11
6 Maintenance Cont’d.
m. The Solution needle (#10) can also be removed for additional maintenance. To remove: Turn the Solution
Flow Screw anti or counter clockwise until it comes out of the Spray Gun. Be careful when removing the
Solution Flow Screw as there is a small spring (#9) around the needle. Do not lose it. This is important to
the operation of the Spray Gun. Set the spring aside and pull the trigger all the way back until you can
grab the needle with your finger tips and pull it out from the back of the Spray Gun. Once removed, rinse
under warm running water, Clean and dry. Reinstall reversing the removal procedure.
NOTE:
Occasionally it is necessary to lubricate the needle (#10) where it slides through the gland nut
(#7). Simply rub a few drops of Spray Gun lube around the needle shaft and reinsert into the back of the
Spray Gun.