DS41035-001
27
LBT0197
6.5 REGULATIONS
The
TR1 DELAY
trimmer regulates the timing of the pause (the time the gate remains still before being closed
automatically), which varies from 1 to 120 seconds
The
TR2 TORQUE
trimmer regulates the torque of the motors.
REMARK
:
For motors equipped with a clutch or for oil-pressure motors it is necessary to rotate the TR2 TORQUE
trimmer to the maximum extent possible (i.e., a complete clockwise rotation).
The
TR3 SLACK
regulates the speed at which the timing is slowed, which can be regulated within the safety parameters.
REMARK
:
By regulating the TR3 SLACK trimmer to the maximum extent possible (i.e., a complete clockwise rotation),
the slowing does not take place (see learning procedure without slowing).
TRIMMER Function
Range
Special
functions
TR1
DELAY
Pause time
1 to 120 sec
-
TR2
TORQUE
Motors torque
20 to 100%
100% = clutch
TR3
SLACK
Slowing speed
0 to 100%
100% = no slowing
6.6
ACQUISITION REMOTE CONTROLS
The AP 350 equipment is equipped with a built-in decoder able to memorize up to 128 rolling-code remote controls in
addition to fixed-code remote controls
.
6.6.1 START
function
In closed-gate mode, press the
PROG.B
button and hold it down until the
TEST LED
starts to flash. Release the
PROG.B
button.
Within 10 seconds, set the remote control button that you want to connect to the
START
command. The completion of
the process will be indicated by the simultaneous flash of the
TEST LED
, of the flasher and of the pilot lamp, followed by
the termination of the flashing of the
TEST LED
.
With rolling code remote controls, repeat the process for each remote control to be set. With fixed-code remote controls it
is sufficient to carry out the process for only one model.
6.6.2 PEDESTRIAN
START
function
In closed-gate mode, press the
PROG.B
button and hold it pressed until the
TEST
led starts to flash; don’t release the
button and wait until the flashing speeds up. Release the
PROG.B
button.
Within 10 seconds set the button of the remote control to learn and to be connected with the
PEDESTRIAN START
control. When the learning has been carried out it will be indicated by the simultaneous flash of the
TEST
led, flasher
and of the pilot lamp, followed by the termination of the flashing of the
TEST
led.
In case of rolling code-type remote controls repeat the operation for each remote control to learn. In case of fixed-type
remote controls it is sufficient to carry out the learning of one single model.
6.6.3
Complete cancellation of the acquired remote controls
In closed-gate mode, press the
PROG.B
button and hold it pressed till when the
TEST
led starts to flash; don’t release
the button and wait until the flash gets quicker; don’t release the button and wait until the flash gets very quick; don’t
release the button. When the blanking /blackout of
ALL
the learned remote controls has been carried out it will be
indicated by the simultaneous flash of the
TEST
led, flasher and of the pilot lamp, followed by the termination of the
flashing of the
TEST
led.
6.7 MAINTENANCE
There are two 5x20-size fuses on the board that protect the 230V line and the secondary of the transformer.
The fuse have the following values
230V line
F1 =
5A
fast
Secondary F2
=
2A
fast
Before replacing the fuses it is necessary to turn off the 230V mains power supply. The
power of these fuses must not be modified.
There is no other component on the board that can be repaired or replaced by the installation personnel.
For any other intervention it is necessary to contact technical support.
Содержание G-matic AP350
Страница 13: ...DS41035 001 13 LBT0197 6 8 2 Acquisizione doppia anta con rallentamento ...
Страница 15: ...DS41035 001 15 LBT0197 6 9 2 Acquisizione doppia anta senza rallentamento ...
Страница 18: ...DS41035 001 18 LBT0197 AP 350 8 SCHEMA ELETTRICO APPARECCHIATURA ELETTRONICA AP350 ...
Страница 29: ...DS41035 001 29 LBT0197 6 8 2 Acquisition for double shutter with slowing ...
Страница 31: ...DS41035 001 31 LBT0197 6 9 2 Acquisition for double shutter without slowing ...
Страница 35: ...DS41035 001 35 LBT0197 AP 350 8 DIAGRAM AP 350 ELECTRONIC EQUIPMENT ...