mPro400GC replaced by mPro400GCD
12
P2434JH | 2019-08
Apex Tool Group
3
EN
Procedure
Set up mPro400GCD-P/-M:
1. Use cable 962037-XXX to connect mPro400GCD-P/-M and mPro400GCD-S(H). See documentation
P2300HW or P2309HW.Use following inputs and outputs:
-
mPro400GCD-P/-M: output X21
-
mPro400GCD-S(H): input X22
2. Use cable 962037-XXX to connect additional mPro400GCD-S(H) to the previous mPro400GCD-S(H) if
necessary. Use following inputs and outputs:
-
Previous mPro400GC-S: output X22
-
Following mPro400GC-S: input X21
3. Start mPro400GCD-P/-M.
4. Ensure that hybrid-capable software is used. The software has to be S168813-1.8.0 or newer.
5. Ensure that the current version of the operating system is used. The operating system has to be 2.7 or
newer.
Install Secondary controllers:
1. Select
Navigator > Tool Setup > Install
.
→ The
Assign Tool
dialog opens.
2. The following settings are required:
3. Confirm with <OK>.
The TSnet cable may not be connected to the infrastructure network.
Home network
mPro400GCD-P/
mPro400GCD-M
mPro400GCD-S(H)
Parameter
Description
Group Name
Select tool group. It is possible to select up to 16 tool groups.
Name
Assign a name to the Secondary.
Type
Select
Secondary
.
Содержание Cleco mPro4000GC