Performance
Operating Range
1 - 25 ft. (0.3 - 7.6 m) on liquids and hard, flat surfaces
1 - 10 ft. (0.3 - 3 m) on bulk solids
Analog Output
4-20 mA
Beam Pattern
9° off axis
Frequency
69
kHz
Response Time
0.6 - 3 seconds (dependent on output range)
Sample Rate
3 seconds @ 4 mA
0.6
seconds
@
20
mA
Accuracy
Accuracy ±0.25%
of
detected
range
Resolution
0.1
inch
(2.54
mm)
Environmental
Operating Temperature
-40 to 60°C (-40 to 140°F)
Internal Temperature Compensation
Yes
Enclosure
Protection
IP65
NEMA
rating
4X
Electrical
Supply Voltage (at sensor)
12-28 VDC
Current
Draw
22
mA
max
Output
Signal
3-30
mA
max
Load Resistence
150Ω max @ 12 VDC
600Ω max @ 24 VDC
Cable
Connection
2-terminal
connector
Masterials of Construction
Transducer
Housing
PVDF
(Kynar®)
Upper
Housing
PET