background image

 

 

 

 

2. GENERAL INFORMATION 
 

 

Before using the bed: 

·

 

Read through this whole manual in order to avoid causing damages to 

the bed due to improper use. 

 

Before using the nursing bed, the user must verify its perfect status and complete efficiency. 
This bed conforms to all the requirements of Directive 93/42/EEC for medical products and 

it is classified as a Class I medical device. 
 
This  manual  contains  safety  instructions  which  must  be  fully  respected.  All  the  people 

involved with using the bed must know the complete contents of this manual and observe 
the safety warnings listed herein. 
 
Information for the owner: 

·

 

Every  electrical  appliance  may  cause  hazards  if  used  incorrectly.  Therefore  it  is 

necessary to instruct the user on how to use the nursing bed correctly.  

·

 

Inform the user of where this manual will be kept. 

 

2.1 Groups of people mentioned in this manual  

 

The manual may refer to the following groups of people somehow involved with using the 
bed: 

·

 

Owner 
The  owner  (for  example:  suppliers  of  medical  products,  dealers,  health  care 
authorities, etc.) can be any physical person or juridical body which uses the nursing 

bed  or  under  whose  name  the  bed  is  being  used.  The  owner  is  responsible  for 
providing the necessary information to the user. 

 

·

 

User 
the  user  is  the  person  authorized  to  use  the  nursing  bed  and  to  carry  out  any 
operations on the bed on the basis of his/her training, experience or education, and 

who  has  been  trained  to  use  the  bed.  Furthermore,  the  user  must  be  able  to 
recognize and avoid potential hazards and evaluate the condition of the patient. 

 

 

Patient 
In this manual the term patient refers to the person who needs to be taken care of, 

who might be sick or disabled and therefore in need of using this bed. 

 

·

 

Specialized personnel 

The term specialized personnel refers to the owner’s co-operators who are 
authorized, on the basis of their training or education, to deliver and assemble.  

 

 
 

 
 
 

 

Содержание Bariatric Professional APH188

Страница 1: ...1 Electric Bed Apollo Bariatric Professional APH188 USER S MANUAL This product conforms to the standards of the Medical Directive 93 42 EEC as implemented by Legislative Decree 46 97 and s m e i...

Страница 2: ...2 1 HEAD PANEL 2 BED RAILS 3 Bar 3 HANDCONTROL 4 BED RAILS BUTTON 5 FOOT PANEL 6 WHEELS WITH BRAKE 7 HOUSING FOR LIFTING POLE ON BOTH SIDES 1 6 3 7 4 2 5...

Страница 3: ...safety warnings Pg 13 4 2 Hand control Pg 14 4 2 1 Hand control use Pg 14 4 3 Swivel wheels Pg 15 4 4 Lifting Pole Pg 15 4 5 Bed rails Pg 16 5 CLEANING AND DISINFECTING Pg 17 5 1 General information P...

Страница 4: ...ufacturer in order to avoid any faults This manual provides useful information to the buyer and to the end user on all the functions which will allow a safe and practical daily use of this bed Therefo...

Страница 5: ...is manual The manual may refer to the following groups of people somehow involved with using the bed Owner The owner for example suppliers of medical products dealers health care authorities etc can b...

Страница 6: ...rstand the instructions The safety symbol used does not replace the safety text it refers to It is always necessary to read the relevant safety warning in full and to follow it carefully 2 2 2 Safety...

Страница 7: ...ly disconnect the power plug from the wall clearly mark it as Damaged and deactivate the nursing bed Immediately inform the owner of the bed about this situation In chapter 6 1 you will find a checkli...

Страница 8: ...erification of tests see chapter 6 2 This bed can be used only according to the use conditions described in this manual Any other use is not to be considered as proper 2 3 2 Features Electric height a...

Страница 9: ...nded by 15cm simply by moving the foot panel outwards and the integral mattress support Bed Rails To protect patients from possible accidental falls from the bed the bed is equipped with rails meet cl...

Страница 10: ...s 3 1 Assembly Mounting instructions The assembly of the bed must be carried out by a minimum of two persons Unscrew the 8 hand screws on both the head and foot halves of the frame Use the bars provid...

Страница 11: ...stickers on the mounting points on the underside of the bed frame Equally the green stickers on the foot rest actuator should be matched up with the green stickers on the mounting points The main con...

Страница 12: ...terproof treatment It is possible to use the bed on tiles carpets laminated floors and linoleum A 230 volt power outlet correctly installed must be located as near as possible to the bed If there is t...

Страница 13: ...ssories on the electric bed make sure such accessories do not crush or cut the patient with sharp edges during the legs and backrest adjustments If this condition is not guaranteed the user must not p...

Страница 14: ...Press this button to change the angle of the leg support Backrest and leg support combined adjustment Auto Contour Press this button to change the angle of the backrest and the angle of the leg suppo...

Страница 15: ...e lifting pole must be inserted in the side from where the patient gets in or out of the bed to help him her out Only use the manufacturers lifting pole design for this bed and for specific Bariatric...

Страница 16: ...ositioned at the right distance to allow the rails to snap into place properly Make sure to use only the Apollo original bed rails supplied with the bed When using a bed with bed rails you must always...

Страница 17: ...t not be subjected to a water jet a high pressure cleaner or anything similar Cleaning should be done with a damp cloth If you suspect that water or moisture have entered into the electric components...

Страница 18: ...reading around These recommendations will help to prevent nosocomial infections If the beds are not immediately reused they should be stored away with a cover to protect from dust and accidental conta...

Страница 19: ...important role Do not use alcohol for large surfaces 6 MAINTENANCE Regulations The owners of the nursing beds in accordance with the applicable regulations in force are requested to guarantee the saf...

Страница 20: ...ble damages cable connection Power cord Possible damages cable connection Hand control Possible damages Visual inspection of mechanical components Lifting pole and its housings Possible damages deform...

Страница 21: ...the documentation of the inspection results must be carried out only by experienced personnel who know the proper way and conditions necessary to implement a correct testing The evaluation and the doc...

Страница 22: ...tion Visual inspection of electrical components Identification labels and stickers In place and clearly readable Housing of the control device Properly positioned damages Housing and lifting tubes of...

Страница 23: ...f the first measure ment Current actual value Result bed SK II type B 0 1 ma ma ma Protocol system for testing electrical medical devices Sheet 2 to 2 III Functional control ok not ok Problem descript...

Страница 24: ...s no This inspection protocol included Notes Tested on Examiner Signature Evaluated on Owner staff Signature 6 3 Spare parts Replacement parts are available From Apollo Healthcare Technologies Ltd by...

Страница 25: ...cement Dangerous for your life life threat due to electric shock Before starting any operations remove the plug from the wall outlet Any electrical equipment operations must be carried out only by qua...

Страница 26: ...lution The hand control and or the operating system does not work Power cord not connected Plug not under voltage Hand control plug not properly connected Faulty parts Insert the power cord Check the...

Страница 27: ...rol Type Ti Motion Electric motors for height adjustment of the mattress base and backrest and footrest Type Ti Motion TA7 Series Linear Actuators Max speed at no load full load mm s 38 23 2 8 3 Envir...

Страница 28: ...r and tear or due to excessive exposure to sunlight Damages caused by loss or spillage of liquids Damages from collisions or impacts against walls furniture etc Tears and accidental damages cigarette...

Страница 29: ...ctive 93 42 EEC and to national law no 46 97 and comply with the European Directive on CE marking in addition they are not measuring instruments they are not intended for clinical investigations they...