mPro400GC replaced by mPro400GCD
3
EN
3.7.2
mPro400GCD
Scenario
•
mPro400GCD-P/-M and mPro400GCD-S(H) are available.
•
Stack lights are added.
Fig. 3-13: Primary/Master controller mPro400GCD with Secondary controller mPro400GCD and stack lights
Conditions for new system layout
Procedure
Set up mPro400GCD-P/-M:
1. Use cable 544196-XXX to connect mPro400GCD-P/-M and the first stack light. Use following inputs
and outputs:
-
mPro400GC-P/-M: output X22
-
Stack lights: input
Arcnet in
2. Use cable 544196-XXX to connect additional stack lights.
3. Connect the System Bus Terminator 544197PT
to X32 at the
last mPro400GC-S.
4. Connect mPro400GCD-P/-M and mPro400GCD-S(H). See chapter 3.5 Install Primary/Master controller
with Secondary controllers mPro400GCD, page 11.
5. Start mPro400GC-P/-M.
6. Ensure that hybrid-capable software is used. The software has to be S168813-1.8.0 or newer.
7. Ensure that the current version of the operating system is used. The operating system has to be 2.7 or
newer.
Type
Indication
Software version
mPro400GCD-P/-M:
S168813-1.8.0 or newer.
mPro400GCD-S: S168025-510
Operating system
2.7
Cables
mPro400GCD-P/-M to mPro400GCD-S(H).
TSnet Cable: Part number 962037-XXX
mPro400GCD-P/-M to stack lights.
System Bus Cable: Part number 544196-XXX
System Bus Terminator
Only required for stack lights: Part number 544197PT
mPro400GCD-P/
mPro400GCD-M
mPro400GCD-S(H)
mPro400GCD-S(H)
544196-XXX
544196-XXX
544196-XXX
962037-XXX
962037-XXX
X21
X22
X22
X21
544197PT
X22
Arcnet
Arcnet
Arcnet
TSnet
TSnet
Arcnet
in
Arcnet
out
Arcnet
in
Arcnet
out
Arcnet
in
Arcnet
out
Содержание Cleco mPro4000GC