Section 1 - Introduction

 

 

1.1    Introduction   

 

 

Congratulations on purchasing an 

APEL 

product.    It’s an important and very smart   

decision that’s sure to reward you for many years to come.    To ensure that you take   
full advantage of our Bilirubin meter, 

BR-5000N

’s offered features and warranty 

benefits, be sure to carefully read and fully comprehend this Operation Manual.     
It is designed to acquaint you with the features and help you effectively operate the 
new instrument in safety.    We sincerely hope you will enjoy many benefits of being 
associated with our product which represents both quality and customer satisfaction.   
We are proud of the advanced engineering and quality construction of each instrument 
we build.    If you have any questions, please contact your supplier and refer to the 
model number and 

seven-digit serial number

 located at the back of your unit, when 

inquiring. 
 
The BR-5000N Bilirubin meter is a digital, direct reading measuring equipment 
developed with the purpose of enabling the measurement of total bilirubin in serum   
of neonate while compensating for hemolysis, turbidity, and other components of 
obstruction.    With the BR-5000N, an alarm is displayed automatically whenever 
there is a high-density specimen or a high level of obstruction that falls outside the 
tolerance. 
 

 

 
 
 

1.2    Features   

 
1. Handles hemolysis and turbidity easily 
    Careful selection of the dual wavelength color filters and the combination of   
    electronic technology minimize the interference of hemolysis and turbidity. 
 
2. Easy operation 
    Microprocessor enables the Auto Calibration and easy operation.    And after the     
    equipment is calibrated with a standard solution, you can measure specimen     
    without using the standard solution after that. 
 
3. Easy set of the sample tube 
    A serum gauge is provided on the surface of BR-5000N, which indicates the     
    proper sample volume to be inspected. Only simple action is required to set the       
    capillary tube into the holder. 
 
4. Alarm lamp informs user of abnormalities 
    Alarm lamp signals either abnormal value or situations such as burned out of   
    the bulb, bilirubin concentration of 30mg/ 

or more, or high hemolysis of     

    250mg/

  or more. 

 

Содержание BR-5000N

Страница 1: ...please read this manual carefully and retain it for future reference Failure to read understand and follow the instructions in this manual may result in damage to the unit injury to operating personne...

Страница 2: ...or 7 Section 3 Operation procedure 3 1 Preparation 8 3 2 Taking blood sample 8 3 3 Measurement of the specimen 10 3 4 Setting the name or ID number of the test 12 3 5 Other functions 12 3 6 How to use...

Страница 3: ...oped with the purpose of enabling the measurement of total bilirubin in serum of neonate while compensating for hemolysis turbidity and other components of obstruction With the BR 5000N an alarm is di...

Страница 4: ...to computer by serial interface The measurement data can be sent to computer through RS 232C interface 7 mg and mol indication One of mg and mol indication can be selected by the control panel 8 Easy...

Страница 5: ...on stable cart stand or table 7 If stored in non room temperature setting allow the unit to reach room temperature before turning on Do not place this instrument in an environment where there is seve...

Страница 6: ...refer to your supplier under the following conditions When the power cord or plug is damaged and or frayed If the unit has been directly exposed to water or liquid If the instrument displays unusual...

Страница 7: ...nance repair or service work In the event of missing parts defects damages or other problems immediately contact your supplier Make sure that your carton contains the following items Main Unit Quantit...

Страница 8: ...mp 8 Fuse holder 3 Control panel 9 AC Power socket 4 Serum gauge 10 Printer Interface Connector D sub25p female 5 Capillary tube holder 11 RS 232C Interface Connector D sub9p male 6 Serial number labe...

Страница 9: ...le from neonates warm the tip of the big toe the heel of the foot or wherever blood is to be drawn to get the blood flowing well Taking the blood sample within 2 hours after suckling or taking meal ma...

Страница 10: ...serum part A serum gauge is provided on the surface of BR 5000N Fig 2 1 Fig 2 2 Fig 2 3 Fig Fig 4 1 Fig 4 2 Top of the big toe or heel of foot Capillary tube Capillary tube Blood Blood Capillary tube...

Страница 11: ...ys can be stored and can be controled with them Measured data are stored up to 100 until the power switch is turned off For example if the samples of 10 babys are measured 10 data per baby can be stor...

Страница 12: ...ng of the printer 1 Auto print at each measurement Turn on the Auto printer SET 5 Refer to 3 5 3 2 Manual operation of printing right after the measurement Press PRINT after a data is measured 3 Print...

Страница 13: ...urement SET 0 Standard CONC 10 0 30 0 mg SET 4 Printer Use 1 on 2 off SET 5 Auto Print 1 on 2 off SET 6 Comm RS 232C 1 on 2 off SET 7 Baud rate 1 9600 2 19200 3 34800 bps SET 8 RS 232C mode d Data bit...

Страница 14: ...ixed and memorized Display comes back to Ready without memorizing the data when EXIT key is pressed Even when the Auto print is off the measured data can be printed out after the measurement with PRIN...

Страница 15: ...ion is fixed and memorized Display comes back to Ready without memorizing the data when EXIT key is pressed 3 5 7 Deletion of data You can delete the stored data for the designated ID_No And SN _ come...

Страница 16: ...the thumb touching the right side of the gauge 3 Lift up the capillary tube as it is and insert it into the capillary holder until the thumb touchs the top of the capillary holder 4 Then the slit of...

Страница 17: ...ed To use with BR 5000N Empty the standard solution into a larger container Add 6m of distilled or deionized water and dissolve the standard solution again Assay value 1 3 concentration standard is ob...

Страница 18: ...ower cord into electrical wall outlet and the unit securely LCD display and or LED does not glow when the power switch is turned on 2 DC power suply has some troubles 3 Certain cables inside are not s...

Страница 19: ...Disconnect the lamp connector fig7 4 Turn the light bulb counterclockwise toward the bulb and remove it Do not touch the bulb by your fingers directly but hold it with a cloth fig8 5 Replace the bulb...

Страница 20: ...ntainer Hematocrit capillary tube Heparinized Light source 5V 0 75Atungsten lump Detector Silicon photocell Display LCD Display 16 rows 2 lines Power requirements 100 240 50 60 10VA Dimensions 280mm 2...

Отзывы: