background image

 

 

  

 

 

 

 

!

!

DANGER: 

This symbol warns of imminent hazard which will result in serious injury or 

death.

 

  

 

 

 

 

!

!

CAUTION: 

This symbol refers to a potential hazard or unsafe practice, which may result in 

minor or moderate injury or product or property damage.

 

  

 

 

 

 

!

!

WARNING: 

This symbol refers to a potential hazard or unsafe practice, which could result 

in serious injury or death.

 

  

 

 

 

 

!

!

NOTICE: 

This symbol refers to information that needs special attention or must be fully 

understood even though not dangerous.

!

CAUTION:

 These models are designed, built, and sold for commercial use. If these models are 

positioned so the general public can use the equipment make sure that cautions, warnings, and 
operating instructions are clearly posted near each unit so that anyone using the equipment will 
use it correctly and not injure themselves or harm the equipment.

 

  

 

 

 

!

  

 

 

 

!

 

!

WARNING: 

 - 

SHOCK HAZARD

 Do not open any panels that require the use of tools.

 

WARNING:

 Improper installation, adjustment, alteration, service or maintenance can cause 

property damage, injury or death. Read the Installation, Operating and Maintenance Instructions 
thoroughly before installing or servicing this equipment. 

!

!

!

 

  

 

 

 

!

NOTICE:

 The unit when installed, must be electrically grounded and comply with local codes, or in 

the absence of local codes, with the national electrical code ANSI/NFPA70- latest edition. 
Canadian installation must comply with CSA-STANDARD C.22.2 Number 0 M1982 General 
Requirements-Canadian Electrical Code Part II, 109-M1981- Commercial Cooking Appliances.

!

 

  

 

 

 

!

NOTICE:

 Local codes regarding installation vary greatly from one area to another. The National 

Fire Protection Association, Inc. states in its NFPA96 latest edition that local codes are “Authority 
Having Jurisdiction” when it comes to requirement for installation of equipment. Therefore, 
installation should comply with all local codes. 

APW  Wyott

  takes  pride  in  the  design  and  quality  of  our  products.  When  used  as  intended  and  with 

proper  care  and  maintenance,  you  will  experience  years  of  reliable  operation  from  this  equipment.  To 
ensure  best  results,  it  is  important  that  you  read  and  follow  the  instructions  in  this  manual  carefully. 
Installation  and  start-up  should  be  performed  by  a  qualified  installer  who  thoroughly  read,  understands 
and follows these instructions. 
If you have questions concerning the installation, operation, maintenance or service of this product, write 
Technical Service Department APW/Wyott Foodservice Equipment Company, P.O. Box 1829, Cheyenne, 
WY 82003. 
 

SAFETY PRECAUTIONS 

Before installing and operating this equipment be sure everyone involved in its operation is fully 
trained and is aware of all precautions. Accidents and problems can result by a failure to follow 
fundamental rules and precautions.

 

 

 
The following words and symbols, found in this manual, alert you to hazards to the operator, 
service personnel or the equipment. The words are defined as follows. 

 

 

 

 

Содержание SPTU- 50

Страница 1: ...uids in the vicinity of this or any other appliance Keep the area free and clear of combustibles See ANZI Improper installation operation service or maintenance can cause property damage injury or death Read and understand these instructions thoroughly before positioning installing maintaining or servicing this equipment INSTALLATION AND OPERATING INSTRUCTIONS SPTU UTILITY THERMO DRAWER Model Numb...

Страница 2: ...ation must comply with CSA STANDARD C 22 2 Number 0 M1982 General Requirements Canadian Electrical Code Part II 109 M1981 Commercial Cooking Appliances NOTICE Local codes regarding installation vary greatly from one area to another The National Fire Protection Association Inc states in its NFPA96 latest edition that local codes are Authority Having Jurisdiction when it comes to requirement for ins...

Страница 3: ... Exploded Views 7 Specifications 4 Parts List 9 General Installation Instructions 4 Wiring Schematics 11 Cleaning 5 Notes 12 Troubleshooting Service 5 Warranty 13 Operation 6 LOCATION OF DATA PLATE The data plate for the SPTU is located on the back of the unit IMMEDIATELY INSPECT FOR SHIPPING DAMAGE All containers should be examined for damage before and during unloading The freight carrier has as...

Страница 4: ... 1 6 1 8 SPTU 50 34 75 19 25 4 625 120 7 SPTU 50 34 75 19 25 4 625 208 240 3 6 4 2 SPTU 50N 30 25 19 25 4 625 120 5 8 SPTU 50N 30 25 19 25 4 625 208 240 3 0 3 5 GENERAL INSTALLATION INSTRUCTIONS This unit has been inspected and tested at the factory prior to shipment Unpack the unit and remove all packing materials Place on a flat horizontal surface at the desired location NEVER USE a wire brush s...

Страница 5: ...repeat 4 Dry with a lint free towel or paper towel NOTE THIS APPLIANCE SHALL NOT BE CLEANED WITH A WATER JET GENERAL TROUBLESHOOTING If the unit fails to operate check the following 1 Is the unit connected to a live power source 2 Check the circuit breaker 3 Is the power switch on and pilot light glowing 4 Check the data plate Are you operating the unit on the proper voltage If the above checks ou...

Страница 6: ... the power switch is turned on and the timer is set to zero This mode will keep product above 150ºF after a HEAT cycle has finished HEAT MODE HEAT mode is on when the timer is set to an allotted time After the HEAT Cycle ends and the timer hits zero the unit will automatically enter HOLD mode Some experimentation will be necessary in determining heat times The quantity and type of product in the d...

Страница 7: ...7 EXPLODED VIEW SPTU ...

Страница 8: ...8 EXPLODED VIEW CONTINUED SPTU ...

Страница 9: ...5 25000065 25000145 25000045 WELDMENT DRAWER COVER 1 15 25000169 25000069 25000149 25000049 PAN DRAWER 1 16 8353200 SAME SAME SAME RIVNUT 1 4 20 THIN HEAD 4 17 8507600 SAME SAME SAME WASHER FLAT 1 4 8 18 8641500 SAME SAME SAME BEARING STAINLESS ROLLER SLIDES 4 19 8354000 SAME SAME SAME RIVET POP 1 8 SS 10 20 25000185 25000085 25000195 25000095 INSULATION TOP 1 1 21 25000186 25000086 25000196 25000...

Страница 10: ...AME SAME SCREW MACH 6 32 X 1 4 LG 2 42 8400100 SAME SAME SAME NUT HEX KEPS 6 32 4 43 8839110 SAME SAME SAME LABEL CAUTION HOT SURFACE 2 44 8861000 SAME SAME SAME LABEL SPEC 1 45 8130000 SAME SAME SAME 8 32 X 3 8 TYPE T 7 46 8506000 SAME SAME SAME LOCKWASHER EXT TOOTH 10 1 47 8422400 SAME SAME SAME 10 24 HX NUT GRN 1 48 1196000 SAME SAME SAME CONNECTOR WIRE SETSCREW 11 2 49 8967400 SAME SAME SAME S...

Страница 11: ...11 WIRING SCHEMATIC ...

Страница 12: ...12 NOTES ...

Страница 13: ...he conclusion of this warranty period portable units must be taken to or sent prepaid to the APW Wyott Authorized Service Agency for in warranty repairs No mileage or travel charges are allowed on portable units after the first day of use If the customer wants on site service they may receive same by paying the travel and mileage charges Exceptions to this rule 1 countertop warmers and cookers whi...