background image

Positive high voltage amplitude

正高压幅值

Negative high voltage amplitude

time

The negative ion output increases with the 

increase of negative high voltage amplitude

The negative ion output increases with the 

decrease of negative high voltage amplitude

Adjust ion balance voltage

Vp

Vp

Vp

Vp

Vn

Vn

Vn

Vn

Adjust the output frequency of 

positive and negative high voltage

The output frequency of positive and 

negative ions increases

The output frequency of positive 

and negative ions decreases

time

-HV

(Negative high voltage)

The output ratio of positive and negative ions is adjustable, which can be used to 

adjust the ion balance voltage

.

The output frequency of positive and negative ions is adjustable, which can be 

applied to different discharge distance to achieve faster discharge speed

.

+HV

 voltage)

(Positive high

Positive voltage working time

Negative voltage working time

-HV

(Negative high voltage)

+HV

(Positive high voltage)

Positive voltage working time

Negative voltage working time

time

-HV

(Negative high voltage)

+HV

(Positive high voltage)

-HV

(Negative high voltage)

+HV

(Positive high voltage)

Positive voltage working time

Negative voltage working time

Positive voltage working time

Negative voltage working time

-HV

(Negative high  voltage)

+HV

(Positive high voltage)

-HV

(Negative high  voltage)

+HV

(Positive high voltage)

+HV

(Positive high voltage)

+HV

(Positive high voltage)

-HV

(Negative high  voltage)

-HV

(Negative high  voltage)

Positive high voltage amplitude

Positive high voltage amplitude

Negative high voltage amplitude

Negative high voltage amplitude

Negative high voltage amplitude

Adjust ion balance voltage

time

time

time

Adjust the output frequency of 

positive and negative high voltage

time

time

Ion balance/

ion output frequency adjustable

Intelligent Control

Содержание AP-AB1215

Страница 1: ...AP TR Shanghai Anping Static Technology Co Ltd High Efficient Electroshock proof Intelligent Ion Bar AP AB1215 AP T...

Страница 2: ...nics optoelectronics semiconductor and other industries Effectively solve the problem caused by static electricity Prevent adhesion of objects Static removal Prevent uneven scattering Control ink spla...

Страница 3: ...High efficient Safe Static removal...

Страница 4: ...e speed HV voltage Positive high Positive voltage working time Negative voltage working time HV Negative high voltage HV Positive high voltage Positive voltage working time Negative voltage working ti...

Страница 5: ...o restore the set time The cleaning function becomes invalid if the value is set to 0 days Adjust frequency FREQ Press FREQ first then press to increase or decrease the frequency of positive and negat...

Страница 6: ...pressure HV Negative high pressure The pulsed AC method alternately applies and high voltage to one electrode needle to generate two polar ions Compared with the AC method the ion generation efficienc...

Страница 7: ...2 2 75 0 0 5 1 0 9 9 150 6 0 5 4 21 3 Test diagram 30mm 150mm 0s 0s 0 1s 1 0s 1 7s 3 2s 3 1s 5 1s 2 8s 3 1s 2 3s 6 0s 150mm 50mm 70mm 100mm 150mm 150mm Flat tester Test Conditions Ion bar length 410m...

Страница 8: ...nvironments Electroshock proof Protection against electroshock Working status visualization Red light alarm when high voltage abnormal CE certification It can effectively prevent the external electrom...

Страница 9: ...head cross bolt with flat spring pad Ion bar size drawing Mounting bracket size drawing Product Size Product Details Specification Details Parameter Size Negative high voltage orange light on when wo...

Страница 10: ...30V AVE Discharge speed 1S Test distance 100mm Status indicator Green light normal Blue light standby Blue light flashing debugging cleaning Red light Abnormal high voltage Working temperature 0 50 W...

Страница 11: ...adapter power indicator light is on and the ion bar panel indicator light is green to show that the ion bar is working The positive and negative high voltage indicator lights alternately h with the fr...

Страница 12: ...5 200 1 250 Installation position 2 The ion bar grounding electrode is not allowed to be covered by other objects 3 It is advisable to install two ion bars side by side with an interval of more than...

Страница 13: ...idden to use this equipment in flammable and explosive environments 5 Unauthorized disassembly of the product is strictly prohibited internal maintenance and repair must be performed by professionals...

Страница 14: ...ance index is normal Maintenance NO Faults Reasons Solutions 1 The RJ45 power port indicator on the front panel is off Poor contact of the power cable Power supply mismatch Check whether the power cab...

Страница 15: ...g analysis and elimination solution provider Speciality Creates Value AP T Shanghai Anping Static Technology Co Ltd Tel 86 21 64517676 Fax 86 21 64517673 Postcode 200233 Website www ap static com Addr...

Отзывы: