![Aprimatic R1-24 Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/aprimatic/r1-24/r1-24_installation-use-and-maintenance-instructions_2956745028.webp)
-
28
-
English
4.3 PROGRAMMABLE
PARAMETERS
DISPLAY
FUNCTION
VALUES
DEFAULT
Basic menu
(default to the right of the dot)
LO
Logic
0 = Automatic; 1 = 4 steps; 2 = Super automatic;
3 = Semi-automatic with stop; 4 = Step-by-step;
5 = Manned; 6 = Timer (start input)
0 - 6
0.
(automatic)
PA
Pause time (0”- 60”) (1 step =1”)
0 - 60
25.
En.
Force (thrust force on obstacle) (0 = overridden)
0 - 5
2.
SPE.
Wing speed (0=50% ; 1=70% ; 2=85% ; 3=100% maximum speed)
0 - 3
2.
ElS.
Electric lock (0=disabled; 1=enabled)
0 - 1
0.
(disabled)
LAm.
Pre-
fl
ashing time (0”- 9”) (1 step =1”)
0 - 9
3
PSET
Restore factory settings (default)
Red button to con
fi
rm
PRoF
To enter programming mode
Red button to con
fi
rm
Advanced menu
(the 3rd and 4th digits indicate the default value)
A1
Wing 1 delay during closing (0°-75°) (1 step = 5° displacement approx.)
00 - 15
05.
(approx 25°)
A2
Wing 2 delay during opening (0°-10°) (1 step = 2.5° displacement approx.)
01 - 05
02.
(approx. 5°)
A3
Pedestrian wing opening (20% - 100%) (1 step = 20%)
00 - 04
04.
(opens everything)
A4
Electric lock operation time (3.0”- 5.0”) (1 step = 0.5”)
3.0 - 5.0
3.0.
(3.0”)
A5
Electric lock advance (0” - 1”) (1 step = 0.5”)
00 - 1.0
0.5.
A6
Reverse stroke time (0”- 2”) (1 step = 0.5”) with autoset 1” if electric lock
fi
tted
0.0 - 2.0
0.0.
(disabled)
A7
Obstacle masking time at start-up (3”- 6”) (1 step = 0.5”)
3.0 - 6.0
3.0.
A8
Reverse time at end of movement (0mSec- 400mSec) (1=30; 2=50;
3=80; 4=100; 5=120; 6=150; 7=200; 8=300; 9=400)
00 - 09
00.
(disabled)
A9
Approach speed (50% - 80% cruising speed) (1 step = 10%)
00 - 03
01.
(60%)
AA
Start ramp incline (0 = max acceleration; 4 = minimal acceleration)
00 - 04
02.
Ab
Brake ramp incline (0 = max brake; 4 = minimal brake)
00 - 04
02.
Ac
Approach distance (5°-22,5°) (1 step = 2.5°)
02 - 09
03.
(7°)
Ad
Closing when the photocell is no longer covered occurs:
00= immediately
01= at the end of the pause time (counting continues)
02= after 10”
03= after a complete new period of pause time (reloads the pause time)
00 - 03
01.
(at the end of the
pause time)
AE
-
-
-
AF
Emergency functioning with batteries in the event of mains power failure
(slow wing speed, increased
fl
ashing light speed)
00 = the gate can perform 3 cycles and then stops functioning
01 = the gate can perform 3 cycles and then stops open
02 = the gate opens and stays open (safety functioning)
00 - 02
00.
(3 cycles can be
performed)
AH
Flashing light ON during pause time
00 = disabled (only automatic functioning); 01 = enabled
00 - 01
00.
(disabled)
AM
-
-
-
At
Windproof: recovery of structure elasticity in case of pressure changes (wind)
0 = disabled; 1 = enabled
-
-
Ap
-
-
-
Ar
Safety device during opening: (00 = safety edge; 01 = photocell)
00 - 01
01.
(photocell)
AU
Self adjusment (0=disabled ; 1=enabled)
0 - 1
0.
(disabled)
Red
Blue
To select
Yellow
To exit
To con
fi
rm
IMPORTANT NOTE:
ALt
Shows the total number of counter opening operations (1 step =100 cycles).
0000-9999
-
ALP
Shows the number of counter maintenance partial operations (x 10 cycles).
Flashing if in OVERFLOW.
0000-9999
-
ALS
Sets the counter maintenance cycle (x 10 operations) with minimum step of
100 operations. Each setting resets the maintenance cycle (
ALP
).
0000-9990
00.00
(no maintenance)
ALr
Resets the maintenance counter.
-
-
Basic and advanced programming
Содержание R1-24
Страница 87: ...87...