18
19
SETUP & TESTINg
Test steps for Heat/Cool
Step
Key Input
System Setting
Display (Output)
#07
01
HEATINg
ON (W)
02
HEATINg
ON (W2)
01
COOlINg
ON (Y)
02
COOlINg
ON (Y2)
01
FAN ON
(g)
#50 Heat
1st [UP]
0 : Gas
ON
1 : Elec
ON
ON
2nd [UP]
0 : Gas
ON
ON
1 : Elec
ON
ON
ON
[DOWN]
#52 Cool
1st [UP]
ON
ON
2nd [UP]
ON
ON
ON
[DOWN]
#53 Fan
[UP]
ON
[DOWN]
Test steps for Heat Pump
Step
Key Input
System Setting
Display (Output)
#07
#03
01 AUX
HEATINg
ON (W)
02 AUX
HEATINg
ON (W2)
01
COOl/HEAT
ON (Y)
02
COOl/HEAT
ON (Y2)
01
FAN ON
(g)
O/B
#50 Heat
1st [UP]
0 : O
ON
ON
1 : B
ON
ON
ON
2nd [UP]
0 : O
ON
ON
ON
1 : B
ON
ON
ON
ON
[DOWN]
0 : O
1 : B
ON
#51 Aux
1st [UP]
0 : Gas
ON
1 : Elec
ON
ON
2nd [UP]
0 : Gas
ON
ON
1 : Elec
ON
ON
ON
[DOWN]
#52 Cool
1st [UP]
0 : O
ON
ON
ON
1 : B
ON
ON
2nd [UP]
0 : O
ON
ON
ON
ON
1 : B
ON
ON
ON
[DOWN]
0 : O
ON
1 : B
#53 Fan
[UP]
ON
[DOWN]
SETUP & TESTINg