Status messages and possible solutions 

3.1  Controller messages 

 
Error  messages  must  be  acknowledged  with  the  on/off  button  and  the  spreader  is 
then switched off.  
 
The following error messages can be displayed: 

 
CAUTION:

 If your battery is charged by a charger that is in "Start" operating mode, 

there  can  be  voltage  peaks!  These  can  cause  damage  to  the  electrical  system  of 
the control box if it is also connected when the battery is being charged! 

Display 

Cause 

Solutions 

E01  

 

Indicates  that  the  gear  motor  for  the 
seeding shaft is not connected.  

Check  the  cables  and  plugs  for 
faults or damage. 

E02  

 

Is  displayed  when  the  seeding  shaft 
cannot  rotate  or  when  the  motor  is 
strained for too long at its limits. 

Turn off the implement and check 
if solid substances or similar 
prevent the seeding shaft or 
agitator from turning or impede 
their operation. 

E03  

 

Is 

displayed 

when 

the 

motor 

(seeding shaft) is connected and not 
overloaded, but is still blocked. 

Check if there is something 
blocking the seeding shaft. If this 
is not the cause of the problem, 
please contact Customer 
Service. 

E01  

 

Indicates  that  the  blower  fan motor  / 
spreading 

plate 

motor 

is 

not 

connected.  

Check  the  programming  (see 
Point 7) and the cabling or plug. 

E02 

 

Indicates  that  the  blower  fan motor  / 
spreading  plate  motor  cannot  rotate 
or  that  the  blower  fan  motor  / 
spreading  plate  motor  is  being 
strained for too long at its limits. 

Turn off the implement and check 
if objects are blocking the blower 
fan / spreading plate or impeding 
their operation. 

E03 

 

Is  displayed  when  the  motor  (fan  or 
spreading  plate)  is  connected  and 
not  overloaded,  but  still  does  not 
rotate.  
For  hydraulic  fan  with  pressure 
switch or pressure sensor: the fan is 
not running or is not sending a signal 
to the pressure switch/speed sensor. 

For hydraulic fan: Switch on the 
hydraulic fan.  
Please contact customer service. 
 

E04 

Is  displayed  when  the  operating 
voltage is too low. 

Reduce  the  consumers,  check 
battery;  check  cabling,  check 
alternator 

Содержание 1.2

Страница 1: ...Translation of the original operating manual 1 2 Read carefully before initial operation Version 12 2018 V 1 2 Order no 00601 3 135 ...

Страница 2: ...concerned would then not only cause damage to himself but also make the mistake of assuming that the cause of any problems is due to the implement instead of himself To ensure success one has to go into the spirit of things and instruct oneself about the purpose of all equipment on the implement and gain experience with its handling Only then can one be satisfied both with the implement and onesel...

Страница 3: ... Emptying the hopper 8 2 8 Spreading disc speed chart 8 2 9 Automatic implement shut off 8 3 Status messages and possible solutions 9 3 1 Controller messages 9 3 2 Assistance in the event of problems 10 4 Cleaning 10 5 Decommissioning storage and disposal 10 5 1 Decommissioning the implement 10 5 2 Storage 10 5 3 Disposal 10 6 Accessories 11 6 1 Tractor cable set Item no 00410 2 022 11 7 Programmi...

Страница 4: ...if damage is caused by external forces e g opening of the controller if the control box is opened in cases of operating errors if the prescribed requirements are not met if the implement is modified expanded or equipped with third party spare parts without our permission 2 Quick start 2 1 Scope of delivery and attachment Fasten the standard supplied bracket with two bolts in the tractor cab TIP Pa...

Страница 5: ...wer socket tractor retrofitting 8 m long item no 00410 2 022 accessory IMPORTANT INFORMATION The 12 volt power supply must NOT be connected to the socket for the cigarette lighter CAUTION If these instructions are not observed damage may be caused to the control box CAUTION If your battery is charged by a charger that is in Start operating mode there can be voltage peaks These can cause damage to ...

Страница 6: ...ate is switched on 6 Blower fan button turns the blower fan or spreading plate on or off Not possible with hydraulic fan 7 Seeding shaft button turns the seeding shaft on or off When pressing the seeding shaft button the seeding shaft starts rotating and the control lamp lights up 8 Lights up when the seeding shaft is switched on The LED flashes when 0 is set as the speed on the rotary knob and th...

Страница 7: ...hes the blower fan motor or spreading plate is starting up 2nd Stage after a few seconds the LED control lamp beside the blower fan button lights up blower fan motor is running 3rd Stage when the green LED control lamp beside the seeding shaft button lights up the gear motor that turns the seeding shaft and conveys the seed is switched on When you are turning at the headlands you only have to pres...

Страница 8: ...red off After 3 seconds the calibration test begins 1 short beep By pressing and holding the button for an additional 3 seconds the module switches to drain mode the seeding shaft turns at full speed short beep 2 times You can stop a running function at any time by pressing the blower fan button or on off button 2 8 Spreading disc speed chart This table shows you the spreading disc speed depending...

Страница 9: ...n the motor seeding shaft is connected and not overloaded but is still blocked Check if there is something blocking the seeding shaft If this is not the cause of the problem please contact Customer Service E01 Indicates that the blower fan motor spreading plate motor is not connected Check the programming see Point 7 and the cabling or plug E02 Indicates that the blower fan motor spreading plate m...

Страница 10: ... Hydraulic fan is running E03 is still lit Is there no pressure switch installed Programming see point 7 4 Cleaning Use a dry cloth to clean the control box Do not use any aggressive solvent This may damage the implement 5 Decommissioning storage and disposal 5 1 Decommissioning the implement Switch off the control box using the on off button Disconnect the control box from the power supply after ...

Страница 11: ... 5 mm cable Ignition plus Black 6 mm cable Ground For the power supply to the control box without a standard 3 pin standard socket on the tractor a retrofit kit is available as an accessory The cable is 8 m long It is screwed directly on the terminals of the battery on the battery side and at the other end a 3 pin standard socket is installed Fig 5 ...

Страница 12: ...e Press and hold the on off button and briefly press the blower fan button at the same time see Fig 6 When pressing the blower fan button repeatedly the menu points switch from E01 through E05 By pressing the on off button or the seeding shaft button the selection is confirmed E01 Electric fan standard configuration E02 Hydraulic fan with pressure switch E03 Spreading plate MDS UD E04 Hydraulic fa...

Страница 13: ...fly press the seeding shaft button at the same time see Fig 7 Repeatedly pressing the seeding shaft button switches between settings E01 P8 gear motor or E02 P17 gear motor E01 P8 gear motor standard setting for pneumatic seed drills PS 120 500 for multi metering systems MDG MDP MDS MDC E02 P17 gear motor for pneumatic seed drills PS800 PS1200 and PS1600 for universal metering unit series UD The s...

Страница 14: ...14 Quality for Professionals Notes ...

Страница 15: ...15 Quality for Professionals Notes ...

Страница 16: ...lity for Professionals Inspired by Farmers realized by Professionals APV Technische Produkte GmbH HEADQUARTERS Dallein 15 AT 3753 Hötzelsdorf Tel 43 0 2913 8001 Fax 43 0 2913 8002 www apv at office apv at ...

Отзывы: