Quick-release couplings

The original hydraulic hoses are fitted with Flat-Face

quick-release couplings that are strong and easy to

clean. The quick-release couplings are fitted so that

the male connection supplies oil and the female

connection receives oil.

NOTICE   

Wipe all couplings clean before

connecting. Ensure that couplings are clean and

correctly engaged before operation. Failure to do so

may result in damage to the quick couplings and

cause overheating and cause foreign matter to enter

the hydraulic system.

Hydraulic oil

In order to protect the environment, Atlas Copco

recommends the use of biologically degradable

hydraulic oil. No other fluids must be used.

Viscosity (preferred) 20-40 cSt.

Viscosity (permitted) 15-100 cSt.

Viscosity index Min. 100.

Standard mineral or synthetic oil can be used. Make

sure to only use clean oil and filling equipment.
When the machine is used continuously, the oil

temperature will stabilise at a level which is called

the working temperature. This will, depending on

the type of work and the cooling capacity of the

hydraulic system, be between 20-40°C (68-104°F)

above the ambient temperature. At working

temperature, the oil viscosity must lie within the

preferred limits. The viscosity index indicates the

connection between viscosity and temperature. A

high viscosity is therefore preferred, because the oil

can then be used within a wider temperature range.

The machine must not be used, if oil viscosity fails

to remain within the permitted area, or if the

working temperature of the oil does not fall between

20°C (68°F) and 70°C (158°F).

Pressure adjustment

The maximum pressure of the power source is

important. The pressure created in case of an

incorrectly or unfitted return line coupling would

cause overloading. Which could harm the machine

and result in bodily injuries. The maximum pressure

of the power source is 160 bar (limited by safety

valve adjustment).

WARNING    Operating pressure

If the maximum operating pressure for the hydraulic

machine is exceeded, it can result in material damage

and personal injury.

Always run the hydraulic machine with the correct

operating pressure, see "Technical data".

Only readjust the pressure relief valve (torque

control) on the machine according to procedure

and values described under maintenance. Note

that higher settings might lead to a higher torque,

which could harm the machine and result in

serious injury or death.

Water flushing

For diamond bit core drilling, water flushing is

required. Mount the water swivel and water hose

on the core drill as follows.

The water can be supplied directly from a source,

or a separate water kit can be used. A separate water

kit with pressure tank is available, see the spare parts

list.

Drill bit

Choosing drill bit

A correct drill bit is a condition for good operation.

To avoid unnecessary machine damage, it is

important to choose drill bits with a high quality.

3392 5192 90a | Original instructions

14

COR 5, 15

Safety and operating instructions

Содержание MHC 5

Страница 1: ...Safety Operating Instructions Handheld Core Drill MHC 5 AMERICAN PNEUMATIC TOOLS...

Страница 2: ...MHC 5 2 doc no SAFETY OPERATING INSTRUCTIONS 3392 5164 01c 2 5 15...

Страница 3: ...Installation 13 Hoses 13 Quick release couplings 14 Hydraulic oil 14 Pressure adjustment 14 Water flushing 14 Drill bit 14 Operation 15 Preparations before starting 15 Start and stop 15 Operating 15...

Страница 4: ...MHC 5 4 doc no SAFETY OPERATING INSTRUCTIONS...

Страница 5: ...erators compressors pumps and a whole lot more The American Pneumatic Tools brand is associated with powerful and reliable products that are easy to maintain and that give good value for the money For...

Страница 6: ...et Hearing protection Impact resistant eye protection with side protection Respiratory protection when appropriate Protective gloves Proper protective boots Appropriate work overall or similar clothin...

Страница 7: ...when it is lying on the ground Never ride on the machine with one leg over the handle Never strike or abuse the equipment Check regularly for wear on the insertion tool and check whether there are an...

Страница 8: ...ommended in the operating and safety instructions Select maintain and replace consumables inserted tools other accessory as recommended in the operating and safety instructions Incorrect selection or...

Страница 9: ...r fingers to check for hydraulic fluid leaks Keep your face away from any possible leaks WARNING Vibration hazards Normal and proper use of the machine exposes the operator to vibration Regular and fr...

Страница 10: ...for hydraulic fluid leaks Keep your face away from any possible leaks WARNING Vibration hazards Normal and proper use of the machine exposes the operator to vibration Regular and frequent exposure to...

Страница 11: ...ediately Replace worn components in good time CAUTION Hot insertion tool The tip of the insertion tool can become hot and sharp when used Touching it can lead to burns and cuts Never touch a hot or sh...

Страница 12: ...ousing is designed with a 60 mm cylindrical surface that fits into industry standard drilling rig mounting collars The directly driven hydraulic power design provides consistent rotation and torque wh...

Страница 13: ...s the guaranteed noise level corresponding to EC directive 2000 14 EC See Technical data for accurate noise level EHTMA category The machine is clearly marked with EHTMA categories It is important tha...

Страница 14: ...the oil can then be used within a wider temperature range The machine must not be used if oil viscosity fails to remain within the permitted area or if the working temperature of the oil does not fall...

Страница 15: ...any that are missing or cannot be read Ensure that the hydraulic couplings are clean and fully serviceable Ensure that the fittings are tight and leak proof Always use the core drill with a front hand...

Страница 16: ...ction caused by the use of unauthorised parts is not covered by warranty or product liability When cleaning mechanical parts with solvent comply with appropriate health and safety regulations and ensu...

Страница 17: ...e and ensure that the flow and pressure are according to the technical specifications and that the connections are correct Flow too high Trigger lever stuck Improper pressure return line connection Ba...

Страница 18: ...rdance with the same directive or standards These declared values are not suitable for use in risk assessments and values measured in individual work places may be higher The actual exposure values an...

Страница 19: ...achinery Directive and the harmonised standards mentioned below Pmax bar Hydraulic core drill 160 COR 5 160 COR 15 Following harmonised standards were applied ISO FDIS 11148 3 2009 Technical Documenta...

Страница 20: ...AMERICAN PNEUMATIC TOOLS 800 532 7402 fax 800 715 6502 1000 S Grand Ave Santa Ana CA 92705...

Отзывы: