2.4  Starting up the implement 

 
After switching on the implement with the on/off button, the control lamp above the 
button lights up. This shows that the supply voltage is available. 
As long as the on/off button is held, the software version is displayed. E01 =Software 
1.1; E02= Software 1.2. This may be necessary in case of customer service. 
 
You can now use the rotary knob on the left to adjust the speed of the blower fan / 
spreading plate. The rotary knob on the right is used to adjust the speed of the 
seeding shaft. 
 
When you press the blower fan button, the fan motor (or the spreading plate on the 
MDS) will start running. 
 
As soon as you press the seeding shaft button, the seeding shaft starts rotating at 
the set speed and you can start seeding. 
 

2.5  Operation on the field 

 
To begin sowing, press the seeding shaft button. 
 

1st Stage:

 the LED control lamp beside the blower fan button flashes (the blower fan 

motor or spreading plate is starting up). 
 

2nd Stage:

 after a few seconds, the LED control lamp beside the blower fan button 

lights up (blower fan motor is running). 
 

3rd Stage:

 when the green LED control lamp beside the seeding shaft button lights 

up, the gear motor that turns the seeding shaft and conveys the seed is switched on. 
 
When you are turning at the headlands, you only have to press the seeding shaft 
button so that the green LED control lamp is turned off. This stops the seeding shaft 
and only the fan motor is still running. 
 
When finishing work, press the on/off button on the control box to switch off the fan 
motor and the seeding shaft. The LEDs are turned off and the control box is switched 
off.  
 

2.6  Calibration test 

 
First determine the required speed for the seeding shaft based on the calibration 
table (this can be found in the operating manual for the spreader).  
 
The calibration test is started by pressing and holding the seeding shaft button for 
3 seconds. The implement beeps once.  
 

PLEASE NOTE:

 Always ensure that the blower fan is switched off before starting the 

calibration test. 
 

Содержание 1.2

Страница 1: ...Translation of the original operating manual 1 2 Read carefully before initial operation Version 12 2018 V 1 2 Order no 00601 3 135 ...

Страница 2: ...concerned would then not only cause damage to himself but also make the mistake of assuming that the cause of any problems is due to the implement instead of himself To ensure success one has to go into the spirit of things and instruct oneself about the purpose of all equipment on the implement and gain experience with its handling Only then can one be satisfied both with the implement and onesel...

Страница 3: ... Emptying the hopper 8 2 8 Spreading disc speed chart 8 2 9 Automatic implement shut off 8 3 Status messages and possible solutions 9 3 1 Controller messages 9 3 2 Assistance in the event of problems 10 4 Cleaning 10 5 Decommissioning storage and disposal 10 5 1 Decommissioning the implement 10 5 2 Storage 10 5 3 Disposal 10 6 Accessories 11 6 1 Tractor cable set Item no 00410 2 022 11 7 Programmi...

Страница 4: ...if damage is caused by external forces e g opening of the controller if the control box is opened in cases of operating errors if the prescribed requirements are not met if the implement is modified expanded or equipped with third party spare parts without our permission 2 Quick start 2 1 Scope of delivery and attachment Fasten the standard supplied bracket with two bolts in the tractor cab TIP Pa...

Страница 5: ...wer socket tractor retrofitting 8 m long item no 00410 2 022 accessory IMPORTANT INFORMATION The 12 volt power supply must NOT be connected to the socket for the cigarette lighter CAUTION If these instructions are not observed damage may be caused to the control box CAUTION If your battery is charged by a charger that is in Start operating mode there can be voltage peaks These can cause damage to ...

Страница 6: ...ate is switched on 6 Blower fan button turns the blower fan or spreading plate on or off Not possible with hydraulic fan 7 Seeding shaft button turns the seeding shaft on or off When pressing the seeding shaft button the seeding shaft starts rotating and the control lamp lights up 8 Lights up when the seeding shaft is switched on The LED flashes when 0 is set as the speed on the rotary knob and th...

Страница 7: ...hes the blower fan motor or spreading plate is starting up 2nd Stage after a few seconds the LED control lamp beside the blower fan button lights up blower fan motor is running 3rd Stage when the green LED control lamp beside the seeding shaft button lights up the gear motor that turns the seeding shaft and conveys the seed is switched on When you are turning at the headlands you only have to pres...

Страница 8: ...red off After 3 seconds the calibration test begins 1 short beep By pressing and holding the button for an additional 3 seconds the module switches to drain mode the seeding shaft turns at full speed short beep 2 times You can stop a running function at any time by pressing the blower fan button or on off button 2 8 Spreading disc speed chart This table shows you the spreading disc speed depending...

Страница 9: ...n the motor seeding shaft is connected and not overloaded but is still blocked Check if there is something blocking the seeding shaft If this is not the cause of the problem please contact Customer Service E01 Indicates that the blower fan motor spreading plate motor is not connected Check the programming see Point 7 and the cabling or plug E02 Indicates that the blower fan motor spreading plate m...

Страница 10: ... Hydraulic fan is running E03 is still lit Is there no pressure switch installed Programming see point 7 4 Cleaning Use a dry cloth to clean the control box Do not use any aggressive solvent This may damage the implement 5 Decommissioning storage and disposal 5 1 Decommissioning the implement Switch off the control box using the on off button Disconnect the control box from the power supply after ...

Страница 11: ... 5 mm cable Ignition plus Black 6 mm cable Ground For the power supply to the control box without a standard 3 pin standard socket on the tractor a retrofit kit is available as an accessory The cable is 8 m long It is screwed directly on the terminals of the battery on the battery side and at the other end a 3 pin standard socket is installed Fig 5 ...

Страница 12: ...e Press and hold the on off button and briefly press the blower fan button at the same time see Fig 6 When pressing the blower fan button repeatedly the menu points switch from E01 through E05 By pressing the on off button or the seeding shaft button the selection is confirmed E01 Electric fan standard configuration E02 Hydraulic fan with pressure switch E03 Spreading plate MDS UD E04 Hydraulic fa...

Страница 13: ...fly press the seeding shaft button at the same time see Fig 7 Repeatedly pressing the seeding shaft button switches between settings E01 P8 gear motor or E02 P17 gear motor E01 P8 gear motor standard setting for pneumatic seed drills PS 120 500 for multi metering systems MDG MDP MDS MDC E02 P17 gear motor for pneumatic seed drills PS800 PS1200 and PS1600 for universal metering unit series UD The s...

Страница 14: ...14 Quality for Professionals Notes ...

Страница 15: ...15 Quality for Professionals Notes ...

Страница 16: ...lity for Professionals Inspired by Farmers realized by Professionals APV Technische Produkte GmbH HEADQUARTERS Dallein 15 AT 3753 Hötzelsdorf Tel 43 0 2913 8001 Fax 43 0 2913 8002 www apv at office apv at ...

Отзывы: