Page 16
Translation of the original operating manual
Put down the implement in a way that the tines are not needlessly strained (roller all the way
down, use the parking supports at the front).
10.2 Regular maintenance instructions
All bolted connections should be re-tightened at the latest after 3 operating hours and again after
20 hours, and then checked regularly (loose bolts can cause significant consequential damage,
which is not covered by the warranty).
The grease points on the joints and bearings must be lubricated regularly (approx. every 10
operating hours with universal grease).
Regular visual inspection of the tine safety must be performed.
For implements with fast coupler, the guide slots must also be lubricated.
After the first 10 operating hours and subsequently every 50 operating hours, the hydraulic units,
hydraulic hoses and couplings must be checked for leaks and the bolted connections must be
tightened if necessary.
Hydraulic hose lines must be replaced at the latest 6 years after their manufacturing date.
The manufacturing date of the hydraulic hose lines is specified on the fittings.
The platform kit and its access ladder must be visually inspected on a regular basis.
The rubber for fastening the access ladder of the platform kit must be checked regularly for wear
and replaced if necessary. It should only be replaced by trained specialist personnel and with
original parts.
10.3 Changing the tines
To replace broken or worn tines, all you have to do is loosen the nut and take out the tine (10 or
12 mm tines).
As shown in Fig. 9, you must hook on the new 10 or 12 mm tines and re-tighten the nuts.
Pay attention to the proper line distance! The tines in the rear row cut the distance of the front
tines in half.
Fig. 9
1: Unscrew the nut
2: Hook for fixing