scraper, file or other steel 

tools. Surfaces which are marred collect dirt more rapidly and become more difficult to clean. Marring also 
increases the possibility of corrosive attack. 
 

NEVER

 use any corrosive cleaner. Use only cleaners approved for stainless steel. 

 

NEVER

 use cleaning solvents with a hydrocarbon base. 

 
 

GENERAL INSTALLATION 

 

1. 

  

Always clean equipment thoroughly before first use. (See general cleaning instructions) 

2.   Check ratings label for your model designation and electrical ratings. 
3.   For best results, use stainless steel countertops. 

 

 

 

Содержание SPTU- 50

Страница 1: ...uids in the vicinity of this or any other appliance Keep the area free and clear of combustibles See ANZI Improper installation operation service or maintenance can cause property damage injury or death Read and understand these instructions thoroughly before positioning installing maintaining or servicing this equipment INSTALLATION AND OPERATING INSTRUCTIONS SPTU UTILITY THERMO DRAWER Model Numb...

Страница 2: ...ation must comply with CSA STANDARD C 22 2 Number 0 M1982 General Requirements Canadian Electrical Code Part II 109 M1981 Commercial Cooking Appliances NOTICE Local codes regarding installation vary greatly from one area to another The National Fire Protection Association Inc states in its NFPA96 latest edition that local codes are Authority Having Jurisdiction when it comes to requirement for ins...

Страница 3: ... Exploded Views 7 Specifications 4 Parts List 9 General Installation Instructions 4 Wiring Schematics 11 Cleaning 5 Notes 12 Troubleshooting Service 5 Warranty 13 Operation 6 LOCATION OF DATA PLATE The data plate for the SPTU is located on the back of the unit IMMEDIATELY INSPECT FOR SHIPPING DAMAGE All containers should be examined for damage before and during unloading The freight carrier has as...

Страница 4: ... 1 6 1 8 SPTU 50 34 75 19 25 4 625 120 7 SPTU 50 34 75 19 25 4 625 208 240 3 6 4 2 SPTU 50N 30 25 19 25 4 625 120 5 8 SPTU 50N 30 25 19 25 4 625 208 240 3 0 3 5 GENERAL INSTALLATION INSTRUCTIONS This unit has been inspected and tested at the factory prior to shipment Unpack the unit and remove all packing materials Place on a flat horizontal surface at the desired location NEVER USE a wire brush s...

Страница 5: ...repeat 4 Dry with a lint free towel or paper towel NOTE THIS APPLIANCE SHALL NOT BE CLEANED WITH A WATER JET GENERAL TROUBLESHOOTING If the unit fails to operate check the following 1 Is the unit connected to a live power source 2 Check the circuit breaker 3 Is the power switch on and pilot light glowing 4 Check the data plate Are you operating the unit on the proper voltage If the above checks ou...

Страница 6: ... the power switch is turned on and the timer is set to zero This mode will keep product above 150ºF after a HEAT cycle has finished HEAT MODE HEAT mode is on when the timer is set to an allotted time After the HEAT Cycle ends and the timer hits zero the unit will automatically enter HOLD mode Some experimentation will be necessary in determining heat times The quantity and type of product in the d...

Страница 7: ...7 EXPLODED VIEW SPTU ...

Страница 8: ...8 EXPLODED VIEW CONTINUED SPTU ...

Страница 9: ...5 25000065 25000145 25000045 WELDMENT DRAWER COVER 1 15 25000169 25000069 25000149 25000049 PAN DRAWER 1 16 8353200 SAME SAME SAME RIVNUT 1 4 20 THIN HEAD 4 17 8507600 SAME SAME SAME WASHER FLAT 1 4 8 18 8641500 SAME SAME SAME BEARING STAINLESS ROLLER SLIDES 4 19 8354000 SAME SAME SAME RIVET POP 1 8 SS 10 20 25000185 25000085 25000195 25000095 INSULATION TOP 1 1 21 25000186 25000086 25000196 25000...

Страница 10: ...AME SAME SCREW MACH 6 32 X 1 4 LG 2 42 8400100 SAME SAME SAME NUT HEX KEPS 6 32 4 43 8839110 SAME SAME SAME LABEL CAUTION HOT SURFACE 2 44 8861000 SAME SAME SAME LABEL SPEC 1 45 8130000 SAME SAME SAME 8 32 X 3 8 TYPE T 7 46 8506000 SAME SAME SAME LOCKWASHER EXT TOOTH 10 1 47 8422400 SAME SAME SAME 10 24 HX NUT GRN 1 48 1196000 SAME SAME SAME CONNECTOR WIRE SETSCREW 11 2 49 8967400 SAME SAME SAME S...

Страница 11: ...11 WIRING SCHEMATIC ...

Страница 12: ...12 NOTES ...

Страница 13: ...he conclusion of this warranty period portable units must be taken to or sent prepaid to the APW Wyott Authorized Service Agency for in warranty repairs No mileage or travel charges are allowed on portable units after the first day of use If the customer wants on site service they may receive same by paying the travel and mileage charges Exceptions to this rule 1 countertop warmers and cookers whi...

Отзывы: