Do not modify this unit. Otherwise it may cause fire or electric shock

Do not open the unit

'

s casing. Otherwise it may cause electric shock. If you think the 

unit needs to be

 

checked

maintained or repaired, please contact the dealer.

If there is lightning, please turn off the unit as soon as possible, and unplug the power 
cable from the power outlet

.

When connect the speakers to the amplifier

'

s output jacks, only can use dedicated 

speaker cable. Using other cables may cause fire.

When connect the unit

please turn off all the musical instruments, audio equipments 

and speakers. Please use the correct cable, and connect it in accordance with 
regulations.

Before turning on the power supply of this unit, please be sure to spin the volume 
control to minimum. Otherwise, a sudden burst of sound may damage your hearing.

If you do not use the unit for a long period of time, please unplug the plug from the AC 
outlet. Otherwise it may cause fire.

If the power cord is damaged (such as cut or bare wire), please ask for a replacement

 

from the dealer

Otherwise, continue to use this unit that may cause fire or electric 

shock.

If this unit falls down from a height or the cover is damaged, please immediately turn 
off the unit and unplug the plug from the AC outlet, otherwise it may cause fire or 
electric shock. At the same time please contact the dealer.

When finding any abnormality, such as smoke, odor, noise or foreign matter and other 
liquid enter into the unit

please immediately turn off the power switch and unplug the 

power cord from the AC outlet. Otherwise, continue to use that may cause fire or 
electric shock. Please contact dealer for repair at the same time

.

For your safety and the unit to work properly, please strictly 
follow the manual's instructions for installation and operation!

IMPORTANT SAFETY INSTRUCTIONS

02

Σ

M

 

SERIES

 

PROFESSIONAL

 

POWER

 

AMPLIFIER

Содержание EM-4102

Страница 1: ...ituations that may arise during the maintenance The information provided in this manual is accurate when be sent out from the factory but now this manual may has been updated because of the product ch...

Страница 2: ...wise it may cause fire or electric shock Do not allow water to enter the unit or to make it damp Otherwise it may cause fire or electric shock Do not place a container with liquid or small metal objec...

Страница 3: ...use the unit for a long period of time please unplug the plug from the AC outlet Otherwise it may cause fire If the power cord is damaged such as cut or bare wire please ask for a replacement from the...

Страница 4: ...products 1 3 Symbol Description The exclamation mark within the triangle symbol is used to prompt the user to pay attention to the important operating or special instructions The lightning symbol with...

Страница 5: ...repare the following parts our company does not provide 1 Input wiring cable Output wiring cable 2 Ethernet cables individual series need to use the advanced features 3 Network router individual serie...

Страница 6: ...ircuit will reduce output power If the amplifier overheats the temperature protection detection circuit and its circuit will shut down and power off until it cools to a safe temperature After using th...

Страница 7: ...ration 2 3 4 Interface illustration Output connection Amplifier output Not connect XLR male plug typical pin assignment 1 1 2 2 2 2 1 1 2 HOT 1 SHIELD 3 COLD B A A A A 2 1 2 1 2 1 2 1 to PIN 1 to PIN...

Страница 8: ...evices such as tape deck above or below the unit directly This will form a strong magnetic field to cause a buzzing sound near the unshielded device If you use a cabinet we recommend you to place the...

Страница 9: ...stortion on the corresponding channel rises above 1 which indicate that the clipping has occurred because the signal level is too high Signal LED The corresponding LED will light up when the input sig...

Страница 10: ...s 1Vrms When it is on 32dB the amplification gain range is within 32dB When it is on 26dB the amplification gain range is within 26dB Mode Switch STEREO Mode Channel A and Channel B work independently...

Страница 11: ...4 Core parameter 1Vrms 32dB 26dB 1Vrms 32dB 26dB 483x390x44 483x390x44 parallel20k unparalle10k parallel20k unparalle10k 2dB 2dB 10 M SERIES PROFESSIONAL POWER AMPLIFIER...

Страница 12: ...he product within three 3 years purchased from the date you buying no matter what the reason is for any non human factors or the irresistible force effects caused the failure of the new products our c...

Страница 13: ...The product which has no body code or the code has been altered destroyed converted and not in our company s sales records In the following cases the warranty card will automatically expire 1 The prod...

Страница 14: ...ame Phone No Date Contact address Serial number Customer information Maintenance records Date Fault Processing condition Inspection date Mainte nance order No Maintainer Mainte nance place M SERIES PR...

Страница 15: ...Note DN SERIES PROFESSIONAL POWER AMPLIFIER...

Страница 16: ......

Отзывы: