APT MHC 5 Скачать руководство пользователя страница 17

MHC 5

17

(doc no.)

SAFETY & OPERATING INSTRUCTIONS

Technical data

Troubleshooting

Solution

Cause

Problem

Check the performance and connection of

the power source. Make sure that the return

line coupling is completely fitted with no

clearance

Core drill not connected properly

Core drill will not operate

Check the power source and ensure that the

flow and pressure are according to the

technical specifications

Oil flow and/or pressure too low

Check the power source and ensure that the

flow and pressure are according to the

technical specifications

Oil flow and/or pressure too low

Core drill runs at low speed

Clean system

Contaminated hydraulic system

Carefully check the O-ring seals in the trigger

valve bushing and replace damaged ones

Internal leakage

Tighten trigger valve bushing properly

Untightened trigger valve bushing

Core drill runs without pushing the trigger

Replace the O-ring at the bottom of the

trigger valve bushing hole

O-ring failure

Replace spring

Check valve spring broken

Check the power source and ensure that the

flow and pressure are according to the

technical specifications - and that the

connections are correct

Flow too high

Trigger lever stuck

Improper pressure/return line connection
Back pressure too high

Check trigger valve/reversing valve for

seizing

Impurities

Readjust the flat spring through the two

screws on the motor housing

Trigger lever blocked in locked position

Trigger lever cannot be released

Reduce the flow from the power source. If

necessary, use a flow divider to control the

flow

Flow too high

System overheats

Use a power source with higher cooling

capacity or add an additional oil cooler in the

return line

Insufficient cooling

Machine data

COR 5, COR 15

7 (15.4)

Weight without hoses and drill bit, kg (lb)

20-30 (5-8)

Oil flow range, l.p.m. (US gal/min)

160 (2300)

Maximum pressure relief valve setting, bar (psi)

C and D

EHTMA category

14 (200)

Maximum back pressure in return line, bar (psi)

30-70 (86-158)

Oil working temperature, °C (°F)

Approx. 2

Required cooling capacity, kW

30 l.p.m. (8 US gal/min)

20 l.p.m. (5 US gal/min)

Drill bit diameter mm (in.)

rpm

Drill bit diameter mm (in.)

rpm

Type

50-100 (2-4)

900

75-202 (3-8)

600

COR 5

12-30 (0.5-1.2)

2250

25-75 (1-3)

1500

COR 15

17

3392 5192 90a | Original instructions

Safety and operating instructions

COR 5, 15

Содержание MHC 5

Страница 1: ...Safety Operating Instructions Handheld Core Drill MHC 5 AMERICAN PNEUMATIC TOOLS...

Страница 2: ...MHC 5 2 doc no SAFETY OPERATING INSTRUCTIONS 3392 5164 01c 2 5 15...

Страница 3: ...Installation 13 Hoses 13 Quick release couplings 14 Hydraulic oil 14 Pressure adjustment 14 Water flushing 14 Drill bit 14 Operation 15 Preparations before starting 15 Start and stop 15 Operating 15...

Страница 4: ...MHC 5 4 doc no SAFETY OPERATING INSTRUCTIONS...

Страница 5: ...erators compressors pumps and a whole lot more The American Pneumatic Tools brand is associated with powerful and reliable products that are easy to maintain and that give good value for the money For...

Страница 6: ...et Hearing protection Impact resistant eye protection with side protection Respiratory protection when appropriate Protective gloves Proper protective boots Appropriate work overall or similar clothin...

Страница 7: ...when it is lying on the ground Never ride on the machine with one leg over the handle Never strike or abuse the equipment Check regularly for wear on the insertion tool and check whether there are an...

Страница 8: ...ommended in the operating and safety instructions Select maintain and replace consumables inserted tools other accessory as recommended in the operating and safety instructions Incorrect selection or...

Страница 9: ...r fingers to check for hydraulic fluid leaks Keep your face away from any possible leaks WARNING Vibration hazards Normal and proper use of the machine exposes the operator to vibration Regular and fr...

Страница 10: ...for hydraulic fluid leaks Keep your face away from any possible leaks WARNING Vibration hazards Normal and proper use of the machine exposes the operator to vibration Regular and frequent exposure to...

Страница 11: ...ediately Replace worn components in good time CAUTION Hot insertion tool The tip of the insertion tool can become hot and sharp when used Touching it can lead to burns and cuts Never touch a hot or sh...

Страница 12: ...ousing is designed with a 60 mm cylindrical surface that fits into industry standard drilling rig mounting collars The directly driven hydraulic power design provides consistent rotation and torque wh...

Страница 13: ...s the guaranteed noise level corresponding to EC directive 2000 14 EC See Technical data for accurate noise level EHTMA category The machine is clearly marked with EHTMA categories It is important tha...

Страница 14: ...the oil can then be used within a wider temperature range The machine must not be used if oil viscosity fails to remain within the permitted area or if the working temperature of the oil does not fall...

Страница 15: ...any that are missing or cannot be read Ensure that the hydraulic couplings are clean and fully serviceable Ensure that the fittings are tight and leak proof Always use the core drill with a front hand...

Страница 16: ...ction caused by the use of unauthorised parts is not covered by warranty or product liability When cleaning mechanical parts with solvent comply with appropriate health and safety regulations and ensu...

Страница 17: ...e and ensure that the flow and pressure are according to the technical specifications and that the connections are correct Flow too high Trigger lever stuck Improper pressure return line connection Ba...

Страница 18: ...rdance with the same directive or standards These declared values are not suitable for use in risk assessments and values measured in individual work places may be higher The actual exposure values an...

Страница 19: ...achinery Directive and the harmonised standards mentioned below Pmax bar Hydraulic core drill 160 COR 5 160 COR 15 Following harmonised standards were applied ISO FDIS 11148 3 2009 Technical Documenta...

Страница 20: ...AMERICAN PNEUMATIC TOOLS 800 532 7402 fax 800 715 6502 1000 S Grand Ave Santa Ana CA 92705...

Отзывы: