DS41035-001
26
LBT0197
6.3 OPERATING
MODES
•
CONDOMINIUM AUTOMATIC
The gate is opened when the
START
button is pressed whether the gate is closed or being closed. The
START
command is ignored while the gate is being opened, whereas during the pause phase it makes the timing of this
phase restart. After pressing
STOP
, pressing
START
closes the gate.
•
SUPERAUTOMATIC
The gate is opened when the
START
button is pressed whether the gate is closed or being closed. While the gate is
being opened however it produces a
STOP
, after which a subsequent
START
closes the gate. During the pause
phase, pressing the
START
button closes the gate. After pressing
STOP
, pressing
START
closes the gate.
•
AUTOMATIC
The gate is opened when the
START
button is pressed whether the gate is closed or being closed. The
START
command is ignored while the gate is being opened, whereas during the pause phase it makes the gate close again.
After pressing
STOP
, pressing
START
closes the gate.
•
SEMIAUTOMATIC
The
START
button controls the opening, closing and halting of the gate. After it is opened, it is necessary to press
the
START
button to close it again. While the gate is being opened, pressing
START
halts the gate and another
pulse makes the gate close. If
START
is pressed during the closing phase the direction is inverted. After pressing
STOP
, pressing
START
closes the gate.
•
STEP BY STEP
The gate is opened when
START
pulse is pressed while the gate is closed.
The
START
command produces a
STOP
during the opening phase, subsequently pressing
START
causes the gate
to close, and pressing
START
again produces a
STOP
. After pressing
STOP
, pressing
START
closes the gate.
Select the operating mode using the
1
,
2
,
3
and
6
dip switches, with reference to the “OPERATING MODES SELECTION”
table (after each mode change it is necessary to short circuit
JR1
reset contacts for a few seconds so that the change
can take effect).
OPERATING MODES SELECTION
Dip 1
Dip 2
Dip 3
Dip 6
Mode
OFF OFF OFF OFF
Condominium
automatic
OFF
OFF
ON
OFF
Condominium aut comfort (1)
OFF ON OFF OFF
Superautomatic
OFF
ON
ON
OFF
Superaut comfort (1)
ON ON OFF
OFF
Automatic
ON ON ON OFF
Aut comfort (1)
ON OFF OFF OFF
Semiautomatic
ON
OFF
ON
OFF
Step by step
OFF OFF OFF ON
Condominium
aut photocell retrigger (2)
OFF
ON
OFF
ON
Superaut photocell retrigger (2)
ON ON OFF ON
Automatic
+ photocell retrigger (2)
(1):
The function
comfort
enables the gate to be closed 5 seconds after the photocells have received a pulse, regardless
of the timing of the pause setting.
(2):
The function
photocell
retrigger
makes the timing of the pause restart if the photocells are in use during the pause
itself.
6.4 SETTING
Through the
4
,
5
,
7
and
8
dip switches it is possible to configure certain functions of the equipment:
Dip switch
Function
ON
OFF
4 Preflashing
Enabled
Disabled
5 Release
stroke
Enabled
Disabled
7
Flash light type
With board
Lamp only
8 Closing
stroke
Enabled
Disabled
Содержание G-matic AP350
Страница 13: ...DS41035 001 13 LBT0197 6 8 2 Acquisizione doppia anta con rallentamento ...
Страница 15: ...DS41035 001 15 LBT0197 6 9 2 Acquisizione doppia anta senza rallentamento ...
Страница 18: ...DS41035 001 18 LBT0197 AP 350 8 SCHEMA ELETTRICO APPARECCHIATURA ELETTRONICA AP350 ...
Страница 29: ...DS41035 001 29 LBT0197 6 8 2 Acquisition for double shutter with slowing ...
Страница 31: ...DS41035 001 31 LBT0197 6 9 2 Acquisition for double shutter without slowing ...
Страница 35: ...DS41035 001 35 LBT0197 AP 350 8 DIAGRAM AP 350 ELECTRONIC EQUIPMENT ...
Страница 68: ...DS41035 001 68 LBT0197 ...