140
11.4.13
Ethernet Card Settings Commands and Companion Queries
Command
Name
Value
SIM {1|0}
SIM?
Set IP Mode
1=Manual, 0=Auto
(DHCP/BOOTP)
SIA <value>
SIA?
Set IP Address
Dotted decimal form. Ex.
192.168.1.50
SGA <value>
SGA?
Set Gateway IP
Address
Dotted decimal form
SSM <value>
SSM?
Set Subnet Mask
Dotted decimal form
SDN <value>
SDN?
Set Device Name
8 character max, must start with
a letter
MAC?
MAC Address Query
Example response:
00:20:4A:8B:B4:30
SBI {4|3|2|1|0}
SBI?
Set Barcode Input
0=Off, 1=Serial# and Product#,
2=Serial# Only, 3=Product#
Only, 4=Run File
SAS {1|0}
SAS?
Set Autostart
1=On, 0=Off
Communication Considerations
•
All of the above commands (excluding the query commands) will respond
with the 06 hex (6 decimal) Acknowledge (ACK) ASCII control code if the
transfer was recognized by the instrument.
•
If there was an error with the command string, the instrument will respond
with 15 hex (21 decimal), the Not Acknowledge (NAK) ASCII control code.
•
However, the presence of this response does not mean that the
instrument (in the case of these commands only) completed the
command. These commands require a restarting of the hardware that
controls the Ethernet Protocols. Because of this, the user must wait
before the Ethernet Card will respond to another command. See the table
below for the approximate wait times necessary after one of the
commands in the table is sent. In addition, the current socket connection
between the user’
s terminal and the Ethernet Card is no longer valid, and
the user will need to close their current connection and establish a new
one.
Содержание 310XAC
Страница 13: ...13 320XAC 340XAC...
Страница 116: ...116 1 Test Complete OK WAI Wait for next command...
Страница 119: ...119 masks from non volatile memory at power ON PSC Queries the power on status clear setting Returns 0 or 1...
Страница 146: ...146 14 Schematics Index Unless specified in the Model column of this table schematics are valid for all models...